Seko RINSTRUM R320 Technical Specifications

Seko RINSTRUM R320 Technical Specifications

Forklift scale accurate and affordable industrial truck scales digital scale indicator

Advertisement

Quick Links

Accurate and Affordable Industrial Truck Scales
RINSTRUM Model R320/323 - K356 - v4.16
General Features
User-friendly system available with built-in
troubleshooting diagnostics and our 24-7
technical support line. 307-321-4505
System is designed to work dependably and
accurately in the harshest environments,
Accumulation feature allows operators to either
count up for total or display single load weight.
Accurate and requires less than an hour to install
and calibrate
RS232 Printer accessory available providing
weight, date, time and total weight.
Two Setpoints with Isolated 300mA 50V Outputs
Internal Clock/Calendar
Options and Accessories:
Receipt Printer
Remote Switch for Accumulator Function
12Vdc Battery Line Conditioner
Voltage-Converter for 24Volt to 48Volt systems)
The SEKO Forklift Scale Modular Load Cell weighing system determines the load weight by
sensing the weight on the forks.
This signal is transmitted to the In-Cab Indicator, which displays the weight on the forks.
SEKO FORKLIFT SCALE
DIGITAL SCALE INDICATOR
Precision Static Weighing Lift Truck Scale.
Revised 25 June, 2017
System Technical Specifications
Technical Features
Input Power - Voltage: 9 - 18Vdc
Input Power - Current/Amps: Maximum: 500mA Input
Power - Current/Amps: Nominal: 150mA
Excitation Voltage: 5Vdc
Operating Temperature: 14F to 104F (10C to 40C)
Control Panel Key Functions:
Power/Units, ZERO, Tare, Select, Print, Function
Serial Port: Full Duplex RS-232 format
DisplayTechnology: 6 digit LCD 3/4" height
Housing Material: Grey ABS
Weight: 1 lb. 6oz.
Shipping Weight: 2 lb. 4oz.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the RINSTRUM R320 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seko RINSTRUM R320

  • Page 1 12Vdc Battery Line Conditioner Voltage-Converter for 24Volt to 48Volt systems) The SEKO Forklift Scale Modular Load Cell weighing system determines the load weight by sensing the weight on the forks. This signal is transmitted to the In-Cab Indicator, which displays the weight on the forks.
  • Page 2 Rinstrum R320 Scale Indicator Face View Side View Front View Rinstrum R320 Scale Indicator Rear View Rear View Side View with Boot...
  • Page 3: Electrical Installation

    Electrical Installation Rinstrum R320 Scale Indicator Power: 9Vdc to 18Vdc from Truck Electrical. Power may be attached via external plug or hardwired to internal Euro connector. Power Plug Connect power via Key Switch or directly to Battery Power. Polarity Recommended in-line fuse for truck electrical protection: 2.0A Minimum.
  • Page 4 Standard Rinstrum Rear Panel Wiring Options Alt: Brown Alt: Grey Yellow or Clear DTR Connection Optional Alt: Brown Normally Not Connected Alt: Grey Yellow or Clear R-320 Indicator Rear Panel Wiring with Remote Alarm Cable and Jumper Trim Wire End 3/8"...
  • Page 5 Operator Briefing Weighing Methods SEKO Modular Weighing System with Rinstrum Indicator Prepared by Technical Support 25 May, 2017 Simple weighing procedure which produces desired weight consistency and accuracy: Simply "Lift and Weigh": Load the forks and lift Allow the scale to calculate and display the weight of the load.
  • Page 6 SEKO Forklift Scale systems utilize Rinstrum's NTEP certified Scale Indicator producing display errors of less than +/- 0.03% and NTEP certified S-beam type load cells producing signals with +/- 0.03% error. The SEKO weigh module low-friction mechanical design allows better than +/- 0.1% displayed weight error in practice.
  • Page 7 Passcodes and Operator Lock-Out ( Normally NOT USED ) The instrument has two levels of passcodes to provide restrict Setup via the keypad. Full Setup Passcode (For calibration and Technician Access) Setting a passcode for Full Setup restricts any access to Full Setup. Full Setup passcode can also be used to access Safe Setup.
  • Page 8 POWER CHECK and Troubleshooting 1. POWER SOURCE Check to be sure the system has primary DC power applied. Power should be between 8Vdc and 18Vdc if powered from truck electrical or greater than 6Vdc using fresh "AA" batteries if utilizing internal battery pack. 2.
  • Page 9 This condition can produce an open circuit Voltmeter indication of satisfactory Voltage, because the resistance of degraded continuity is difficult to detect in an open circuit. Degraded circuit/wire/ ground connections can often be detected by detecting the difference in Voltage at the load when OFF and when ON.
  • Page 10: Default Set-Up Settings

    Default Set-Up Settings Rinstrum R320/323 Indicators K356 v4.16 Navigation: BUILD DP = 000000 (no decimals) Press ZERO Button to select major setting Group CAP = 5000 RES = 1 Press TARE Button to select Setting DUAL = 60000 UNITS = lb Press SELECT Button to acivate selected Setting HI.RES = OFF...
  • Page 11: Setup Menu

    Setup Menu SEKO Modular Weighing System Rinstum-R320/323 Indicators K356 v4.16 Firmware See also: "Short Calibration Procedure" Initial Setup Indicator Operating Parameters: Apply Power: Apply power to the indicator. Press the small Power Key (UNITS) on the left face of the Indicator to turn the Indicator ON. The Indicator should turn on automatically.
  • Page 12 Slightly above the maximum weight to be lifted in your application. Press SELECT to select digit and PRINT to change the value of the selected digit. The selected digit will flash. SEKO Forklift Scale may pre-set 005000 for most small forklift applications. "f/OK"...
  • Page 13 Note 1. The Indicated Weight will change by steps/increments of this amount. (i.e. 500, 510, 520, 530 etc. if rES = 10 ) Note 2. Default = "1" SEKO Forklift Scale normally sets to "1"display increments Note 3. Maximum increments is 3000. CAP divided by RES should always be 3000 or less.
  • Page 14 PRINT to select iNdUSt. f/OK to store the USE setting. Press The Display will show "USE" Press "T" (Tare) to select "FiLTEr" Set Filter None, .2, .5, 1.0, 2.0, 3.0, 4.0, 5.0, 7.5 Forklift Scale setting is 0.5 SEKO...
  • Page 15 Press SELECT The display will show 0.5 If other value, press PRINT until Display shows 0.5 f/OK to store the setting. Press Display will show FiLtEr (FILTER) Set Motion OFF, 0.5-1.0, 1.0 - 1.0 Press "T" (Tare) to select "MOt iON" (Motion) Press SELECT Display will show "0.5 - 1.0"...
  • Page 16 f/OK to store the OFF setting. Display will Press show Z.trAC Set Zero Range FULL, -2_2, -1_3, -20_20 Press "T" ( Tare ) to select "Z.rANGE" Display will show -2_2 If Press SELECT another value, press PRINT until Display shows -2_2 f/OK to store the setting.
  • Page 17 Calibrate Please complete Set-Up before proceeding to Calibration. Press " 0 " ( ZERO ) The Display will show " CAL " The CAL Mode will be discussed in the CALIBRATION PROCEDURE and is not discussed here. *********************************************************************** Please contact Tech Support for the following setting instructions: 307-321-4505 (24-7) Press "0"...
  • Page 18 Factory Reset - NOT ADVISED Press " 0 " ( ZERO ) The display will show " FACtrY " Exit Programming Mode Press "0" (ZERO) The display will show " END " Save Settings, Exit and Re-Start Weighing Mode Press " T " ( Tare ) To Save and Exit.
  • Page 20: Calibration Procedure

    Rinstum-R320/323 Indicators. Firmware K356 v4.16 (Last revision 25 May,2017) General comment: Your SEKO Weighing System can provide 99.9% or better accuracy and repeatability for most of your onboard weighing activities. CALIBRATION The Calibration process is performed in three steps: The first step establishes ZERO - the unloaded forks. We are actually weighing the empty forks to establish the ZERO (0) weight display.
  • Page 21 " 0 " ( ZERO ) " CAL " ( Press until is displayed ZErO "T" (Tare) Press (ZERO) to select " " SELECT "(some flashing number)" Press and the display will show "f/OK" ZErO Lift the empty forks to the weighing point and press to store the "...
  • Page 22 SPAN (two times) to select " " (SPAN) Press " " (Tare) key and the display will show "CLr.L N" Press SELECT Press PRINT to change N to y Press to store the "CLr.L N" setting. The Display will show a flashing "0 lb" Press The Display will show a flashing "XXXXXX lb"...
  • Page 23 Testing for Repeatability and Adjusting for Accuracy: It is good practice to lift your test weight several times to determine the repeatability of the machine, Scale Set Up and Driver Operation. If convenient, lift two or three other known weights of different ranges to assure yourself that the Weighing System weighs consistently and accurately across a range of weights.
  • Page 24 Testing for Repeatability and Adjusting for Accuracy: It is good practice to lift your test weight several times to determine the repeatability of the machine, Scale Set Up and Driver Operation. If convenient, lift two or three other known weights of different ranges to assure yourself that the Weighing System weighs consistently and accurately across a range of weights.

This manual is also suitable for:

Rinstrum r323Rinstrum k356