System Troubleshooting; Troubleshooting Guide - BreezeCOM AP-DS.11 User Manual

Breezenet ds.11 series. wireless base station/bridge client
Table of Contents

Advertisement

Appendix A. Radio Signal Propagation

3. SYSTEM TROUBLESHOOTING

The following troubleshooting guide provides answers to some of the more
common problems which may occur when installing and using BreezeNET DS.11
Series products. If problems not mentioned in this guide should arise, checking the
Ethernet and WLAN counters may help (see Section Error! Reference source not
found.). If the problem persists, please feel free to contact your local distributor or
the BreezeCOM Technical Support Department.

3.1 Troubleshooting Guide

Problem and Indication
No Power to Unit. Power
LED is off.
Failure to establish wireless
link. Association LED is off
and unit resets every few
minutes.
User's Manual
Possible Cause
1. Power cord is not
properly connected.
2. Power supply is
defective.
1. Power supply to units
may be faulty
2. The units may not have
the same ESSID as the
AP-DS.11.
A-14
Corrective Action
1. Verify power cord is properly connected
to the BreezeNET unit and to the power
outlet.
2. If this is not the cause, replace the power
supply.
1. Verify power to units.
2. Verify that all units in the network have
the same ESSID as the AP (ESSID must be
identical in all units in the network):
Verify wireless link:
Set AP-DS.11 and Bridge unit side by side.
Power on each unit and see if a wireless link
is established (even "D" models without
their external antennas should establish a
link if placed side by side with the AP-
DS.11).
If the units fail to associate, reset units to
factory default values reset unit (see Section
2.2). The units should now establish a
wireless link.
BreezeNET DS.11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-ds.11