Floataway TRANQUILITY Installation Manual

Floataway TRANQUILITY Installation Manual

230v 50hz. 2017

Advertisement

Installation Manual
Tranquility 2017 [v3]
230v 50Hz
Revised March 2015
PLEASE READ THIS MANUAL TO THE END BEFORE STARTING
[ Updated : MAY 2017 ]
Floataway is a registered trademark of Cosine Limited.
8 Ironside Way, Hingham Business Park, Hingham, Norfolk, NR9 4LF, UK
Office +44 1953 851 515
Info@floataway.com
Factory +44 1953 851 861
www.floataway.com
Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3
1

Advertisement

Table of Contents
loading

Summary of Contents for Floataway TRANQUILITY

  • Page 1 Floataway is a registered trademark of Cosine Limited. 8 Ironside Way, Hingham Business Park, Hingham, Norfolk, NR9 4LF, UK Office +44 1953 851 515 Factory +44 1953 851 861 Info@floataway.com www.floataway.com Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 2: Table Of Contents

    Fitting the side panels • Identifying parts of the LAN cable • The remote control • Recommended values • The water and salt • Troubleshooting common problems • Remote Quick Guide Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 3: First Check The Room

    The remote control should not be easily accessible to the visiting public. Check how much hot water will be available and if a hose will be needed to fill the product. Plan where to put the salt and parts during the installation. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 4 There must also be a fuse or circuit breaker in the line. For 230v installations the fuse should be 20 Amp with suitable cables. • We recommend that the electrical installation of the supply be done by a suitably qualified electrician. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 5: The Silicone Heater Membrane Sheets

    Please read through this Manual before beginning the installation. If you are not confident of success, please hire an electrician to do the installation for you. Floataway will not be responsible for installation errors caused by not using these instructions.
  • Page 6 - these are the only parts that connect the isolated tub to the ground. The GNIS board can be seen here with the insulation, silicone heater mats and heaters ready for the tub to be placed down. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 7: The Skimmer And Pre-Filter

    Bring in the door carefully and place it onto the dome. The hinges are fitted to the door and will need to be guided into the mounting holes at the back of the tub.   Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 8 These have been factory installed. 10. Recheck the door opening and remove the towel. The photo on the right shows the installed hinge in its correct position.     Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 9: The Suction Assembly And Pump Connections

    Then connect the hose from the UV filter (optional) to the bottom of the filter housing as shown on the photo here : Each tube connection has two clips for reliability. Make sure all the pipe clips are tight.     Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 10: Water Isolation Check

    One has a longer cable to reach to the far side from the control box, which is on the suction side of the tub.   Make sure the jack brackets are tight. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 11: The Auto Doser - Liquid Disinfectant

    The hose should not dip into the water The back of the jet is fitted with an M14 nut, finger tight only, do not use tools, if overtightened it can sheer off the shaft of the jet. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 12 The filling cap is removed and then use the funnel to carefully fill the reservoir - do not overfill. fill when empty by adding 1Lt, do not fill to the brim. It will look like this when finished. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 13 If the bottle does not have a hole in the lid, simply drill one to have access for the pipe. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 14 11. Jack (door motor) connectors - 12v 12. LAN type communication socket with a RJ45 plug 13. Air switches for air buttons on tank 14. Main control board 15. Under water Light fuse - 2A Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 15: The Control Box Diagrams

    PUMP Pump MCB 1: 10A Heater 1&2 MCB 2: 10A Pump,PSU,UV Ground 50Hz Supply 230v AC 20A 230V 12v Power Supply (hot) Live Audio Amp Supply Neutral 230v 50Hz 20A Earth Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 16 Do not switch the tank on until there is water in the tub and do not switch on if the bottom of the tank (and therefore the heaters) is covered with Epsom salt which has not been fully dissolved. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 17: The Water Level Sensor

    10A fuse. Take care not to plug the battery into any other connector! End of Session Chime The Interface panel has an end of session chime that sounds when the float session has come to the end. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 18 Zone button 3 times within 10 sec. To UN-LINK a lamp to a zone : turn lamp OFF, and then ON, press corresponding Zone button 5 times within 10 sec. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 19: Xlr Connectors

    Use a qualified electrician to connect up the room light control. It can be used as part of a standard two-way switching circuit as seen above. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 20: Music Speaker

    Music Mute is built into the amplifier, there is an additional air button if fitted. The cable is fitted The sound to the side of the transducer is fitted tranquility in the to the side wall of factory the tank near the head area. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 21: Intercom System

    12v + : 12v+ via LAN - intercom box at tank : Brown GND : 0v via LAN - intercom box at tank : Orange : not used : not used : not used : not used Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 22: Music System

    Floataway does not provide the music source. Warning The Floataway system uses the headphone level output (one volt peak) which is always a 3.5mm stereo jack socket on typical equipment. No other music level (voltage) can be used, speaker output/high level will destroy the built in amplifier and risk damaging the control box itself.
  • Page 23 CAT5 Remote green amp wires between the connector and board 3.5mm audio tracks/jumpers on the board jack lead wires between the baords Sound source MP3 / PC? Float room Reception Area Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 24: The Remote Control

    Back (cancel) - if in settings, save y/n is asked on using this button Up / Down to navigate the menu items The Alarms are signaled by flashing red lights and an audible buzzer, the cancel button in the middle. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 25 At the start of the session, in the case of the Tranquility pod, the motorized door will open and wait for the customer, who will close the door when he or she is ready.
  • Page 26 , or to cancel and carry on with the float session. Ending the session is a sequence including the music fading up, lights and in the case of the Tranquility the door opening. Flashing Display If the electricity supply fails, the display will flash. The message will be “mains failure”.
  • Page 27 The buzzer can be cancelled by pressing the triangle centre button until it clears. A brief press will only stop the buzzer. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 28 Actually this is since the filter top was last opened, but usually that is to change a filter. The total session count is non-reset and is intended to keep a record for audit purposes. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 29: Recommended Values

    There is also a separate quick guide document on the operation of the remote There is also instructions for temperature calibration in the quick guide Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 30: The Water And Salt

    To run the pump with salt on the bottom can cause permanent damage to the pump. Floataway recommend the mixing of the salt to be done with the Float Pool turned off. Continue to run the pump to heat the water until it reaches approximately 35.5 degrees C which is the set point.
  • Page 31: Troubleshooting Common Problems

    When the salt is completely mixed, this effect disappears but can recur when more salt is added. If the tank is left in pump mode, the regular pumping will prevent this effect by mixing the salty layer. Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 32 Floataway is a registered trademark of Cosine Limited. 8 Ironside Way, Hingham Business Park, Hingham, Norfolk, NR9 4LF, UK Office +44 1953 851 515 Factory +44 1953 851 861 Info@floataway.com www.floataway.com Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 33: Program Modes

    FLOATAWAY - FLOAT CONTROL SYSTEM 2015 Floataway Control System The Floataway unique control system has been designed for you, it allows you to start automated sessions and to change parameters such as temperature, session length, music fade, and pump times.
  • Page 34 Adjust : Temperature Adjust : Music Adjust : St Session Time Temperature --.-C Music fade/on/o Change to : -- Change to : --.- Up/Down. Then OK Up/Down. Then OK Up/Down. Then OK Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 35 Change to : -- Change to : -- Up/Down. Then OK Up/Down. Then OK Start Pump Now <-- Stop Pump Now <-- Start Pump Now Stop Pump Now Save changes Save changes Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 36 Autodose refresh t4 Music Fadeout time fT Autodose on time t3 Change to : -- Change to : -- Change to : -- Up/Down. Then OK Up/Down. Then OK Up/Down. Then OK Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 37 Press OK to Save Or <-- to cancel Calibrate:Temperature Pump Refresh Time T5 RT Temperature : --.- Time : --.- Change to : --.- Change to : --.- Up/Down. Then OK Up/Down. Then OK Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3...
  • Page 38 This Icon is used for yes/no before returning to the last screen / level up in the menu Program times explained The Floataway control system allows you to adjust the times os many aspects of the pro- gram to optimise your product to best work with your centre. The controller is based around oat sessions and standby mode.

Table of Contents