INSTALLATION INSTRUCTIONS | 31-00133
PCD7.LR-TR40 and PCD7.LR-TR42
LCD and non-LCD Wall Modules

BEFORE INSTALLATION

CAUTION
Erratic System Operation Hazard.
Failure to follow proper wiring practices can intro-
duce disruptive electrical interference (noise).
Keep wiring at least one foot away from large inductive loads such
as motors line starters, lighting ballasts, and large power distribu-
tion panels.
Shielded cable is required in installations where these guidelines
cannot be met.
Ground the shield only to the grounded controller case.
IMPORTANT
All wiring must comply with local electrical codes and
ordinances or as specified on installation wiring dia-
grams.
• For information on Sylk bus distance limitations,
see Table 1 on page 2.
• All wiring is polarity insensitive.

INSTALLATION

Mount the wall module on an inside wall approximately 1372 mm
from the floor (or in the specified location), to allow exposure to
the average zone temperature. Do not mount the wall module on
an outside wall, on a wall containing water pipes, or near air ducts.
Avoid locations that are exposed to discharge air from registers or
radiation from appliances, lights, or the sun.
The wall module can be mounted on a wall, on a standard utility
conduit box using 3.5 mm screws or on a 60 mm wall outlet box
(see Fig. 3). When mounting directly on a wall, use the type of
screws appropriate for the wall material.
Fig. 1. PCD7.LR-TR42
Mounting DIMENSIONS
Fig. 2. Subbase mounting holes and locking tabs (in mm).
60
60
60
81
31-00133-01
118
83

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCD7.LR-TR42 and is the answer not in the manual?

Questions and answers

Summary of Contents for SBC PCD7.LR-TR42

  • Page 1 INSTALLATION INSTRUCTIONS | 31-00133 PCD7.LR-TR40 and PCD7.LR-TR42 LCD and non-LCD Wall Modules BEFORE INSTALLATION INSTALLATION Mount the wall module on an inside wall approximately 1372 mm from the floor (or in the specified location), to allow exposure to the average zone temperature. Do not mount the wall module on an outside wall, on a wall containing water pipes, or near air ducts.
  • Page 2 2 | PCD7.LR-TR4x Wall Modules INSTALLATION INSTRUCTIONS | 31-00133 MOUNTING WIRING All terminal connections can be made to the backside of the STANDARD UTILITY CONDUIT BOX module. There are no field adjustable/replaceable components inside the module. SUBBASE Attach the wires from the programmable controller and network NO.
  • Page 3 (1-15). Use the bus address label, shown in Fig. 7, as a reference. TERMINALS AT ONE TERMINAL. The default address for both PCD7.LR-TR40 and PCD7.LR-TR42 is 1. The address on the wall module must match the address in the configuration tool.
  • Page 4 PG5 config tool. Fig. 9. PCD7.LR-TR42 Wall Module LCD Fig. 10. PCD7.LR-TR42 Wall Module LCD Fig. 11. PCD7.LR-TR42 Wall Module LCD display startup screen 1.

This manual is also suitable for:

Pcd7.lr-tr40

Table of Contents