ENGLISH
5. BOILER TEMPERATURE PROGRAMMING
The boiler installed in the machine is set to a temperature of 120 °C which corresponds to a pressure
in the boiler of 1 Bar.
You can change the temperature (and the pressure) of the boiler as follows :
•
turn on the machine by pressing the PROG/STOP key for at least 5 seconds;
•
the set temperature value can be seen by observing the flashing modes of the push button
panel:
Hundreds
Ones
•
to increase the temperature of the boiler, press the key
the key
•
to confirm and exit programming, turn the machine off and then back on.
ATTENTION
It is advisable to set a boiler temperature inclusive between the following values:
minimum: 116°C (0,8 Bar) - maximum 122°C (1,2 Bar).
ATTENTION
You can modify programming of the boiler temperature for the CKX version as well by
requesting assistance from qualified service personnel.
70
Tens
(each press of a key modifies the temperature by 1°C);
use and maintenance manual
(only for CKXE version)
Example :
• one flash of key LED
• two flashes of key LED
• one flash of key LED
Set temperature 121°C
To reduce the temperature press
100°C
20°C
1°C