Loreme CPL165 Configuration

Measurement unit for distribution panel

Advertisement

Quick Links

Measurement unit for distribution panel (DPM)
Wattmeter, Energy meter for multi electrical feeders
UTILIZATION AND CONFIGURATION
CPL165
LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3
Phone 03.87.76.32.51 - Telefax 03.87.76.32.52
Contact : Commercial@Loreme.fr - Technique@Loreme.fr
Download manual at : www.loreme.fr
REV 0.5 - 28/10/16
E 1

Advertisement

Table of Contents
loading

Summary of Contents for Loreme CPL165

  • Page 1 Wattmeter, Energy meter for multi electrical feeders UTILIZATION AND CONFIGURATION CPL165 LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact : Commercial@Loreme.fr - Technique@Loreme.fr Download manual at : www.loreme.fr...
  • Page 2: Table Of Contents

    WEB SERVER ................................p22 1) WEB page presentation ..........................p22 2) Procedure to reset the energy meters ....................p23 WIRING ..................................p24 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 3: Device Presentation

    TABLE OF CONTENTS Device Presentation The CPL165 is a complete and very compact measuring unit for power consumption measurement (building manage- ment, workshops, data centers, ..) in an energy efficiency approach. The Ethernet link allows measures supervision while ensuring easy and fast integration into existing networks. The inter- nal bus allows multiple modules focused on Ethernet.
  • Page 4: Visualization

    (sum of powers P1F, P2F, P3F and sum of the energies W1F,W2F, W3F). 2) CONFIGURATION The CPL165 can be configured entirely by the front panel. Pressing the button 'Config' allows access to the configura- tion. The device display’s the following message: CONFIGURATION ver 0.5...
  • Page 5: Current Inputs Configuration

     TABLE OF CONTENTS 2.3) Current inputs configuration  MEASUREMENT? Press the ‘ ’ (Yes) button to access the rubric.  (Y-N) Press the ‘ ’ (No) button to skip the rubric. CONF. I CHANNEL? It is possible to set the rated current for a particular channel by selecting <ONE> <ONE>...
  • Page 6: Energy Meters Start Value Configuration

    (only alphanumeric characters are accepted: '0' to '9' and 'A' to 'Z'). Note: When the function is activated by answering YES, a new code is automatically requested. LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 7: Rs232 Link Setting

    Step 2: Setting of terminal emulation software (PC with windows). The terminal emulation software for PC « HyperTerminal » is resident in windows up to XP version. For later ver- sions, it is downloadable on : www.loreme.fr in download part ( http://www.loreme.fr/HyperTerm/htpe63.exe =>...
  • Page 8: Terminal Mode

    Previous choice = NO: - pressing <N> or "Enter" => choice validation = NO. - pressing <Y> => choice changing = YES. LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 9: Language

     TABLE OF CONTENTS 2.1.3) Value acquisition Example: RATED CURRENT 32 A There are two possibilities: - The validation without modification by pressing the <Enter> key, - The modification with simultaneous display followed by validation with the <Enter> key. Remarks: - It is possible, when a mistake is made during a value acquisition, before validating it, to go back by pressing on <backspace>...
  • Page 10: Communication

    19.2 kbauds (Y-N)YES 2.5) Energy ENERGY ? (Y-N) Press <Y> to access the rubric. (Continued on next page) E 10 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Techni-...
  • Page 11: End Of Configuration

     TABLE OF CONTENTS CHANNEL W1A 0.02 KWh To change the counter value of a particular channel, you must enter the phase 0,1A,3F,2B.. W1B 0.48 KWh number and the channel name. Press <Enter> to confirm the selection. <ENTER> W1C 0 KWh ->...
  • Page 12: Firmware Update

    FIRMWARE LOADER Rev2.3 READY TO TRANSFER... The device is now in the firmware load mode and is waiting for the firmware file. This file is provide by LOREME and contain the firmware code in Intel HEX format. Select the « Transfer », « Send a text file ... » in the HyperTerminal menu.
  • Page 13: Emc Consideration

    1) Introduction To meet its policy concerning EMC, based on the Community directives 2014/30/EU & 2014/35/EU, the LOREME company takes into account the standards relative to this directives from the very start of the con- ception of each product. The set of tests performed on the devices, designed to work in an industrial environment, are made in accor- dance with IEC 61000-6-4 and IEC 61000-6-2 standards in order to establish the EU declaration of confor- mity.
  • Page 14: Bus 100 System

    Reserved address for a Reserved address for a device identification code device identification code device identification code Reserved address for later use. E 14 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Techni-...
  • Page 15: Modbus Tcp Communication

    2) Communication Measures are refreshed every 2 seconds. The CPL165 supports to be questioned by several Modbus TCP masters (maximum 6). The response time to a request is about 20ms, it is strongly influenced according to the network traffic. Excessive load can cause communication errors (response time of the slave exceeded (timeout), ..).
  • Page 16: Measures Tables

    5) Measures Tables The tables show the addressing of the CPL165/CMTCP (bus address = 0). To know the address of the other modules on the bus, it is necessary to add an offset corresponding to 1000 x the location of the module on the bus100.
  • Page 17  TABLE OF CONTENTS Decimal word address Designation Total (Hexadecimal) Words 31 ($001F) Energy 1D (kWh x 100) Word 1 Word 2 33 ($0021) Energy 1E (kWh x 100) Word 1 Word 2 35 ($0023) Energy 1F (kWh x 100) Word 1 Word 2 37 ($0025)
  • Page 18 Power 3F (W x 100) Word 1 Word 2 99 ($0063) Energy 3A (kWh x 100) Word 1 Word 2 E 18 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Techni-...
  • Page 19  TABLE OF CONTENTS Decimal word address Designation Total (Hexadecimal) Words 101 ($0065) Energy 3B (kWh x 100) Word 1 Word 2 103 ($0067) Energy 3C (kWh x 100) Word 1 Word 2 105 ($0069) Energy 3D (kWh x 100) Word 1 Word 2 107 ($006B)
  • Page 20: Modbus Communication

    6) RS485 bus wiring The CPL165 have a 4-pin connector to facilitate the networking of the devices. A switch activates the terminating resis- tor. (this resistance limits the reflections on the RS485 line. It should be only activated at each end of the bus).
  • Page 21: Snmp

    2) Use The CPL165 is a SNMP v1 agent. The supervisor can read all the measures made by the device: - Measures for phase 1 (voltage, currents, phi cosines, powers and energies), - Measures for phase 2 (voltage, currents, phi cosines, powers and energies), - Measures for phase 3 (voltage, currents, phi cosines, powers and energies), - Measures total (powers and energies per channel).
  • Page 22: Web Server

    It is therefore essential to run a scan if ever the constitution of the bus has changed (adding or removing a module). E 22 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Techni-...
  • Page 23: Procedure To Reset The Energy Meters

     TABLE OF CONTENTS 2) Procedure to reset the energy meters Simply select the channels you want to clear and click on the button « Reset W..». Individual selection of channels in the group. Selection of all the chan- Button to reset the nels in the group.
  • Page 24: Wiring

    When a current input is not used, it is preferable to short-circuit it to avoid misleading in the calculation of powers / energies. E 24 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Techni-...
  • Page 25  TABLE OF CONTENTS CPL165 connection with DATA CENTER BOX PLC 1 kohms RS485 bus to Male DB9 CPL165 connector to PLC 1 kohms E 25...

Table of Contents