Getting started

Vibration

At all times the data logger must be protected against vibrations. These vibrations can harm the
performance of the data logger. Especially the real time clock can be harmed by long-lasting vibrations

Do's and Don'ts

Do's
-
Always provide a dry and clean environment when you open the case of a data logger,
-
When you open the case, use a Philips screwdriver of 2mm for loosening the screws,
-
Protect the data logger against mechanical stress and vibrations
Don'ts
Don't try to use a plain screwdriver for loosening the screws, you will damage the screws,
-
-
Avoid touching the PCB directly.

Inserting the SIM-card

The wireless data functions will only work when an activated SIM, with a valid subscription is placed in the
data logger. In the menu the configuration and network settings must also match to those supplied by the
SIM card provider. The pin code of the SIM card must be removed prior to insertion in the data logger. To
prevent problems with the SIM card it can be inserted in a mobile phone or 2G/3G data modem. In a Mobile
phone or 2G/3G modem the 2G/3G, SMS and GSM data functionality can be tested.
When you have obtained a 2FF SIM-card, you can insert it into the SIM-card-holder.
Beware:
Remove the PIN code (this can be done with the use of a mobile phone),
Check the settings of your mobile provider,
Check the settings for communicating via HTTP, FTP, E-mail or TCP,
Check the capability of data communication for your service-provider,
Make sure the SIM-card is installed correctly, and not upside down.
The Oblique side of the card should be visible. (see picture).
Installation of the SIM card needs to be done in a clean and dry
environment.
Avoid contact with the electronic parts around the SIM card.
Remove power before changing or inserting a SIM card.
The same applies to the SD-card.
Manufacturers of low power instruments
DATA LOGGER MANUAL
page 16