ETAS ES583.1 User Manual

Flexray bus interface usb module
Hide thumbs Also See for ES583.1:
Table of Contents

Advertisement

Quick Links

ES583.1
FlexRay Bus Interface USB Module
User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES583.1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ETAS ES583.1

  • Page 1 ES583.1 FlexRay Bus Interface USB Module User’s Guide...
  • Page 2 The data in this document may not be altered or amended without special noti- fication from ETAS GmbH. ETAS GmbH undertakes no further obligation in rela- tion to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license.
  • Page 3: Table Of Contents

    Properties ......... . . 15 ES583.1 - User's Guide...
  • Page 4 Problems with the ES583.1 ........
  • Page 5: General

    1.1.2 General safety information Please observe the Product Safety Notices ("ETAS Safety Notice") and the follow- ing safety notices to avoid health issues or damage to the device. Note Carefully read the documentation that belongs to the product prior to the startup.
  • Page 6: Intended Use

    1.1.4 Intended use This product was developed and approved for automotive applications. For use in other application areas, please contact your ETAS contact partner. Requirements for operation The following requirements are necessary for safe operation of the module: • Observe the notes for the ambient conditions (see chapter 5.1.2 on page 25).
  • Page 7: Rohs Conformity

    The user is obligated to separately collect old devices and provide them to the WEEE return system for recycling. The WEEE Directive applies to all ETAS devices, but not to external cables or bat- teries. Additional information about the recycling program of ETAS GmbH is available from the ETAS sales and service locations (see chapter 8 on page 37).
  • Page 8: Identifications On The Product

    Operating voltage range (DC voltage) Marking for CE conformity, see chapter 1.3 on page 7 Marking for RoHS, see chapter 1.2.1 on page 7 Please observe the information in the chapter "Technical Data" on page 25. ES583.1 - User's Guide...
  • Page 9: About This Manual

    Bold Labels of the device Italic Particularly important text passages Important notes for the user are presented as follows: Note Important note for the user. ES583.1 - User's Guide...
  • Page 10: Structure

    • Chapter 4: "Troubleshooting Problems" This chapter gives some information of what you can do when problems arise with the ES583.1 and when general problems arise that are not spe- cific to an individual software or hardware product. • Chapter 5: "Technical Data"...
  • Page 11: Hardware Description

    The ES58x series consists of a series of compact ECU and bus interface module to cost-efficiently connect vehicle buses with the PC. The compact ES583.1 module is equipped with a FlexRay interface at a DSUB9 plug connector and with a USB port for connection to the PC. The Y-shaped cable CBCF100 connects the SUB-D plug connector of the module with the FlexRay channels.
  • Page 12 – Immune to ambient conditions (temperature, EMC) – High level of mechanical stability and robustness • Part of the ETAS Tool Suite Complete technical data for the ES583.1 module can be found in the chapter "Technical Data" on page 25. ES583.1 - User's Guide...
  • Page 13: Housing

    The serial number of the module is located at the bottom of the device. LEDs The ES583.1 is equipped with an LED to display the operating state of the mod- ule and with two LEDs to display the function of both FlexRay channels FLX1 and FLX2.
  • Page 14: Function State Of Flexray Interface

    Flashing yellow Flashing yellow FlexRay node active (channel A and channel (code 1) (code 1) B), waiting for synchronization Yellow Yellow FlexRay node active (channel A and channel B), synchronized, ready for data exchange ES583.1 - User's Guide...
  • Page 15: Block Diagram

    Block diagram USB port The ES583.1 must be connected to a USB 2.0 high-speed port (480 Mbit/s). Since the module is supplied with power via the USB port, it must provide an output current of 500 mA (USB 2.0 high power).
  • Page 16: Synchronization Nodes

    • Flashing ECUs via FlexRay Firmware update The firmware of the ES583.1 can be updated by the user so that future versions of the module can also be used. The firmware update is done with the help of the service software "Hardware Service Pack" (HSP) from the connected PC.
  • Page 17: Startup

    ES583.1. Preparing the installation 3.1.1 USB driver Note A specific USB driver must be installed on the PC for operating the ES583.1 module. 3.1.2 Checking system requirements Verify that your PC meets the system requirements. To install the USB driver on the PC, you require the user rights of an administra- tor.
  • Page 18 Startup ETAS • Click on Next and follow the instructions of the installation program. • Accept the general terms of the software licensing agreement. • Click the Continue button. The installation of the USB driver starts. ES583.1 - User's Guide...
  • Page 19 ETAS Startup • Wait until the driver is installed. • Click on Finish. The installation of the USB driver is finished. ES583.1 - User's Guide...
  • Page 20: Uninstalling The Usb Driver

    Startup ETAS Uninstalling the USB driver The USB driver for the ES583.1 can be uninstalled in the Device Manager of Windows. Uninstalling the USB driver: • Select Start → Control Panel → Device Manager to start the Windows Device Manager.
  • Page 21: Verifying The Installation Of The Usb Driver

    Fig. 3-1 Windows Device Manager When Windows detects the ES583.1 module at the USB port, but the USB driver for the module was not installed, then an exclamation mark ( ) appears next to the entry for the module.
  • Page 22: Connection To The Pc

    ETAS Connection to the PC After successful driver installation, the ES583.1 module can be connected to the PC. Windows should recognize the module and install (enable) the correspond- ing driver. Windows displays an information note in the start bar (see Fig. 3-2 on page 22).
  • Page 23: Troubleshooting Problems

    Troubleshooting Problems Troubleshooting Problems This chapter gives some information of what you can do when problems arise with the ES583.1 and when general problems arise that are not specific to an individual software or hardware product. Displays of the LEDs For assessing the operating states and for removing errors of the ES583.1,...
  • Page 24 Troubleshooting Problems ETAS Problem Diagnostics questions Possible solutions The ES583.1 module is Did you install INCA with Check whether the INCA not found using the required version? version installed on your "Search for hardware". PC meets the require- ments in chapter 5.2.2 on page 28.
  • Page 25: Technical Data

    5.1.3 Maintenance of the product Do not open or change the module housing! Work on the module may only be performed by qualified personnel. Return defective modules to ETAS for repair. 5.1.4 Cleaning the product We recommend cleaning the product with a dry cloth.
  • Page 26: Mechanical Data

    Technical Data ETAS 5.1.5 Mechanical data 39,97 19,90 Fig. 5-1 Dimensions Length (housing with cable) approx. 1.5 m Weight 120 g (without cable) ES583.1 - User's Guide...
  • Page 27: System Requirements

    Configuration Plug & Play The ES583.1 module may be operated only directly on the PC or on an active hub whose USB port meets the requirements listed in the table. The module must be directly connected to the USB port of your PC. The use of USB-cables extending the connection between the ES583.1 and the PC is not...
  • Page 28: Software

    Technical Data ETAS 5.2.2 Software Supported applications and software prerequisites For the configuration of the ES583.1 as well as the control and data acquisition, you need software in the following versions (or higher): Inter- Application / Classifi- Support in the...
  • Page 29: Electrical Data

    254 bytes Hardware-based filtering Slot counter, Cycle counter and chan- Physical layer Transceiver Philips TJA 1080A Termination 100 ohm Transmission speed, max. 10 Mbaud / channel Other Boot time < 1 s Timestamp 1 μs 64 bit ES583.1 - User's Guide...
  • Page 30: Terminal Assignment

    FlexRay 2 (channel B), bus minus Ground Not connected FLX1 B-plus FlexRay 1 (channel A), bus plus FLX2 B-plus FlexRay 2 (channel B), bus plus Not connected A 9-pin DSUB plug is connected to the "FLX1/ FLX2" socket. ES583.1 - User's Guide...
  • Page 31: Cables And Accessories

    Mapping of DSUB plug connectors "1" and "2" to the ES583.1 If a CBF100 cable is used at the FLX1/FLX2 interface of the ES583.1, these inter- faces are mapped as follows to the DSUB plug connectors "1" and "2" of the cable: ES583.1...
  • Page 32 Cables and Accessories ETAS ES583.1 - User's Guide...
  • Page 33 ETAS Cables and Accessories Pin assignments of the cable at the FLX1/FLX2 interface The signals of the FLX1/FLX2 interface of the ES583.1 are assigned as follows to the DSUB plug connectors "1" and "2" of the CBCF100 cable: DSUB socket DSUB plug connector "1"...
  • Page 34: Flexray Termination Resistor

    Cables and Accessories ETAS FlexRay termination resistor 100R0 / 1% Fig. 6-3 Termination resistor CBFX131-0 Order name Short name Order number FlexRay termination resistor 100 ohm, CBFX131-0 F 00K 104 689 2xDSUB (9fc-9mc), 0 m ES583.1 - User's Guide...
  • Page 35: Order Information

    Order Information Order Information ES583.1 Order name Short name Order number ES583.1 FlexRay Bus Interface USB Module ES583.1 F 00K 107 805 Package Contents ES583.1 FlexRay Bus Interface USB Module (2 channels), including CD-ROM ES583.1_CD (CD with drivers and manuals for ES583.1)
  • Page 36 Order Information ETAS ES583.1 - User's Guide...
  • Page 37: Etas Contact Addresses

    Germany WWW: www.etas.com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php...
  • Page 38 ETAS Contact Addresses ETAS ES583.1 - User's Guide...
  • Page 39: Figures

    ETAS Figures Figures Fig. 1-1 WEEE symbol....................7 Fig. 2-1 ES583.1 module (top view) ................. 11 Fig. 2-2 LED flashing codes..................13 Fig. 2-3 Block diagram..................... 15 Fig. 3-1 Windows Device Manager ................21 Fig. 3-2 Windows information note ................. 22 Fig.
  • Page 40 Figures ETAS ES583.1 - User's Guide...
  • Page 41: Index

    Operating state 13 Electrical safety 6 Operation Error state 13 Conventions 9 ETAS Contact Addresses 37 Use Case 9 Order Information 35 Overtemperature 13 Firmware update 16 Flashing 16 Flashing codes 13 Plug & Play 17 ES583.1 - User's Guide...
  • Page 42 Synchronization node, internal 16 Synchronization nodes 16 Synchronization process 16 System requirements 27 USB port 15 Use, intended 6 User rights 27 Voltage supply 29 Waste Electrical and Electronic Equip- ment - WEEE 7 WEEE return system 7 ES583.1 - User's Guide...

Table of Contents