3.1 Troubleshooting Guide
Problem and Indication
No Power to Unit. Power
LED is off.
Failure to establish wireless
link. Association LED is off
and unit resets every few
minutes.
User's Manual
Possible Cause
1. Power cord is not
properly connected.
2. Power supply is
defective.
1. Power supply to units
may be faulty
2. The units may not have
the same ESSID as the
AP-DS.11.
A-14
Corrective Action
1. Verify power cord is properly connected
to the BreezeNET unit and to the power
outlet.
2. If this is not the cause, replace the power
supply.
1. Verify power to units.
2. Verify that all units in the network have
the same ESSID as the AP (ESSID must be
identical in all units in the network):
Verify wireless link:
Set AP-DS.11 and Bridge unit side by side.
Power on each unit and see if a wireless link
is established (even "D" models without
their external antennas should establish a
link if placed side by side with the AP-
DS.11).
If the units fail to associate, reset units to
factory default values reset unit (see Section
2.2). The units should now establish a
wireless link.