Auto-ranging voltage indicator 600v - 69kv; 69kv - 500kv

Advertisement

Quick Links

Operating Instructions
Auto-Ranging Voltage Indicator
Catalog No.
C403-3374
Voltage
600V - 69kV
The equipment covered in this manual must be used and serviced only by competent,
trained personnel familiar with and following approved work and safety practices.
This equipment is for use by such personnel and this manual is not intended as a
substitute for adequate training and experience in safe procedures for this type of
equipment.
These instructions neither cover all details or situations in equipment use, nor do
they provide for every possible contingency to be encountered in relation to
installation, operation or maintenance. Should additional information and details be
desired or if situations arise which are not covered adequately for the user's purpose,
the specifics should be referred to Hubbell Power Systems, Chance
Before operating a CHANCE
understand, and follow these instructions. Keep these instructions in the device
case for future reference.
Do not allow universal fitting to touch any part of URD cabinet, to become grounded
in any other way, or to contact another phase as this will cause erroneous voltage
indication and could cause severe personal injury or damage to equipment.
©
Copyright 2005 Hubbell Power Systems
for
CAUTION
!
NOTICE
®
Auto-Ranging Voltage Indicator, thoroughly read,
!
WARNING
®
Sold by:
Catalog No.
C403-3375
Voltage
69kV - 500kV
®
.
P403-3408
http://www.TWAcomm.com
Toll Free: (877) 389-0000
rev A

Advertisement

loading

Summary of Contents for CHANCE C403-3374

  • Page 1 Should additional information and details be desired or if situations arise which are not covered adequately for the user’s purpose, ® the specifics should be referred to Hubbell Power Systems, Chance NOTICE ® Before operating a CHANCE Auto-Ranging Voltage Indicator, thoroughly read, understand, and follow these instructions.
  • Page 2 Readings from the ARVI represent the class of voltage that is present on the line. The C403-3374 is designed to determine phase-to-phase voltage classes up to 69kV. The C403-3375 is designed to determine phase-to-phase voltage classes up to 500kV.
  • Page 3 Ranges The approximate voltage ranges to provide indication of each of the voltage classes are as follows: C403-3374 ARVI ONLY C403-3375 ARVI ONLY Voltage Class Voltage Range Voltage Class Voltage Range 600V 480V to 900V 69kV 50kV to 109kV 1kV to 6.5kV...
  • Page 4 Verify full unit function by contacting with a known energized high voltage source or with the appropriate Voltage Indicator Tester (C403- 3409 for C403-3374 ARVI and C403-3431 Voltage Indicator Tester for C403- 3375 ARVI). 2. Thread the hook probe into the end fitting of the ARVI and attach universal fitting to an insulated hot stick of proper length for system voltage involved.
  • Page 5 If ever in doubt about interpreting ARVI reading under any circumstance, always assume circuit is energized and take appropriate safety precautions. Operation — Underground (URD) C403-3374 ONLY WARNING Do not allow universal fitting to touch any part of URD cabinet, to become grounded in any other way, or to contact another phase as this will cause erroneous voltage indication and could cause severe personal injury or damage to equipment.
  • Page 6 1. Due to the close proximity of energized parts and grounded surfaces, probes must not be used when using the ARVI on live-front URD equipment because probes could either bridge from phase-to-phase or phase-to-ground or suffi- ciently reduce clearance to cause flashover. Therefore the probes must be removed from the tool.
  • Page 7: Battery Replacement

    Optional Method for Elbow/Cable Test Elbow-puller tool Elbow Adapter T403-0856 T403-0857 Up to 35kV Elbow Adapter Up to 35kV Bushing Adapter T403-0428 15kV Bushing Adapter Interpretation of ARVI readings on Underground (URD) Reading Circuit Condition Appropriate line-to-line voltage class Energized No Indication De-Energized If ever in doubt about interpreting ARVI reading under any circumstance,...
  • Page 8: Specifications

    Auto-Ranging Voltage Indicator, 600V – 69kV includes C403-3374 Instruction manual Plastic Case Auto-Ranging Voltage Indicator, 69kV – 500kV includes Instruction manual C403-3375 Plastic Case Voltage Indicator Tester for C403-3374 ARVI C403-3409 Voltage Indicator Tester for C403-3375 ARVI C403-3431 15-35kV Elbow Adapter T403-0856 15-35kV Bushing Adapter T403-0857 6’...

This manual is also suitable for:

C403-3375