shutdown diagnostics
The unit has the ability to report the cause of the last shutdown of the remote start system. To enter diagnostic mode:
1.
Turn the ignition off.
2.
Press and HOLD the Program switch.
3.
Turn the ignition on and then off.
4.
Release the Program switch.
5.
Press and release the Program switch.
The LED will now report the last system shutdown by flashing for one minute in the following grouped patterns:
LED
FLASHES
One
Two
Three
Four
Five
Six
Seven
Eight
The LED will stop flashing when the ignition is turned on.
© 2001 Directed Electronics, Inc. Vista, CA
SHUTDOWN
MODE
System timed out
Over-rev shutdown
Low or no RPM
Transmitter Shutdown (or optional push-button)
(-) Shutdown
(+) Shutdown
(-) Neutral safety shutdown (H2/6 BLACK/WHITE)
Wait-to-start timed out
35