T3 Innovation Power Prowler PLR600 Quick Start Manual

3-in-1 dmm/tdr cable fault finder for energized or unenergized cables 600v cat iii

Advertisement

Power Prowler
3-In-1 DMM/TDR Cable Fault Finder
for Energized or Unenergized Cables
Quick Start Guide
600V CAT III
For Live
Energized Cables
PLR600
www. T 3Innovation.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Power Prowler PLR600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for T3 Innovation Power Prowler PLR600

  • Page 1 Power Prowler ™ 3-In-1 DMM/TDR Cable Fault Finder for Energized or Unenergized Cables Quick Start Guide 600V CAT III For Live Energized Cables PLR600 www. T 3Innovation.com...
  • Page 2 “Soft” key functions are defi ned on the display above each button. Back Test Direction cursors to Enter move in LCD display On/Off Banana Jacks 600V CAT III Dual Banana BNC to Meter Test Leads to BNC Female Alligator Clips 600V CAT III Power Prowler Quick Start Guide...
  • Page 3: Safety Information

    • Always wear personal protective equipment when working with the Power Prowler. It is recommended to use caution when handling the probes and cable connections on the Power Prowler™ when the Voltage! Icon is present. T3 Innovation...
  • Page 4 Digital Multi Meter (DMM) • Power on the Power Prowler. • Use the left or right arrow buttons to highlight the DMM icon, then press enter or use the DMM soft key • Use the left and right arrow buttons to select VDC, VAC, LoZ VAC, Continuity, or Ohms.
  • Page 5 +50ft and -50ft until the length of the cable is displayed. Press the test button discover the VOP or press the cancel soft key to cancel. T3 Innovation...
  • Page 6 How to Perform a Fault Location Test (Cont’d) Note: See Power Prowler Settings for instructions on how to select if a leader cable is or is not being used. The leader cable icon is displayed on the top left of the screen when the leader cable is in use. •...
  • Page 7 To select ft/m and Leader/No Leader, use the up or down buttons to highlight the ft/m option . Use the left or right buttons to select the desired option. For additional instructions please visit www.t3innovation.com/powerprowler to download the Power Prowler instruction manual. T3 Innovation...
  • Page 8: Quick Start

    Power Prowler ™ Quick Start • Power Prowler Main Unit • Meter Test Leads 600V CAT III • BNC (F) Double Banana Plug PLR600 • BNC (M) to F Connection (F) • BNC (M) to Alligator Clips • Hanging T3 Pouch Optional Accessories Part Number Description...

Table of Contents