Madell Technology, Corp. Contents 1. General ······················································································· 4 Main Technical Characteristics ················································ 4 3. Instructions for Installation and Operation······························ 5 Unpack to Check and Accept Equipment··············································· 5 3.2 Points for attention for installation ························································ 5 3.2.1 Location ································································································ 5 3.2.2 Environmental conditions ··································································· 5 3.2.3 How to Install the Machine ··································································...
Page 3
Madell Technology, Corp. 7. Contact Us················································································ 22 Madell Technology, Corporate Office, 1141 E Philadelphia Street, Ontario, CA 91761 t. 877-670-9023 f. 909-418-6956 www.madelltech.com Website: ; Technical Service Email: info@madelltech.com...
China. The mini fully automatic reflow soldering machine TYR108C is an economic and practical model, which is finely designed and developed based on the Madell Technology’s technicians’...
If there are issues found from the above check, do not install the machine, and contact our company as soon as possible. 2. Check the model number of the reflow soldering machine Beijing Madell Technology Corp. TYR108C 3.2 Points for Attention for Installation 3.2.1 Location Do not install the machine at a location with powder, corrosive gas, moisture, rain attack, high temperature, electromagnetism, high-frequency pulse interference, vibration, and/or shock etc.
Madell Technology, Corp. with that specified for this machine, and connect reliably the grounding wire of the power plug of this machine with the grounding device. It is also required that the power socket be grounded reliably, otherwise electric leakage from the equipment may occur (sparking may occur). If encountering this situation, stop installation at once and check if the power socket is grounded reliably.
Madell Technology, Corp. program, and press this key twice at initial state, you can change PTN value, 1-8 selectable; C. UP key [▲]: Used to select a mode at mode selection menu; and used to increase a value at parameter setting state; D. DOWN key [▼]: Used to select a mode at mode selection menu; and used to decrease a value at parameter setting state.
Page 8
Madell Technology, Corp. Thus, a target temperature has been set. The following setting for all of the temperature segments has the same meaning and method as those in steps 5-7, only the set values are different based on your requirements. The cycle is repeated until all of the selected program segments (i.e.
Madell Technology, Corp. aON2 [⌒]↓↑[A/M] aOF2 denotes when the second group of alarm stops at this segment; ‘m’ is the set time value when the alarm stops at this segment, and the unit is aOF2 second, but minute for the carry digit from 60. We generally set ‘m’ as the cooling time at the last segment minus 2 seconds (in general, 2.58 for leaded and 3.28 for lead-free;...
Madell Technology, Corp. requirement for the curve (e.g. the target value is 130° C, the previous target value is 100° C, and the temperature rise requirement is 1-2° C/s, then we can calculate the time needed from 100° C to 130° C, i.e. (130-100)/(1 to 2), the average is about 18s.) Similarly for the setting of other segments.
Page 11
Madell Technology, Corp. 2. Turn on the power switch of the reflow soldering machine, and click to connect software, thus the software automatically enters Run Polling mode; at this moment, every control button turns grey, and they change to valid after being clicked. At this moment, if no resetting of curve is needed, click Run directly to run the software.
Madell Technology, Corp. If click Analyze, an indication box will be displayed on the upper right corner as shown in the following picture. At this moment, click and drag the zero point, the relative humidity, running time and temperature rise slope etc. of the point where the mouse pointer is located will be displayed in the indication box.
Madell Technology, Corp. Initial Temperature: Used to set a temperature at which the timing and running starts for curve running, generally room temperature 25-30° C. RPT Number of Repeated Running Times: Number of cycles for once to press Run button, generally 1.
Page 14
Madell Technology, Corp. Madell Technology, Corporate Office, 1141 E Philadelphia Street, Ontario, CA 91761 t. 877-670-9023 f. 909-418-6956 www.madelltech.com Website: ; Technical Service Email: info@madelltech.com...
Madell Technology, Corp. 4.4.6 PID Setting: This option is for machine adjustment by engineering designers, so the end users must not conduct this option. Thanks a lot! 4.4.7 High Level Setting: This option is for machine adjustment by engineering designers and some functions are being perfected, so the end users must not conduct this option.
Madell Technology, Corp. 4.5 Description of Temperature Curve The control of temperature curve is critical to ensure soldering quality. The temperature curve is soldering past melting curve, which consists of five processes: temperature rising process → temperature keeping process → rapid temperature rising process → soldering process → cooling process.
Madell Technology, Corp. the set temperature and the actual temperature, and the set temperature is slightly lower than the actual temperature. Due to the heat transfer of machine, the temperature difference at the beginning is larger than that after one hour of running. 5.
Madell Technology, Corp. cooling time can be set according to the practical needs; in general, it is set as 3 minutes for leaded soldering and 3.30 minutes for lead-free soldering; see the above programming method for details. The air duct is designed as normally closed, and it is controlled by the temperature control system for open/close and is automatically opened for cooling based on the practical needs.
Page 19
Madell Technology, Corp. reflow soldering machine. No impact to the probe on the top of the sensor is permitted. The probe part shall be wiped slightly and routinely with cotton ball soaked with absolute alcohol to avoid remaining dirt that will impact the normal operation. C.
Page 20
Madell Technology, Corp. there is electrical continuity between two contacts at high voltage side. If yes, replace the relay. If not, please contact the technicians in Madell Technology. E. After the power switch is tuned on, there is no display or the fan does not run: Check whether the power supply is turned on.