Art Andersen CPH AACPH-RC1-EU Manual

Copenhagen blind wall controller

Advertisement

Copenhagen Blind Wall Controller
Copenhagen Blind Wall Controller
Productno: AACPH-RC1-EU
The Wall Controller is a multi-function button which is able to
control the position of a blind and switch appliances on/off. The
control the position of a blind and switch appliances on/off. The
Wall Controller consists of a wall bracket and a portable
The portable controller has an integrated magnet which gives the
The portable controller has an integrated magnet which
user the possibility to place it in the wall bracket or on any metallic
surface. This product can be included and operated in any Z-
surface. This product can be included and operated in any Z
TM
Wave
network with other Z-Wave
manufacturers and/or other applications.
The rotation function to control position of blind works when
to control position of blind works when the
controller is fitted upright or stick on the wall
is fitted upright or stick on the wall, in all other
situations the controller will work only as a binary switch.
Please provide a 5 DVC voltage through Micro USB Port to
Please provide a 5 DVC voltage through Micro USB Port to
wake the device up before the first using.
Function button which is able to
portable controller.
in the wall bracket or on any metallic
TM
certified devices from other
certified devices from other
as a binary switch.

Z-Wave Network operation

Wave Network operation
Auto inclusion: (add using Network Wide Inclusion)
primary controller in inclusion mode then press the Button
primary controller in inclusion mode then p
once.The LED pointer will flash red up to 30 seconds while it waits
The LED pointer will flash red up to 30 seconds while it waits
to be included. When successfully included it will turn on a green
to be included. When successfully included it will turn on a green
surround light for 1 second.
Manual inclusion:(add using Network Wide Inclusion)
primary controller in inclusion mode. With the wall controller
primary controller in inclusion mode
vertical, point the LED pointer to area A (shown in Fig. 1) and
press the Button three times within 1.5 seconds.
three times within 1.5 seconds. The LED pointer
will flash red up to 30 seconds while it waits to be included. When
will flash red up to 30 seconds while it waits to be included. When
successfully included it will tu
second.
Exclusion:(remove) Set the primary controller in exclusion mode.
Set the primary controller in exclusion mode.
With the wall controller vertical, point the LED pointer to area A,
With the wall controller vertical, p
then press the Button three times within 1.5 seconds.
utton three times within 1.5 seconds. The LED
pointer will flash red once. When successfully excluded it will enter
pointer will flash red once. When successfully excluded it
a 30 seconds auto inclusion mode and the LED pointer will flash
a 30 seconds auto inclusion mode
red.
Reset to default:With the wall controller vertical, point the
With the wall controller vertical, point the LED
pointer to area A then press the Button four times within 2
pointer to area A then press the
seconds and hold at fourth. The red LED pointer will light for 5
seconds and hold at fourth. The red LED
seconds, release the button within 2 seconds while the LED goes
seconds, release the button within 2 seconds while the LED goes
out. The LED will flash for 1 second if reset succeeded, or LED will
out. The LED will flash for 1 second if reset succeed
flash once if not succeeded.
Note: Use this procedure only in the event that the primary
Use this procedure only in the event that the primary
1
using Network Wide Inclusion)Set the
using Network Wide Inclusion) Set the
pointer to area A (shown in Fig. 1) and
rn on a green surround light for 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AACPH-RC1-EU and is the answer not in the manual?

Questions and answers

Summary of Contents for Art Andersen CPH AACPH-RC1-EU

  • Page 1 Copenhagen Blind Wall Controller Copenhagen Blind Wall Controller Z-Wave Network operation Wave Network operation Productno: AACPH-RC1-EU Auto inclusion: (add using Network Wide Inclusion) using Network Wide Inclusion)Set the primary controller in inclusion mode then p primary controller in inclusion mode then press the Button once.The LED pointer will flash red up to 30 seconds while it waits...
  • Page 2 controller is lost or otherwise inoperable. • Rotation Function When rotated in vertical position (mounted in the wall bracket), the wall controller will send a value between 0 and 99 depending on how it is rotated to association group 2. The value is sent after a small delay to be sure that the user has stopped rotating the device.
  • Page 4 Association time. Configuration This device supports 2 association groups and each group can be associated with eight nodes. To build/disable association between Name Size Def. Valid Description devices. (Byte) Values 1. Have the Z-Wave controller entered association mode. Control the value 2.
  • Page 5 RF Range Minimum 40 m in door, 100m outdoor line of sight Supported Z-Wave Command Classes Operating Temperature -10°C ~ 45°C Frequency Range AACPH-RC1-EU (EU): 868.40MHz; 69.85MHz(EU) * COMMAND_CLASS_ZWAVEPLUS_INFO_V2 AACPH-RC1-US: 908.40MHz; * COMMAND_CLASS_BATTERY 916.00MHz(USA/Canada) / * COMMAND_CLASS_CENTRAL_SCENE_V3 AACPH-RC1-TW: 922.5MHz/ 923.9MHz/ * COMMAND_CLASS_VERSION_V2 926.3MHz (Taiwan/JP)
  • Page 6 Disposal This marking indicates that this product should not be If this equipment does cause harmful interference to radio or tele- disposed with other household wastes throughout the vision reception, whichcan be determined by turning the equip- EU. To prevent possible harm to the environment or ment off and on, the user is encouraged to try to correct the inter- human health from uncontrolled waste disposal, ference by one of the following measures:...

Table of Contents