INSTALLATION OF THE OPTIONAL
HOT WATER LOOP KIT FOR PRE-
HEATING OF DOMESTIC WATER
(PA08550)
MAX CADDY FURNACE
45392A
05-06-2015

Advertisement

loading

Summary of Contents for PSG PA08550

  • Page 1 INSTALLATION OF THE OPTIONAL HOT WATER LOOP KIT FOR PRE- HEATING OF DOMESTIC WATER (PA08550) MAX CADDY FURNACE 45392A 05-06-2015...
  • Page 2 This option can be installed on either side of your Max Caddy furnace. It is important to note that this option requires a 60 gallons buffer tank. For installation on the right hand side, follow steps 1 to 5 of section 1. For installation on the left hand side, follow steps 1 to5 of section 2.
  • Page 3 Step 2: Remove the right panel as shown in figure 3 and save the screws for step 5. Right panel Screws (12x) Figure 3 Step 3: Slide the hot water loop assembly into furnace, between the firebox and the heat exchangers.
  • Page 4 Cut view showing position of the hot water loop above the fire box. (Figure 5) Short bracket Figure 5 Step 4: Remove the knock-outs from the right side panel and install the grommets in the holes as shown on figure 6. Grommets (2x) Figure 6...
  • Page 5 Step 5: Insert then slide the inlet and outlet tubes of the assembly through the grommets and secure the panel to the furnace using the screws removed in step 2. (Figure 7) Right panel Screws (12x) Figure 7 Identify the water inlet (lowest tube) and outlet (highest tube) for installation purposes.
  • Page 6 Section 2 INSTALLATION OF THE HOT WATER LOOP KIT FOR PRE-HEATING OF DOMESTIC WATER ON THE LEFT HAND SIDE Step 1: Remove the screw located on the left of the assembly as shown on figure 9. Keep this screw to install the “Long”...
  • Page 7 Step 2: Remove the left panel as shown in figure 11 and save the screws for step 5. Screws (12x) Left panel Figure 11 Step 3: Slide the hot water loop assembly into furnace, between the firebox and the heat exchangers.
  • Page 8 Cut view of the inside of the Long bracket furnace with the hot water loop kit centered above the firebox. (Figure 13) Figure 13 Step 4: Remove the knock-outs from the left side panel and install the grommets in the holes as shown in figure 14.
  • Page 9 Step 5: Insert then slide the inlet and outlet tubes of the assembly through the grommets and secure the panel to the furnace using the screws removed in step 2. (Figure 15) Left panel Screws (12x) Figure 15 Identify the water inlet (lowest tube) and outlet (highest tube) for installation purposes.
  • Page 10 WARNING TO AVOID RISK OF DAMAGE IN CASE OF WATER OVERHEATING, YOU MUST USE COPPER PIPES TO MAKE THE CONNECTIONS BETWEEN THE TEMPERING TANK AND THE HOT WATER LOOP KIT FOR PRE-HEATING OF DOMESTIC WATER, FOR BOTH THE INPUT AND OUTPUT OF THE WATER LOOP ASSEMBLY.
  • Page 11: Wiring Diagram

    WIRING DIAGRAM WE RECOMMEND TO INSTALL A 24 VAC, MAXIMUM 200Ma, NORMALLY OPENED SOLENOID VALVE ON THE INLET OF THE HOT WATER LOOP KIT TO PREVENT COLD WATER FROM CIRCULATING IN THE FURNACE WHEN NOT IN USE. CONNECT THE VALVE TO THE ‘’WATR SOLN’’...