iRelay 460 Equipment Installation Guide Part Number: UGD-D01035 Revision: 1.0 Published: September 2015...
Page 2
Information supplied by Airspan Networks Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Airspan Networks Inc. for the use thereof nor for the rights of third parties which may be effected in any way by the use of thereof.
Document Conventions ..................2 Document Organization ..................3 Related Reading ....................3 Customer Service Help Desk ..............4 Airspan Encourages Comments ................4 1 Introduction ..................5 1.1 iR460 with Internal Steerable Antenna Assembly ........... 5 1.2 Installation Workflow ..................6 1.3 Installation Checklist ..................
Page 4
3.5 Mounting with AirHarmony 4000 ..............26 A Job Sheet ..................27 B Installation Checklist................30 C Initial Site Survey ................31 D RFI Checklist ..................33 E Standard Torque Values – Metric System ......... 35 F Abbreviations ..................37 UGD-D01035 Airspan Commercial and Internal Use...
Page 6
Table 10. Weights and Dimensions of Products and Brackets ............11 Table 11. Weights and Dimensions of Brackets ................... 11 Table 7. Parts List ..........................13 Table 8. Surge Protection Specification ....................22 Table 9. Network Configuration Information ..................29 UGD-D01035 Airspan Commercial and Internal Use...
Document Information Abstract This document details the procedures for installing the iRelay (iR460) equipment and includes equipment installation best practices. Airspan assumes that the personnel performing these instructions have a basic working knowledge of the equipment. Revision History Revision Details...
• Connecting and managing cables • Intended Audience This guide is intended for the personnel who install the iR460 equipment. Airspan assumes that a person performing these instructions is qualified in performing installations and capable of identifying hazards. Document Conventions This document uses the following typographic conventions.
Lists the abbreviations (used in this document) and their G Abbreviations expansions. Related Reading The following document contains related information: • iRelay 460 Product Specification This product specification describes the design requirements and standards of iR460. UGD-D01035 Airspan Commercial and Internal Use...
Customer Service Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form.
Provides PtP connectivity. • Functions as the building blocks that provides fully secure and encrypted capabilities. • Provides a trusted wireless backhaul solution that supports all capacity needs of Airspan’s • eNodeB. Provides high-speed data. •...
Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements.
AC input), see the iRelay 460 Configuration Guide (Rev 1.0). Table 4. iR460 Installation Parts and Kits Product Part Code Item Description Quantity per Install IR460-xxxx-xxx-xx iR460, single Ethernet, PoE input iR460 unit POE supported from AirHarmony* POE+ UGD-D01035 Airspan Commercial and Internal Use...
19 mm iRelay pole bracket front 4.17 inch / 5.63 inch / 1.50 inch / 2.02 lbs / 915g and rear parts (for poles 106 mm 143 mm 38 mm up to 3.7 inch diameter) UGD-D01035 Airspan Commercial and Internal Use...
(for poles over 106 mm 143 mm 38 mm 3.8 inch diameter) 2.2 iR460 Assembly Figure 3 Figure 4 show the gap required between iR460 and the mounting pole. Figure 3: Product Dimension Envelope (Wall Mounted) UGD-D01035 Airspan Commercial and Internal Use...
For a description of these parts, see Table Figure 5: iR460 Mounting Kit Parts Table 9. Parts List Item Quantity Description Long bolts for connecting mounting bracket front and back plates together around the small pole UGD-D01035 Airspan Commercial and Internal Use...
Torque = Make sure to place part A behind the pole. Figure 6: Mounting Bracket 2. Slide iR460 into the pole bracket front slot. UGD-D01035 Airspan Commercial and Internal Use...
3. Make sure the bracket mounting holes are aligned and secured with the short bolts. Figure 9: Securing the iR460 Unit 2.3.1.2.1 Torque Setting for Small Poles Torque setting for an M8/20 SEM should not exceed 18 lb ft or 25 Nm. UGD-D01035 Airspan Commercial and Internal Use...
Figure 11: Front View of the iR460 Mounting Plate 2. Slide iR460 into the front slot of the pole bracket. Figure 12: Sliding the iR460 Unit UGD-D01035 Airspan Commercial and Internal Use...
2.3.1.4 Mounting Type B iR460 for Wood Poles Greater than 3.75 inch Diameter (TBC) 2.3.1.5 Mounting the iR460 Panel Antenna Unit on a Wall For wall mounting, perform the following steps: 1. Attach the mounting bracket to the wall using three fixings. UGD-D01035 Airspan Commercial and Internal Use...
460 Equipment Installation Guide Figure 15: Attaching the Mounting Bracket Note: Airspan does not supply the screws. Depending on the wall material, choose appropriate screws. UGD-D01035 Airspan Commercial and Internal Use...
Figure 17). Note: Airspan does not supply the clamp required for this connection. Depending on the tower structure, choose an appropriate clamp. Figure 17: Attaching the Earth Cable to the Pole Important: To avoid or minimize galvanic corrosion, when installing a protection earth be sure to use the suitable metal combinations.
Additional surge protector device can be positioned at the building entry point and grounded properly, as illustrated in the figure below. Airspan recommends to avoid positioning iR460 at the highest point on a structure (for example—the roof of a building, telecoms mast or tower). Ideally you should position the iR460 unit within a lightning protected zone.
Improperly grounded connections are also a source of noise that can cause a sensitive equipment to malfunction. To limit the equipment damage caused by a lightning strike to a wireless system, Airspan recommends the following practices: Provide a direct grounding from the iR460, and the lightning or surge protectors to the same •...
0% to 95% non-condensing Size (L x W x H) 4 x 1 x 1" (102 x 25 x 25mm) Weight 3.1oz (88g) Ground Wire 14 AWG, 10" (26cm) long Connectors RJ45 Shielded Jacks UGD-D01035 Airspan Commercial and Internal Use...
2. Apply a layer of PVC tape to cover the self-amalgamating tape completely. Wrap the PVC tape tightly to avoid any creases or folds that might form traps for water. Figure 13: Applying the Self-Amalgamating Tape NEW DIAGRAM NEEDED Important: Make sure that the PoE connector is completely weatherproofed. UGD-D01035 Airspan Commercial and Internal Use...
1. Insert the RJ45 Male connector (shielded) into the iR460 Ethernet port. Ensure the connector is fully engaged before tightening the IP67 gland. Figure 23: Connecting the Earthing Cable Figure 24: Connecting the Ethernet Cable Figure 25: iR460 with Earth and Ethernet Cables Installed UGD-D01035 Airspan Commercial and Internal Use...
3.4 Mounting with AirHarmony 1000 Figure Figure 28, and Figure 29 show the schematic diagram of iRelay with AirHarmony 1000 on a small pole and large pole. Figure 27: iR460 with AirHarmony 1000 on a Small Pole—Front View UGD-D01035 Airspan Commercial and Internal Use...
Figure 28. iR460 with AirHarmony 1000 on a Small Pole—Side View Figure 29. iR460 with AirHarmony 1000 on a Large Pole 3.5 Mounting with AirHarmony 4000 Figure 30 shows the schematic diagram of iRelay with AirHarmony 4000. UGD-D01035 Airspan Commercial and Internal Use...
Equipment available at the installation site Main iR460 unit Mounting bracket PoE injector (with fixing kit) Ethernet cable assembly Required tools Large flat screwdriver for pole clamps Small flat screwdriver for DC PoE power terminations UGD-D01035 Airspan Commercial and Internal Use...
Page 34
460 Equipment Installation Guide wrenches for main unit mounting fixings Side cutters Wire strippers Ring terminals crimp tool Required ancillary equipment Laptop PC for initial configuration Ethernet cable for temporary connection of the laptop UGD-D01035 Airspan Commercial and Internal Use...
Page 35
Table 11. Network Configuration Information Parameter Description Parameter Value IP Address Netmask Default Gateway Address Management IP Mode. Management VLAN Management VLAN Tag Management IP Mode Ethernet Mode Ethernet Rate Ethernet Duplex UGD-D01035 Airspan Commercial and Internal Use...
Fit and secure the iR460 unit to the ☐ mounting bracket mounting bracket. ☐ Connect and manage cables Connect the protection earth. Connect the iR460 Ethernet cable. ☐ Connect the PSU. ☐ ☐ Connect power to PoE Connect power system ☐ UGD-D01035 Airspan Commercial and Internal Use...
Location of the power point Location for PoE PoE to power source distance PoE to iR460 distance Earthing/Grounding Earth connectivity is point Radio Surge ☐ Yes ☐ Yes ☐ Yes ☐ No ☐ No ☐ No UGD-D01035 Airspan Commercial and Internal Use...
Page 38
Length of the Cat5e cable required at site Length of the power cable required at site Length of the grounding cable Remarks Details of the Survey Engineer Name:______________________________________________ Mobile No:__________________________________________ Visit No:____________________________________________ Reason for the visit:__________________________________ Signature:____________________________ Date:________________________________ UGD-D01035 Airspan Commercial and Internal Use...
Earthing/Grounding ☐ Yes ☐ No Earth connectivity is available ☐ Yes ☐ No Earth of tower/pole verified ☐ Yes ☐ No Cable trays are earthed (if applicable) Tower/Pole Tower/pole height as per survey report UGD-D01035 Airspan Commercial and Internal Use...
Page 40
Length of the Cat5e cable required at site Length of the power cable required at site Length of the grounding cable Remarks Details of the Survey Engineer Name:______________________________________________ Mobile No:__________________________________________ Visit No:____________________________________________ Reason for the visit:__________________________________ Signature:____________________________ Date:________________________________ UGD-D01035 Airspan Commercial and Internal Use...
460 Equipment Installation Guide E Standard Torque Values – Metric System Use the following table (from http://electronicfilters.tpub.com/TM-10-4330-237-13P/css/TM-10-4330- 237-13P_105.htm) to determine the maximum safe torque for a particular size or grade fastener. Figure 31: Standard Torque Values UGD-D01035 Airspan Commercial and Internal Use...
Page 42
460 Equipment Installation Guide F Torque Setting for Serratub Maxi Steel Bands Figure 32: Serratub Maxi Steel Band Airspan uses Serratub Maxi Steel Bands (part number: MAXI 1 W2B 50-215) for mounting iR460 on a large pole. Figure 33 provides information on the recommended torque setting for these steel bands.
460 Installation related material Line-of-sight Miniature circuit breaker Personal computer Power over Ethernet Power supply unit PtMP Point to multipoint Point to point Ready for Installation Screw and washer assemblies Transmit Ultraviolet UGD-D01035 Airspan Commercial and Internal Use...