How to Use the Wall Plate Controller..................10 b. Connecting to a Touch Screen Controller (External Controller)..........11 9. Accessory Installation..........................11 10. Cable Management..........................12 11. Setting the Show Position........................13 12. Maintenance and Adjustments.......................14 13. Troubleshooting............................15 SVS 12HSE Lift Installation Instructions Page 2 of 16...
3. SVS 12HSE LIFT WARRANTY SVS, Inc. 's limited warranty only covers failures due to defects in materials or workmanship that occur during normal use. This limited warranty DOES NOT cover failures resulting from accident, misuse, abuse, neglect, mishandling, misapplication, faulty or improper installation and set-up adjustments, improper maintenance or alteration.
Do not remove the lift's shipping blocks until instructed to do so in Section 7. SVS scissor lifts are shipped in a slightly open position to eliminate stress on the limit switches and to maintain a tight cable pack on the cable drum. If physical height measurements are taken before the blocks are removed from the Lift, they may not accurately reflect the height of the closed Lift.
• screen. Consider if the lens is offset from the center of the projector and thus the center of the Lift. Figure 2. SVS 12HSE Front & Side Views 6. LIFT SUPPORTING STRUCTURE The SVS 12HSE Lift should be mounted from six 1/2”...
Page 7
Figure 6 Recommended Lift Support Structure for Flat Ceilings. This allows for front-to-back and side-to-side adjustments of the Lift for alignment to the screen. Figure 5a. Recommended Lift Support Structure for Flat Ceilings SVS 12HSE Lift Installation Instructions Page 7 of 16...
Important When attaching the Lift to a flat concrete ceiling, SVS suggest two (2) pieces of P1000T Unistrut (or equivalent) approx. 10-feet (3.04 m) long, to be installed on the ceiling first. Proper spacing between the two pieces will be based on the distance between the four (4) mounting holes of the Lift as shown in Figure 4.
Page 9
If the cable spills over the cable drum and the Lift is not stopped the cable will back-wind onto the cable drum causing severe damage to the Lift and accessories. 8. ELECTRICAL CONNECTIONS SVS 12HSE Lift Installation Instructions Page 9 of 16...
Electrical connections should be made at this time. The SVS 12HSE requires 220V/50Hz at 1.2 Amps and is supplied with a six foot power cord. The SVS 7 Lift is controlled with a 24VAC Low Voltage Controller called the Wall Plate Controller. This controller can easily be connected to external controllers like Crestron, AMX, Extron, etc.
3. Program an exclusive lockout on up and down so that both cannot be activated at the same time. (Note: SVS Lifts have a lockout function that disables the Lift when it receives a up and down command at the same time.
Figure 11. Dual Accessory #7 Cable Retractor are standard equipment on all SVS 12HSE Series Lifts. The Cable Retractors are a spring-loaded reel on the rear of the Lift. The retractor automatically retracts your cable as the Lift ascends and releases your cable as the Lift descends.
6. The Lift will only stop at the Show position when lowering from above the Show position and not when rising from below the Show position. 7. The Show position is adjustable with an accuracy of /- 1/8-inch (0.32 cm). 13. MAINTENANCE AND ADJUSTMENTS SVS 12HSE Lift Installation Instructions Page 13 of 16...
Page 14
Figure 13. Lift Part Locations SVS 12HSE Lift Installation Instructions Page 14 of 16...
Here are a few common and simple things to check. If at anytime you are unsure of the check, please contact SVS, we will be happy to help you troubleshoot your problem.
Page 16
Controller to the up limit microswitch. Lift stopped working after being External controllers can not be used Contact SVS to disable the 12Volt connected to an external controller with Accessory #15 12Volt Trigger. Trigger Wall Plate Controller key switch in...