APPLICATION: This pump is fit for purpose when installed correctly according to these instructions;
For pumping of Clean Fresh Water at a temperature of +5°C to +40°C to: Garden Taps, Garden Sheds or similar, Clean Water Transfer, and
for no other use. It is not intended for use for whole-of-house supply or commercial applications. It must not be used in hazardous
locations, or for liquids other than clean water, or in continuous running applications, or in applications that require frequent starting and
stopping.
IMPORTANT: Ensure the pump is the right size for your application, before you install it. A pump that is under-sized is not faulty, and is not
covered by warranty. Ensure the right size piping is used, small pipes will reduce performance and will cause the pump to use much more
power, costing you a lot of money in the long term! See 8 in the instructions below for further information
MODEL
POWER
AMPS
WATTS
DT42
2.5
370
NOTES: Performance data quoted is generally from test data, and can vary, and does not take into account factors in the installation such as loss of pressure and flow due to pipework
& pipe-fittings & valves. Product depicted may differ from the product supplied, due to design changes or improvements. *Amps and Wattage vary according to the load on the motor.
INSTALLATION GUIDELINES
Please read and follow the instructions. Warranty is voided if the instructions are not followed.
1. IMPORTANT MANDATORY REQUIREMENTS FOR ALL INSTALLATIONS: Before installing or servicing disconnect from the power supply. All
pumps must be installed using barrel-union connections to facilitate easy servicing or replacement. Ball-valves or gate-valves must be fitted on
the suction, and the discharge, and the Town-water backup supply where fitted. A Y-Strainer or Pre-filter must be installed on the suction to
prevent particles entering the pump. Remove all swarf from the tank after cutting openings etc – swarf in the pump voids warranty. All
instructions are conditions of warranty; all warranty is void if instructions are not followed.
It is recommended to install a Check-Valve in the discharge pipework, however DO NOT install the check valve directly on the discharge of the
Pressure Controller, as this may cause it to malfunction, install the Check-Valve further down the pipe, before the first point of discharge.
2.POSITION Do not position the pump where it could take in solids or sludge. This pump is not to be used as your sole water supply. For critical
applications where loss of water supply could cause serious consequences, use a DUAL PUMP System so you have a backup water supply or
use a TOWN-WATER BACK-UP SYSTEM. This pump is not designed nor intended to be used for Fire Fighting purposes.
3.PROTECT FROM THE WEATHER: The pump must be protected from the weather, by way of a plastic pump cover or skillion roof cover, or
similar. However the installer must ensure that there is adequate ventilation so the pump does not overheat.
Page | 1
Ascento Group Australia 37 Export St, Lytton, Brisbane, QLD 4178 P: 1800807604
OUTLET
RATED
MM
INCH
FLOW
HEAD
(lpm)
(m)
25
1
23
18
MAXIMUM
WATER
OUTLET
FLOW
HEAD
NUMBER
(lpm)
(m)
OF TAPS
37
37
2-3
SIZE
LxWxH (mm)
2
260x180x340

Advertisement

loading

Summary of Contents for Waterpro DT42

  • Page 1 INSTRUCTION MANUAL & WARRANTY – WaterPro DT42 PUMP APPLICATION: This pump is fit for purpose when installed correctly according to these instructions; For pumping of Clean Fresh Water at a temperature of +5°C to +40°C to: Garden Taps, Garden Sheds or similar, Clean Water Transfer, and for no other use.
  • Page 2 Warranty. 11. MAINS PRESSURE BOOSTING The DT42 Pump is not recommended for this type of application. It is a specialized type of application, and must be completed by a Qualified Plumber or Pump Technician who is competent and licenced to perform this type of installation.
  • Page 3 16. SUCTION LIFT The DT42 Pump is not the best type of pump for Suction lift. Suction lift is pumping out of a tank that is at a lower level or underground. You should use a JET style of pump for suction lift applications. If however you decide to do so, follow the instructions below, but be aware that Ascento is not obligated to provide technical support or field service if you have installed this DT42 pump in a suction lift application.
  • Page 4: Problems & Possible Causes

    TROUBLESHOOTING CHECKLIST (CAUTION: SHUT OFF POWER TO PUMP) Check the following before requesting service or repair. PROBLEMS & POSSIBLE CAUSES 20. Light Flashes “No Water” or “Failure” * This normally indicates that the pump has no water, either because the tank is empty or the pump has “lost prime” – run dry. This is normal if the tank is empty, or the pipe has an airlock in it, or the suction pipe has a leak in it and it has let air into the suction pipe.
  • Page 5: Electrical Precautions

    WARNING!!! ELECTRICAL PRECAUTIONS Before servicing a pump, always shut off the power supply and then make sure you are not standing in water and that there is no risk of electrical shock. If pump is direct-wired to the electrical circuit, have a qualified licensed electrician disconnect it before attempting any repairs or servicing.
  • Page 6: Privacy Statement

    2. This warranty against defects covers failure due to manufacturing defects within a 12 Month period from the date of original purchase, for WaterPro™ Pumps purchased and used in mainland Australia. In the case of a failure covered by warranty within 12 months period from the date of original purchase, the pump will be repaired or replaced - or you can return it to the place of purchase for a refund.