GranView Clean Burning Zero Clearance Fireplace Installation and Operation Instructions Keep these instructions for future use 9608 State 371 NW 800-367-7976 wilkeningfireplace.com Walker, MN 56484...
Page 2
Chimney Height, Offset and Clearance Requirements ....................... 6 Combustion Air Requirements............................7 Framing Specifications ..............................8 Mobile Home Installation Requirements ........................... 8 Doors for the GranView ..............................9 Heated Air Ducting Options ............................. 9 Clean Face Kit .................................10 Facing .....................................10 Blower Installation and Electric Wiring Diagram .......................11 Unit Diagrams ................................
This will eliminate the chance of electrical shock. This fireplace must be installed with a chimney system that is 10. Wilkening Fireplace Co. is not responsible for any smoking issues listed in the Chimney Section of this manual. due to inadequate draft or poor burning which results from lack of combustion air or chimney draw.
Clearances and Height Requirements The GranView may be placed directly on wood flooring – all carpet or vinyl must be removed. The outside air kit, fire stop spacer and roof flashings may be placed directly on or next to normal construction materials.
Hearth Extension Requirements The GranView can be installed on a raised hearth provided there is a minimum of 72” measured between the fireplace base and finished ceiling for front louver heat venting or 80” if using dual or single top vent ducting of heated air. Raised hearths must extend 16”...
Chimney Requirements The GranView requires an 8” diameter chimney. Any factory built chimney listed to UL-103HT may be used. The use of one brand of chimney is required. Do not mix components from several manufacturers as this may cause a fire hazard.
Combustion Air Requirements The GranView fireplace is designed to use outside air to supply each and every combustion air port inside of the fireplace. This creates a sealed system for air supply, eliminating fireplace odor due to negative pressure in the home. The supply air hook up is located on the lower left of the fireplace as you face it.
Enclosure Framing The framing of the fireplace enclosure must not infringe on the area above the fireplace unit to ceiling level. The only combustible material permitted in this space is a header at the front supporting the face above the opening, and this must not be closer than the metal stand-off.
Heated Air Ducting Options The GranView comes standard with a heat outlet at the top of the unit and a room air inlet at the base. Several louver designs are available to finish these openings. This fireplace may also have a separate vent or vents, ducted from the pre-cut holes in the top of the unit, to areas, next to or behind the installation and may be used in conjunction with or without the vent out the front.
Front vent only Front vent with Dual top vents Front vent with dual top vents No front vent single top vent Clean Face Option (See diagram on page 14) The clean face option allows the elimination of the air inlet louver that is located directly below the doors in the unit face.
Page 11
NOTE: A tight seal must be created between the metal fireplace face and the facing material to prevent heat from flowing between them. This seal is typically created by the scratch coat of mortar that is applied over the facing kit which allows the facing material to bond to it. When installing sheet rock to the sides of the unit face, leave a 3/8”...
Unit Specifications Top stando Top stando ” 2 ½” ” 4 ½” ” 5 ½” 21 ½” 21 ½” F R O N T T O P 37” 37” 8 ¼” 8 ¼” 8 ¼” 8 ¼” ” 11 ⁄ ” Top stando Top stando Top stando...
Page 13
6” minimum to louver Shown with 18 ¼” 11 ⅞” optional top vent Louver framing 12” 11 ⅞” Louver 72" minimum chase height with front louver, 61 ½” 80" minimum minimum with top vents with a 4” tall mantel Finished that is 8”...
Page 14
Top vents can go to Top vent kit front, side or back of Upper steel ba e the replace chase with holes Ba e support tabs Ba e #7 Air tubes Angle refractory Seal this area (part #5) Use facing kit (part # CFFK) 8”...
Page 15
Center to center of Complete chimney as per chimneys manufacturers instructions. as shown Fire stop radiation shield 36” shown. An attic insulation shield may be required for your installation. Consult dealer. Ceiling 59” wide as shown NOTICE: If ducting of outside combustion air to the rear of this 96”...
Page 16
Refractory Liner and Baffle Assembly The GranView utilizes a super reflective inner lining of Skamol. These panels protect the metal surfaces and increase the operating temperature of the burning chamber. The diagram below shows the placement of this liner and upper baffles. Care must be taken when handling these pieces as not to damage them.
Installation of the GranView Select the appropriate location for the fireplace, see page 5. If a raised hearth is used, build the platform for the unit to rest on and frame the structure/chase; cutting or creating the openings required for air supply, chimney routing, heat dump kit and the top venting option if needed.
Page 18
Contact your dealer or Wilkening Fireplace Co. for proper replacement parts. To replace the glass remove the screws from the outside perimeter of the glass frame, lift the U channels with gasket out and clean any fragments before reinstalling the new glass.
To clean the glass, use an ammonia based cleaner, locally available fireplace glass cleaners or Speedy White. Contact your dealer or Wilkening Fireplace Co. to obtain Speedy White glass cleaner. Take care not to apply the cleaner in a manner that it contacts painted areas or electroplated surfaces as discoloration may occur.
Back Smoking To minimize smoke from entering the room when refueling, crack both doors open slowly at the same time and refuel. Excessive amounts of fuel or wet fuel will also create the potential for back smoking when the door is open due to over capacity of burning fuel or low draft due to low firebox temperature.
the base of the unit. Do not use a grate or andirons to elevate the fire. Place dry kindling on top of the paper and logs in a crisscross fashion, leaving room for air to flow between them. Light the paper and leave the door ajar for 8-10 minutes. This will induce a draft in the chimney and start the wood burning.
Page 22
• Never plug the outside air supply. Unlike “normal” zero clearance fireplaces, the GranView fireplace cannot leak cold air into the home due to our totally sealed air connection and air tight doors on the unit.
Replacement Parts Description Part Number Inner Liner Components (see diagram) Stainless Bottom GV-01/GV-02 “U” Connector 2 piece back GV-03 4- Lower side panels (each) GV-04 Back Angle liner GV-05 Upper side liner (each) GV-06 Top Tube Refractory (2 pc.) GV-07 Door Gasket kit 7/8”...