DISMANTLING INSTRUCTIONS
Dismantling of the Cassette Cover
2. Twist screw driver
1. Place screw driver
(flat side) between
3. Lift up and out
the cover & cassette
door
Opening the CDC Tray manually
1) Take a paper clip or any stiff wire diameter of 1mm -1.5mm
and make a marking about 17mm from the tip.
2) Place the set in an upright position and insert the paper clip
into the slot on the right side of the Cabinet Rear.
3) With the marking just outside the Cabinet Rear, you
should be able to engage the gear on the side of the
3CDC-LC Module. Because of the distance between the
gear and the Cabinet Rear the chance of the paper clip
slipping above or below the gear is high, therefore you
have to feel and adjust slightly to engage the gear cor-
rectly.
4) Push the gear slowly towards the front as shown until the
Tray CDC starts to move out of the Front Cabinet. The
Tray CDC is now disengage and can be pulled out com-
pletely
Note: If the Cabinet Rear has to be replaced, it has to
be replaced by one that has a similar slot on the
right side of the Cabinet otherwise there is no
possibility to disassemble the same set in the
future.
3-1
Cassette door
17mm
Marking just outside the
slot on the Cabinet Rear
Turn the Gear inside towards
the Front of the Set repeatedly
until the Tray CDC starts to
open.
Dismantling of the Front Panel
1) With the CDC tray opened remove the Cover Tray CDC
(pos 107) as indicated.
2) Loosen the 8 screws to separate the Front Panel from the
rear portion.
- 2 screws B on the front
- 2 screws each on the left & right side
- 2 screws at the bottom
3-1