  • Page 1 DMS-OUT Owner’s Manual Universal Remote Control www.UniversalRemote.com...
  • Page 2 For software downloads, training materials, and frequently asked questions. Contact Support: Rear Panel............2 Total Control is a URC product sold through Authorized Dealers, for questions or assistance contact you Custom Installer/Programmer (write in Top Panel & LED States........4 the company name, email, and contact info): Bottom Panel............5...
  • Page 3: Features And Benefits

    The DMS-OUT, similar to the URC Audio Sensor (SEN-AUD), can detect an audio signal which can then trigger n activity (macro). ● Flexible Power Source Use the supplied 5V DC power adapter or take advantage of the DMS-OUT’s PoE (Power Over Ethernet) capability using a CAT 5/6 wiring. Parts & Pieces...
  • Page 4: Rear Panel

    DMS-OUT Owner’s Manual Rear Panel: 5V DC Input: Provides power to the DMS-OUT. PoE may be used as a substitute. Analog Input: Standard RCA (analog) connector. Digital Input - Optical: This input uses standard S/PDIF OPTICAL TOSLINK connector. Note: The DMS-OUT converts Dolby Digital 5.1/DTS 5.1 to a DMS Stream.
  • Page 5 DMS-OUT Owner’s Manual Digital Input - Coax: Standard RCA (analog) connector, this receives bitstreams of audio data. Note: The DMS-OUT converts Dolby Digital 5.1/DTS 5.1 to a DMS Stream. LAN Port: This 10/100 Ethernet port supports PoE and sends the URC Audio stream through the local network, this is also how the DMS-OUT receives commands and sends audio.
  • Page 6: Top Panel & Led States

    DMS-OUT Owner’s Manual Top Panel & LED States: There are three (3) LED lights at the top of the DMS-OUT which can provide users with basic troubleshooting information. Status LED ● Off Unit has not been programmed with a Total Control file.
  • Page 7: Bottom Panel

    Unit is connected to the local network and has an IP address. Bottom Panel Located beneath the DMS-OUT is a Reset button. The Reset button is recessed so a paperclip or something similar is required to press. This button allows for: ●...
  • Page 8: Wiring The Dms-Out

    DMS-OUT Owner’s Manual Wiring the DMS-OUT In order for the DMS-OUT to provide the best possible experience, it must be first wired correctly then programmed by a Total Control Certified Installer. Follow these steps to prepare the DMS–IN for programming: 1.
  • Page 9: Specifications

    DMS-OUT Owner’s Manual Specifications Microprocessor: Cortex-A5 600MHz Memory: 128MB NAND, 128MB RAM Network: One 10/100 Ethernet port (PoE) Weight: 5.8oz Size: 4.6” x 4.6” x 1.2” Power: Standard PoE Injector or PoE Switch (purchased separately), DC 5V/1A Page 7...
  • Page 10: Limited Warranty Statement

    DMS-OUT Owner’s Manual Limited Warranty Statement 1. Limited Warranty and Disclaimers Universal Remote Control, Inc. (“URC”) warrants that the URC equipment shall be free from defects in material and workmanship under normal usage for one (1) year from purchase when such is purchased from URC.
  • Page 11 DMS-OUT Owner’s Manual FITNESS FOR A PARTICULAR PURPOSE. URC DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF, OR THE RESULTS OF THE USE OF, THE EQUIPMENT, SOFTWARE OR DOCUMENTATION IN TERMS OF CORRECTNESS, ACCURACY, RELIABILITY OR OTHERWISE. EXCEPT AS EXPRESSLY PROVIDED FOR HEREIN, TECHNICAL SERVICES ARE SUPPLIED “AS IS”, WITHOUT...
  • Page 12 URC equipment sold by unauthorized resellers. With the exception of URC’s IR-only, broad-based consumer remotes, none of Page 36 URC’s PC programmable remotes or any of our Total Control® whole- house equipment are authorized for online internet sales. Buying URC’s PC programmable remotes or any of our Total Control®...
  • Page 13 DMS-OUT Owner’s Manual 2. URC’s Limitations of Liability IN NO EVENT SHALL URC BE LIABLE FOR INDIRECT, SPECIAL, INCIDENTAL, EXEMPLARY, PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND OR LOSS OF PROFITS OR BUSINESS OPPORTUNITY, EVEN IF URC IS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
  • Page 14: End User Agreement

    DMS-OUT Owner’s Manual End User Agreement The terms and conditions of the End User Agreement available at www.universalremote.com/eua.php shall apply. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 15 DMS-OUT Owner’s Manual Warning! Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Note: The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
  • Page 16 ● Emission :EN 55032 ● Immunity :EN 55024, EN55020 ● Power :EN-61000-3-2, 3 ● Declaration of Conformity “Hereby, Universal Remote Control Inc. declares that this DMS-OUT is in compliance with the Essential requirements: Certification Type No.(Model No.) DMS-OUT Batch/Serial No.
  • Page 17: Declaration Of Conformity

    DMS-OUT Owner’s Manual Declaration of Conformity Company Name Universal Remote Control Inc. Company Address 500 Mamaroneck Avenue, Harrison, NY 10528, U.S .A www.universalremote.com Contact Information Phone: (914)835-4484 F ax: (914)835-4532 Brand Name UNIVE RS AL remote control Product Name Stream Injector Output Device...