Fishman LDS9000 Administrator's Manual page 14

Priming/dispensing only setup guide
Hide thumbs Also See for LDS9000:
Table of Contents

Advertisement

4.6
Prime Only – USB Configuration
4.7
On the screen the words "Prime Only" will
be visible above the illustration of a filled
syringe barrel. First, select the same syringe
barrel size used on the SmartDispenser
the automation system units. Any Dispense
Volume can be chosen as you will only be
utilizing the MANUAL(Auto) setting. Select
a Speed setting that is approximately 25%
of the fastest rate. Be certain that the
dispensing gun is fully retracted, the step
count at "0" and the footer buttons set to
EXTEND(Retract) and MANUAL(Auto).
Note:
"Prime Only" function is available exclusively in the
Traditional 9000 menu. "Dispense Only" function is
available in both Traditional 9000 and PC
14
Fishman Corporation
in
®
2
menus.