INSTALLATION AND SERVICE MANUAL C7 SERIES CONTINUOUS DUTY POWER AMPLIFIER RACK OF C7 AMPLIFIERS December 20, 2015 Crescend Technologies Tel: 847 908 5400 140 E. State Parkway Fax: 847 908 5408 Schaumburg, IL 60173 Email: sales@CrescendTech.com Web Site: www.CrescendTech.com Copyright Crescend Technologies...
Location of Status Indicators Initial Start-Up Section 4 Principles of Operation Introduction RF Input Signal RF Output Load Functional Description 4.4.1 Main RF Path 4.4.2 Loop Control 4.4.3 VSWR Protection 4.4.4 Thermal Protection Amplifier Cooling Copyright Crescend Technologies 040003A005 Rev 1...
Page 3
List of Illustrations Figure C7 Series Single Amplifier, Front View C7 Series Single Amplifier, Rear View FPR-5 Rack, Front Right View C7 Series Amplifiers in Rack, Rear View C7 Series Status Indicators, Front Panel Amplifier Test Setup diagram List of Tables Table...
1.2. PRODUCT DESCRIPTION The Crescend Technologies C7 Series of RF power amplifiers are designed for trunking and conventional repeater applications. Rack mountable and designed to accept a range of input powers for a given rated output power, each amplifier covers a broad range of frequencies without retuning.
Figure 1-2. C7 Series Single Amplifier, Rear View 1.3. FUNCTIONAL AND PHYSICAL SPECIFICATIONS Functional and physical specifications for the C7 Series amplifiers are listed in Tables 1-1 and 1-2. 1.4. EQUIPMENT CHANGES Crescend Technologies, Inc. reserves the right to make minor changes without notice, including, but not necessarily limited to, component substitution and circuitry changes.
Table 1-1. C7 Series Amplifier Functional Specifications Frequency Range: See Table 1-2 (Range Set at Factory) Operating Voltage: +13.8 ±0.7 Vdc Current Consumption: See Table 1-2 Duty Cycle: 100% Power Input: See Table 1-2 (Range Set at Factory) Power Output (Single Carrier Operation):...
<-70 5-10 10-20 20-50 NOTES: Manufacturer’s Rated Output Power of this Equipment is for Single Carrier Operation. All specifications above apply at +13.8 ± 0.1 VDC operating voltage, ambient temperature of 25°C ± 5°C. Copyright Crescend Technologies 040003A005 Rev 1...
INTRODUCTION This section contains installation recommendations, unpacking, inspection, and installation instructions for the C7 Series of amplifiers. Carefully read all the material in this section prior to equipment unpacking or installation. Also read and review the operating procedures in Section 3 prior to installing the equipment. It is important that the licensee perform these tasks correctly and in good faith.
2. Keep DC wires as short as possible to minimize inductance induced voltage transients. 3. Size DC Wires properly to handle the load current to minimize voltage drop. Figure 2-1. FPR-5 Rack, Front Right View Copyright Crescend Technologies 040003A005 Rev 1...
Figure 2-2. C7 Series Amplifiers in Rack, Rear View 2.5. AMPLIFIER SUMMARY ALARM The summary alarm connections is made through a filtered feedthrough connector on the rear of the amplifier (see Table 2-1). Table 2-1. Summary Alarm Connection APPROPRIATE FUNCTION...
The location and function of the C7 amplifier status indicators and is shown in Figure 3-1 and described in detail in Table 3-1. Figure 3-1. C7 Series Status Indicators, Front Panel Table 3-1. C7 Series Amplifier Status Indicators STATUS LED...
4. Turn on external exciter/transceiver and apply RF input signal. The fan should turn on after approximately 3 seconds. 5. Turn off RF input signal. The fan should continue running, but turn off after approximately 6-8 seconds. Copyright Crescend Technologies 040003A005 Rev 1...
PRINCIPLES OF OPERATION 4.1. INTRODUCTION This section contains principles of operation of the C7 Series of RF Power Amplifiers. 4.2. RF INPUT SIGNAL The amplifiers are set at the factory to work over different input power ranges. The available range of inputs for different frequency ranges may be found in Table 1-2.
Replace immediately with a similar to insure long term reliability. Heat is one of the biggest factors in reducing the reliability of your amplifier. Make sure the fan has access to cool and clean airflow within the rack. Copyright Crescend Technologies 040003A005 Rev 1...
Table 5-2 and the test setup is shown in Figure 5-1. Watt Meter Watt Meter Power Supply Signal Coupler Coupler Attenuator Spectrum Generator Amplifier 30 dB Analyzer Figure 5-1. Amplifier Test Setup Diagram Copyright Crescend Technologies 040003A005 Rev 1...
To ensure safe shipment of the amplifier, it is recommended to use the packaging designed for the amplifier. The original packaging material is reusable. If it is not available, contact Crescend’s Customer Service Department for packing materials and information. Copyright Crescend Technologies 040003A005 Rev 1...
Need help?
Do you have a question about the C7 SERIES and is the answer not in the manual?