MULTI-DECK MERCHANDISER INSTALLATION & OPERATIONS MANUAL MEAT/CHEESE Table of Contents Energy Data & Case Dimensions .......2-4 Pre-Power Checklist ..........12 General Information ..........5 Airfl ow & Defrost ..........13 Installation ............6-7 Case Cleaning ..........14-15 Case Connections ..........8-9 Parts Ordering ............16 Lighting and Power Supplies ......
Page 3
LIABILITY NOTICE For Cases with Shelf Lighting Systems Hillphoenix does NOT design any of its shelf lighting systems or any of its display cases with shelf lighting systems for direct or indirect exposure to water or other liquids. The use of a misting system or water hose on a display case with a shelf lighting system, resulting in the direct or indirect exposure of the lighting system to water, can lead to a number of serious issues (including, without limitation, electrical failures, fi...
Page 4
Important ® t Hillphoenix , the safety of our customers and employees, as well as the ongo- ing performance of our products, are top priorities. To that end, we include impor- tant warning messages in all Hillphoenix installation and operations handbooks, accompanied by an alert symbol paired with the word "DANGER", "WARNING", or "CAUTION".
Page 5
Revision History • new manual format_08/12 • parts list_09/12 • energy data and parts list_01/13 • endviews_03/13 • text update and airfl ow diagram_06/13 • energy data_07/13 • energy data_02/14 • endviews and energy data_09/14 • support diagram and parts page_02/15 •...
ENERGY DATA AGB REMOTE GRAVITY Electrical Data High Effi ciency Anti-Condensate Drain Optional Defrost Fans Fans Heaters Heaters Humidifi cation Fans 120 Volts 120 Volts 120 Volts 208 Volts 120 Volts Model Case Amps Watts Amps Watts Amps Watts Amps...
Page 7
ENERGY DATA AGB REMOTE GRAVITY Defrost Controls Electric Defrost Timed-Off Defrost Hot Gas Defrost 9,10 Defrosts Run-Off Fail-Safe Termination Fail-Safe Termination Fail-Safe Termination Model per Day Time (min) (min) Temp ( (min) Temp ( (min) Temp ( Gravity Coil - - -...
Page 8
CASE DIMENSIONS AGB REMOTE GRAVITY 30 in 36 in REFLECTIVE T8 VERTICAL REFLECTIVE T8 VERTICAL [76.2 cm] [91.4 cm] REAR LOAD DOORS REAR LOAD DOORS LIGHTING LIGHTING 11 11/16 in 11 11/16 in [29.7 cm] [29.7 cm] 19 7/8 in 25 7/8 in [50.5 cm]...
14 days of receipt of the equipment. This manual specifically covers the AGB-RG aged meat and Failure to follow this procedure will result in refusal by the cheese application, service multi-deck merchandiser.
CASE INSTALLATION LOCATION SUPPORTS This refrigerated display case has been designed for displaying and storing perishable food product. It is engineered for air- conditioned stores with a maximum ambient of 75°F and 55% relative humidity. When selecting the location for placement of this case, avoid the following conditions: Excessive Air Movement Fig.
CASE INSTALLATION track and snap into place. 6. After suffi cient time has passed to allow for bumper shrinkage, cut away the excess bumper for fi nal fi t and fi n- ish. Be certain to use an appropriate cutting tool (tubing- or PVC-cutter) to ensure a smooth cut.
CASE CONNECTIONS REFRIGERATION Refrigeration connections will be made through the refrigera- tion stub up location on the customer left side of the case. Refrigeration lines may be headed together for all cases in a line-up, if necessary, by lines through the access holes with a high grade silicon to prevent recirculation.
CASE CONNECTIONS MECHANICAL ACCESS LOCATIONS 15" x 15" MECHANICAL ACCESS 18 in FOR ELECT. ,REFRIG. ,AND DRAIN CONNECTIONS TOEKICK [45.7 cm] 14 in [35.6 cm] 30 in [76.2 cm] 26 in [66.0 cm] (30") 36 in [91.4 cm] 32 in [81.3 cm] (36") 28 in [71.1 cm] (30") 34 in [86.4 cm] (36") TOEKICK...
LIGHTING & POWER SUPPLIES GENERAL LIGHTING INFORMATION Hillphoenix cases are equipped with either T-8 lights or LED luminaires and feature specially designed light reflectors in the cornice to improve the illumination of products. Depending on case configuration, T-8 electronic ballasts or LED power sup- plies operate both the cornice and shelf lights and are located above the cornice reflectors.
LIGHTING & POWER SUPPLIES REPLACING LED LIGHTS Once store power is connected and the light circuit is ener- gized, the Clearvoyant LED system should operate without the need for any signifi cant maintenance for several years. Should a power supply need to be removed and/or replaced, turn off the power to the case before proceeding.
PRE-POWER CHECKLIST Before powering-up the case, be certain that all of the steps listed below have been completed to ensure proper case functionality, safety and compliance with warranty terms. Have you thoroughly examined the case for shipping damage? (see pg. 5) Have you checked the vertical plumb of the case? The horizontal level? (see pg.
AIRFLOW & DEFROST HUMIDIFICATION SYSTEMS AIRFLOW & PRODUCT LOAD The starting point for proper humidity levels in the AGB display Hillphoenix cases provide maximum product capacity within the case are typically around 75% RH when stocked with product. refrigerated air envelope. Please keep products within the ap- propriate load limit.
CASE CLEANING CASE CLEANING A periodic cleaning schedule should be established to maintain proper sanitation, insure maximum operating efficiency, and avoid the corrosive action of food fluids on metal parts that are left on for long periods of time. We recommend cleaning once a week.
Page 19
CASE CLEANING THIS DOCUMENT CONTAINS IMPORTANT INFORMATION ABOUT ® CLEANING YOUR ULTRAVISION ANTI-REFLECTIVE GLASS! PLEASE READ AND FOLLOW THESE INSTRUCTIONS TO PREVENT DAMAGE TO THE ANTI-REFLECTIVE COATINGS. ® SOVIS ULTRAVISION tempered glass specialized Anti-Reflective coatings on each surface of the glass. These coatings reduce the glare from lighting so that the products on display are more visible to your customers.
PARTS ORDERING Contact the Service Parts Department at: 319-293-3777 Provide the following information about the part you are ordering: • Model number and serial number* of the case for which the part is intended. • Length of the part (if applicable). •...
Page 23
WIRE INFORMATION WIRE INFORMATION BLACK REFR POWER BLACK TO BLOCK 4 - A 1 WHITE REFR POWER WHITE TO BLOCK 4 - E 1 WIRE INFORMATION WIRE INFORMATION BLACK TO LIGHT POWER BLACK TO BLOCK 4 - F 1 WHITE TO LIGHT POWER WHITE TO BLOCK 4 - H 1 WIRE INFORMATION WIRE INFORMATION...
Page 24
B1: DIXELL OPERATING INSTRUCTIONS dIXEL 1592002701 Operating instructions 4.2 DEHUMIDIFYING ACTION XH240L – XH240V The dehumidifying action is performed enabling the heating and compressor outputs together when humidity is higher than SET_RH+dbH value. Outputs are disabled when humidity comes back to the SET_RH value. TEMPERATURE AND HUMIDITY CONTROLLER 4.2.1 Relation between cooling, heating and dehumidifying If is simultaneously present a request of cooling (temp>SET_TEMP+dbt) and...
Page 25
B2: DIXELL OPERATING INSTRUCTIONS dIXEL 1592002701 Operating instructions MODE FUNCTION 5.8 ON/OFF FUNCTION °C By pushing the ON/OFF key, the instrument shows “OFF” for 5 sec. and the ON/OFF LED is switched ON. °F °C During the OFF status, all the relays are switched OFF and the regulations are The compressor is running stopped;...
Page 26
B3: DIXELL OPERATING INSTRUCTIONS dIXEL 1592002701 Operating instructions when this humidity is reached and after the AHd delay time the HHA alarm is enabled. 7.5 HEATING RELAY SAFETY (i1F=Ht) AHH Humidity alarm recovery differential: (0.5÷20.0) Intervention differential for recovery of With i1F=Ht as soon as the digital input is activated for “did”...
Page 27
B4: DIXELL OPERATING INSTRUCTIONS dIXEL 1592002701 Operating instructions Automatically the parameter list of the “Hot Key” is downloaded into the Controller 13.2 XH240V memory, the “doL” message is blinking followed a by flashing “End”. After 10 seconds the instrument will restart working with the new parameters. Remove the “Hot Key”..
Page 29
D1: PARTS LIST Cornice Fixed Front Glass Adjustable Shelf Bracket Stainless Steel Wire Shelf Bottom Deck SS Wire Riser Front Toekick Outside Front End Toekick Dry or Refrigerated Lower Storage End Panel Fixed End Glass Shelf Standard Outside Back Rear Load Doors Light Guard Upper-Interior Wire Grid Gravity Coil Location...
Hill PHOENIX, Inc. Hereinafter Referred To As Manufacturer LIMITED WARRANTY GENERAL WARRANTY Manufacturer’s products are warranted to be free from defects in materials and workmanship under normal use and maintenance for fourteen months from date of shipment from manufacturer (the “Base Warranty Period”). In the event of a qualifying warranty claim, a new or rebuilt part to replace any defective part will be provided without charge.
Page 31
Warning Maintenance & Case Care When cleaning cases the following must be performed PRIOR to cleaning: To avoid electrical shock, be sure all electric power is turned off before cleaning. In some installations, more than one switch may have to be turned off to completely de-energize the case.
Need help?
Do you have a question about the AGB and is the answer not in the manual?
Questions and answers