99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com RH10UC SD To HD Upconverter R-series Card Module User Manual Revised April 5, 2006 Software Version 2.3 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176...
Limited Warranty AJA Video warrants that this product will be free from defects in materials and workmanship for a period of five years from the date of purchase. If a product proves to be defective during this warranty period, AJA Video, at its option, will either repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
Page 3
• Separate multipoint H and V filters • Motion adaptive interpolation • 16 bit coefficients, 16 bit internal data paths • Accurate 16 bit SD to HD colorspace conversion • 1 slot AJA FR1 or FR2 frame Upconverter Specifications Item Specification...
After actuation, either switch will return to a middle position. If you move a switch and hold it in place (left or right), the RH10UC will sense this and auto-increment or decrement.
Page 5
HF—High Definition Framesync Editing and Viewing Board Settings Adjust Mode Moving the PS switch in either direction causes the RH10UC to enter adjust mode . When this happens, the display will change to indicate the parameter being shown/edited. Character #...
Changing Operating Modes Changing the selection in Param 0 from “UP” to “HF” selects the operating mode of the board and results in alternate sets of parameters and definitions. The two tables that follow show the parameter choices and definitions available when the board is in Upconvert or HD Framesync mode. Making a change in Param 0 results in an alternate bitfile to be loaded and the HD Framesync H and V output timing params to be loaded into the registers.
Page 7
The factory defaults are zero-timed values as measured empirically at AJA. They are given in the table below. The RH10UC remembers H and stores it in flash, recalling it as needed when the output frame rate or geometry changes. Refer to the H and V Parameter Reference Table appearing later in this manual for value ranges.
Page 8
(“0”). Zero is the factory default for both V timing parameters. The RH10UC remembers V and stores it in flash, recalling it as needed when the output frame rate or geometry changes. Refer to the H and V Parameter Reference Table that follows for ranges.
Page 9
The RH10UC cell group of 9 BNCs contains two BNCs that can be used for a looping reference connection. If this method is used, then the reference select setting on the RH10UC should be set to “LOOP” and the TERMINATION setting should be set to “OFF” (no termination). Optionally, if you're using only one of the looping reference BNCs, then the TERMINATION setting should be set to “ON.”...
Page 10
RH10UC Aspect Ratio Modes 4:3 Upconverts To These displays on 16:9 Full Screen "Anamorphic" 16:9 "Letterbox" 14:9 Wide Zoom Visit us at www.TestEquipmentDepot.com Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com...