Orangewire System OW-503-4 Operating Instructions Manual

4 channel power switch

Advertisement

Quick Links

 
 
 
 
 
Operating Instructions 
OW-503-4
 
4 Channel Power Switch 
 
 
 
 
 
 
1
www.orangewiresystems.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OW-503-4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Orangewire System OW-503-4

  • Page 1: Operating Instructions

              Operating Instructions  OW-503-4   4 Channel Power Switch              www.orangewiresystems.com...
  • Page 2 (I < 100mA), a high accuracy shunt provides microamp current sense data to measure battery drawdown.    The OW-503-4 is designed for the National Instruments (NI) Switch Load Signal Conditioning (SLSC) system, to be used in  Hardware-In-the-Loop (HIL) simulators. This card is used to test prototype or production Electronic Control Units (ECUs or ...
  • Page 3                 www.orangewiresystems.com...
  • Page 4 Absolute Maximum Ratings  Operating Current Measurement Range  ±55A  Power-down Maximum Current   100mA  Operating Maximum Continuous Current  40A (fused)  Input Signal Voltage  200V  Reference Output  20A/Rail    Operating Specifications  General  Number of Channels  4  Reference Power Connectivity  12 position, 41A, 7.62mm Phoenix  Operating Current Sense Technology ...
  • Page 5             www.orangewiresystems.com...
  • Page 6: Front Panel Connections

    Signal Description  OW-503-4 has four relays on it. All four relay common terminals are connected to the “IN” pins. All “IN” pins are connected to each  other. Relay normally open pins are connected to the ”OUT” pins. “COM” pins are connected to each other, and are not switched. ...
  • Page 7: Rear Panel Connections

    Sleep Mode Current  OW-503-4 has 4 channels, each with a so ware enabled 10Ω shunt for detecting current when the DUT is in power-down or “sleep”  mode. Each shunt has a positive and negative end, and both ends are available on the rear panel and can be connected to a fully ...
  • Page 8 Pinouts  Signal Midplane Pinout for OW-503-4 (Identical for all 12 card positions)      *Lab Ground if PXI jumpers on OW-503-4 are connected.       www.orangewiresystems.com...
  • Page 9: Reference Connections

    Reference Connections  OW-503-4 brings all 8 references from the OW-130 Signal Midplane. Jumper wires are used to make connections between the IN,  OUT, or COM signals and the Signal Midplane Reference Rails. To switch power to a Midplane Reference Rail, connect the output ...
  • Page 10   www.orangewiresystems.com...
  • Page 11: Theory Of Operation

    Theory of Operation  OW-503-4 is designed to switch power to devices under test, or to the Signal Midplane power rails. Each channel has a 40A,  so ware enabled relay. Relay common for all channels is connected to the IN net. Relay normally open is connected to the output ...
  • Page 12 PXI Jumpers  The OW-503-4 can be used with multiple real time NI Analog to digital conversion modules and multi-meters. Because many of  these modules have di erent pinouts and grounding patterns, the OW-503-4 has jumpers B1-B3 to enable compatibility with all ...

Table of Contents