Download Print this page

Flextest FL2005.1 Instruction Manual

Multifunctional tester

Advertisement

Quick Links

FLEXTEST Multifunctional Tester
CONTENTS
Title
Page
FL2005.1
....
..............................................1
2. SPECIFICATIONS ...........................................................2
3. PARTS & CONTROLS......................................................4
..................................................7
....
5.
V VOLTAGE MEASUREMENT...................................9
RESISTANCE MEASUREMENT...............9
.....
................................................9
9. BATTERY REPLACEMENT...........................................11
10. MAINTENANCE & CLEANING.....................................11

Advertisement

loading

Summary of Contents for Flextest FL2005.1

  • Page 1: Table Of Contents

    FLEXTEST Multifunctional Tester CONTENTS Title Page FL2005.1 1. SAFETY INFORMATION ..........1 INSTRUCTION MANUAL 2. SPECIFICATIONS …............2 3. PARTS & CONTROLS............4 4. BEFORE OPERATION ..........7 ..V VOLTAGE MEASUREMENT......…..9 6. F RESISTANCE MEASUREMENT...…..…..9 LOOR ROBE 7. H RESISTANCE <1000Ω EATING ABLE ..
  • Page 2: Safety Information

    1. SAFETY INFORMATION 2. SPECIFICATIONS The circuit under test must be de-energized and isolated before 2-1 General Information connections are made except for voltage measurement. Environment conditions : Verify operation prior to measuring hazardous voltages (voltage Installation Categories III 1000V above 30V AC rms, 42V AC peak and 60V DC).
  • Page 3: Parts & Controls

    2-2 Electrical Specifications ~V AC Voltage (40Hz~500Hz) Accuracies are specified as: Overload Range Resolution Accuracy Input Impedance ±(...% of reading + ...digits) at 23℃ ±5℃,below 80% RH. Protection 999V 2%+3 9MΩ 1000Vrms Insulation Resistance (MΩ) Sensitivity : 2V Range Resolution Accuracy Test Voltages V DC Voltage...
  • Page 4 LCD display. Display : MEM key: Manual data memory control key. LOCK key: Locks the test Insulation Resistance (MΩ). a) Press and hold down LOCK key than press TEST key enter to continuously MΩ test mode, the “LOCK ” icon appear on the display.
  • Page 5: Before Operation

    4-4 Manual Data Memory and Read Mode : 4. BEFORE OPERATION 1) Clear the manual memorized data Set the function switch to OFF position to turn off the meter. Warning Press and hold down "MEM" key, and turn on the meter. Release the "MEM"...
  • Page 6: Voltage Measurement

    V VOLTAGE MEASUREMENT 8. MΩ INSULATION RESISTANCE MEASUREMENTS 1) Set the function switch to V position. 8-1 Measuring Insulation Resistance Measuring insulation resistance requires the application of 2) Connect red test lead to “ VΩ ” terminal and black test lead to potentially dangerous voltage to the circuit.
  • Page 7: Battery Replacement

    In this mode, if the probes are disconnected from the circuit, the meter cannot discharge any potentially dangerous capacitive voltages left on the circuit. Ensure that the circuit is de-energized before connecting the test probes. 2) Press LOCK or TEST key to disable the Lock function. 9.