THANKS TO CHOOSE A TELEDIF ITALIA PRODUCT To obtain the maximum performance and to use the features and functions of the micro TSA 4.0 in the best way, read this manual carefully and keep it handy for any consultation. Micro TSA 4.0 system is specifically designed to help, someone eventually locked in a cabin lift, to raise an alarm to a service center.
Page 3
Feed the power supply to MICRO TSA 4.0, 12Vcc/500mA (CN1 1-2), matching the polarity. Configure the MICRO TSA 4.0 from a local touch tone phone, program at least one emergency num- ber (parameter "81" on page 15, or parameter 99 on page21) Hang up the phone and wait for the red light stops flashing.
Page 4
Link map Green led (power) Red led (line busy and test) + Pwr Local Phone A - Pwr Local Phone B + 485 Alarm sent - 485 Alarm received 12 Vcc not regulated not stabilized Technical Alarm Main Alarm Phone Line A 10 Phone Line B...
Page 5
Installation kit sample Sample of a tipical complete installation of micro TSA 4.0 with power supply ups T.ALI, and connected to a gateway Echo GSM4...
END OF ALARM (MAIN AND TECHNICAL) ROUTINE CALL (TEST CALL) The micro TSA 4.0 system always runs the first 2 events with higher priority (Event 1 has higher priority than 2, etc.). If a higher priority came during an event, the micro TSA 4.0 suspend the procedure in progress to handle the new event and after handling the event will resume the event suspended.
Page 7
A call to the number programmed in CLI mode (see Section C.3.9 gives) C.2.1.7) End of alarm The MICRO TSA 4.0 system , after a main alarm, can handle a End of alarm procedure or Notification of Alarm acceptance in three different ways From remote: After an alarm call, call the phone number of the micro TSA 4.0, which generated...
Page 8
NOTE: If the MICRO TSA 4.0 is connected to a gateway GSM instead of an analog phone line or internal control unit, it is possible to have difficulty recognizing dtmf tones, especially in the presen-...
Enter any DTMF digit to re-charge the time out. While connected, you can access to "remote controls" (Section C.2.2) using the relevant “control codes”. Communication is closed and the MICRO TSA 4.0 returns to rest in the following cases: typing and recognition of the digit "9" ...
Page 10
READ code Read the value of the parameter How to program: From a remote telephone enter to the system (call the MICRO TSA 4.0, and after liste- ning to the location message, press digit asterisk (*); Wait for the prompt “enter the password”...
05 - 90 Ring duration setting 10 = 100 msec. 0 = No Playback dial tone in 0 / 1 cabin during alarm 1 = Si *: You should change the parameter marked only by indications of the Teledif Techincian.
C.3.2) MAIN ALARM - END OF ALARM MAIN ALARM Your Value Function Notes Parameter fault Value 1° telephone number (*) Voice or Ademco call 2° telephone number (*) Voice or Ademco call Max 20 3° telephone number (*) Voice call digits 4°...
Page 13
If you are not satisfied with the result, repeat the procedure from step 4. NOTE: In case of noisy or bad quality recording, power the MICRO TSA 4.0 from a battery or a good efficient power supply and use a good quality.
Page 14
C.3.4) TEST CALL Routine call (test) PARA- VALORE FUNZIONE NOTE METRO fault Valori Max 20 Telephone number digits 0 - 9 N° loops 0 = Infinite 01 - 99 Time between 2 calls In days Waiting time for the next call 00 - 23 In Hours (HH + MM)
Page 15
C.3.7) OPEN COLLECTOR OUTPUT RELAYS PARA- VALUE FUNCTION NOTES METER fault Values 0-5 used for “Telecontrol” 0 = GND output while DTMF presence 1 - 4 = GND output from 1 to 4 seconds 5 = Connected to GND in latched mode: each pression of digit 1 change the state of the output 6 - 9 used for “Alarm sent”:...
Page 16
C.3.7.1) "Alarm sent” and “Alarm received”" The two reports ouput of the MICRO TSA 4.0 system, properly programmed, can better manage light signals and / or Sound for Alarm Received and Sent. Alarm Sent When you start a main alarm procedure, the ouput 1, if programmed, activates the signal "alarm sent"...
Page 17
C.3.10) COMMUNICATION CODES The system MICRO TSA 4.0 communicate with a call center via DTMF or “Ademco Contact ID” protocol. To select the protocol program the parameter 11 (see Section C.3.1).
Page 18
C.4) ERRORS In the error condition, indicated by the quick flashing of the red LED on board and the output 1, if you enter into communication with MICRO TSA 4.0 from a remote phone, you can hear the error message.
During the warranty period the equipment will be replaced or repaired free in the laboratories of Teledif Italia in Turin. The cost of transport to and from the laboratory Teledif Italia is always charged to the customer. The equipment to be repaired under warranty must be submitted toTeledif Italia in its original packaging and always accompanied by a copy of the purchase.
Page 20
TELEDIF ITALIA S.R.L. Via Reiss Romoli 194 - 10148 TORINO - Italy Tel.: 011.70.70.707 Fax: 011.19.82.49.13 Web: www.teledif.it E-mail: teledif@teledif.it Certified UNI EN ISO 9001:2008 Reg. n° ER/ES-1072/2002...