User Manual Instant Water Ionizer KYK IONIZER 777...
Page 2
The Manual will help you use the Product in correct and effective ways so that you could make the best of the Product. KYK shall continue to strive for the best of your benefit, health and happiness. Please do not hesitate to contact us should you experience any inconvenience or have any suggestion during use of the Product.
Page 3
Table of Contents Advantages of KYK Ionizer Parts and Components Product Configuration Name and Function of Each Part Front Panel of the Main Body Control Panel Caution before Installation Installation How to Use LED Display and Status How to Operate...
Page 4
Advantages of KYK Ionizer ❶ The world first instant hot/cold water dispenser ❷ The world first auto cock storage system ❸ 99.999% automatic sterilization ❹ System that cuts off all the sources of germs ❺ Solving the source of cock virus problem by removing the water tank ❻...
Advantages of KYK Ionizer Advantages of KYK Ionizer Components Feed Water User Manual Power Cord Water Tray Corporation Cock Reagent (for pH Compressed Fitting Stopper Elbow Fitting measurement) rubber Hose ※ Parts sold separately 4.5cm 1.5cm Pressure (Reducing) Dust Filter...
Product Configuration Overall Structure ~ Top ₩ ~ Left ₩ ~ Right ₩ ~ Front ₩ 487mm 300mm 465mm ~ Back ₩ ~ Bottom ₩...
Page 7
Name and Function of Parts Front Panel of the Main Body ❶ Display ❷ Function Selection Buttons ❸ Water Dispensing Cock ❹ Water Dispensing Button ❺ Water Tray ❶ Display : The case forming the exterior of the Product with all parts fitted ❷...
Name and Function of Parts Control Panel Central Cock Display ❶ Display ❷ Cold water ❸ Hot water ❹ Filter 1 Status ❺ Filter 2 Status ❻ Filter 3 Status ❼ Filter 4 Status Front Panel of the Main Body ❽...
Page 9
❶ Display : It displays the current use and setting of each application. ❷ Cold water : Select 'Cold Water' to dispense cold water. The button illuminates during dispensing to indicate that the Product dispenses cold water. ❸ Hot water : Select 'Hot Water' to dispense hot water. The button illuminates while dispensing to indicate that the Product dispenses hot water.
Page 10
Name and Function of Parts Back view Cooling tank air exhaustion valve: use only during first installation, lock after installation Turn left - open / Turn right - lock Over 10cm F F aucet aucet con conne nection ction (if faucet is used) Cooling tank drain connection (must be used...
Page 11
Left Filter Door Manual valve cap Bottom Water tray rubber foot Rubber foot Filter Door : To open and close after filter replacement Manual valve cap : To fit a manual valve if required Water tray rubber foot : To support the water tray Rubber foot : To support the main body...
Caution before Installation of the Product Caution before Installation Please observe the following before installation. Keep a gap of 10cm or more from Install the Product on solid and level the walls. ground. Cold water pipe Keep away from moisture, water The raw water hose must be connected to the cold water pipe.
Installation of the Product Installation Back view after installation Cooling tank air exhaustion valve: use only during first installation, lock after installation Turn left - open / Turn right - lock Over 10cm F F aucet aucet con conne nection ction (if faucet is used) Cooling tank...
Page 14
Installation Fit in the other end of the 6Ø(1/4 inch) hose connected to the Feed Water Corporation Cock, to the fitting at the end of the green hose (Raw Water Inlet Hose). Connect the drain hose to the fitting at the end of the Drain Outlet Hose (Orange).
Page 15
Touch the button to clean the Product. (Cleaning for 300 seconds) Upon cleaning, the Button is lit on, and letters are displayed in the central Cock Display window. Turn (open) the Intermediary Valve (Blue) anticlockwise to fill the Cooling Anticlockwise Tank.
Page 16
Installation Touch the Continuous Button to fill cold water. The Button flickers while water is filled, and is turned off when water is completely filled up. Now the Product is in the Standby Mode. Turn (close) the Intermediary Clockwise Valve (Blue) clockwise on bottom-right side at the back of the Product.
Page 17
Press the dispensing PUSH button with a cup to dispense water until changes to in the central Dispending Cock Display window. This will initiate the hot water heater to heat water. Once the display reads the setting for hot water is completed. ※...
Page 18
How to Use LED Display and Status PUSH (출수버튼) Cold alkaline water Level 1 Alkaline water Level 1 Purified water PH8.5 PH8.5 PUrI Cold alkaline water Level 2 Alkaline water Level 1 PH9.0 PH9.0 Alkaline water Level 1 Hot water PH9.5 Alkaline water Level 1 PH1.0...
How to Operate To dispense cold alkaline water Touch the Cold Alkaline Water Button and the Button will be lit on with the display of pH level in the Display Window. Also the blue lamp is lit on the Cold Water Display. Press the PUSH (Dispensing Button) button with a cup and the Dispensing Cock will protrude to dispense cold alkaline water with an audible message.
Page 20
How to Use To dispense alkaline water Touch the Alkaline Water Button and the pH level is shown on the Display Window. Press the PUSH (Dispensing Button) button with a cup and the Dispensing Cock will protrude to dispense alkaline water with an audible message.
Page 21
To dispense hot water Touch and hold the Hot Water Button for 2 seconds and will be displayed on the Display Window. Also the red lamp is lit on the Hot Water Display. Press the PUSH (Dispensing Button) button with a cup and the Dispensing Cock will protrude to dispense hot water with an audible message.
Page 22
How to Use To dispense purified water Touch the Purified Water Button and will be displayed on the Display Window. Also the blue lamp is lit on the Cold Water Display. Press the PUSH (Dispensing Button) button with a cup and the Dispensing Cock will protrude to dispense purified water with an audible message...
Page 23
Description of Buttons Touch and hold the Clean/Setup Button for 2 seconds and the Button will flicker and the cleaning will start with displayed on the Display Window and an audible message. The cleaning will continue for 300 seconds. When is displayed, the cleaning is completed.
How to Clean Water Tray Steps to Clean Water Tray 2⃞ Pull forward the Water Tray to remove from the Product. 3⃞ 4⃞ Lift up the Cover to remove Wash the Cover and the Tray from the Tray. and wipe off with clean cloth. 5⃞...
Self-diagnosis Error Display Errors detected by Self-diagnosis Function If any of the following error codes is displayed, follow the corresponding instruction to solve the problem. If problems persist please contact the Customer Center (1588-9938). The water feed is either less than 0.5 liter per minute or more than 3.0 liters per minute.
Filter Replacement Cycle Filter Replacement Indication When the filter reaches its life (when the available purification capacity becomes less than 100 liters or 7 days prior to the date of replacement), the corresponding filter number is lit on and the filter replacement indication is displayed on the Display Window.
How to Replace Filter 1⃞ 2⃞ You must shut the Feed Water Touch the Purified Water Button to Corporation Cock first. discharge residual water inside the Product. Repeat until there is no water coming out. 3⃞ 4⃞ Remove the Power Plug from the Insert your fingers in the grooves at socket.
Page 28
How to Replace Filter 7⃞ 8⃞ Hold the filter in the middle of it, Remove the seal from the bottom of new twist anticlockwise (open) and pull filter. upward to remove. Align the bottom of new filter with the filter 9⃞...
Page 29
How to Reset Service Life upon Filter Replacement Press and hold the Mode Button for 5 seconds to enter into the mode setup function. Press the Clean/Setup Button to move to the Filter Setup Mode. is displayed on the Display Window.) Press the Button or the Button,...
Safety Caution Please observe the following instructions for your safety. Failure to observe the following instructions may cause serious physical injuries or damages to the Product. Do not use excessive Do not touch the force to pull the power Power Plug with wet cord to remove the hands.
Page 31
If the Product is Exercise caution moved from one when handling hot place to the other, water. wait about minutes before you plug the Power Plug into the socket. Install the Product For your safely, on solid and level remove the Power ground.
Caution in Use Caution in use of raw water and maintenance of the Product ■ Do not use the Product for any purpose other than intended. ■ Do not place an object on top of the Main Body. ■ Do not block the water outlet. ■...
Caution in Drinking ■ If the Product is not in use for a long period of time (more than a week), remove the Power Plug from the socket. Remove the filters from the Product, remove water from the filters and put them in a vinyl bag and store in upright position. ■...
Page 34
Caution in Drinking Caution in Drinking of pH9.5 Alkaline Water Please observe the following when you drink electrolyzed water. ■ Do not drink alkaline ionized water with medicine. ■ Consult with your physician before starting to drink electrolyzed water. Start with a small amount of water at the pH level close to the neutral level.
Page 35
■ The pH level of alkaline ionized water generated by electrolysis to drink for the improvement of stomach symptoms (chronic diarrhea, indigestion, abnormal fermentation inside the stomach, excessive stomach acid etc) should be pH9.5, but in any case it should not be pH10.0 or higher. ■...
Use of Alkaline Water pH 9.5 alkaline water can improve the symptoms of chronic diarrhea, indigestion, abnormal fermentation in the stomach and excessive stomach acid. If you drink electrolyzed water for the first time, start with a small amount of Level 1 water (pH 8.5), and move onto pH9.0 as you familiarize with alkaline water.
Product Specification 2213 Medical Device License No Manufacturing Permit No 13-1327 Alkaline Ionizer / Instant Cold Alkaline Ionizer KYK IONIZER777 Name of Product/Model KYK Company Limited Manufacturer (#406-410 Sunil Technopia 440 Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do) See the back of the Product Serial No &...
Warranty Certificate Warranty Period Year Month One year from the date of purchase Date of Purchase Address Customer Name Telephone Address Retailer Name Telephone 1. Quality of this product has been controlled and successfully approved by the Korea Food and Drug Administration.
Page 39
KYK Co Ltd is committed to improving your health and happiness.
Page 40
TECHAQUA AG I Grabenstrasse 26 I 8865 Bilten I Schweiz Tel: +41 55 619 62 11 Fax: +41 55 619 62 10 info@techaqua.ch I www.techaqua.ch The head office address / Manufacturing Company : KYK Co.,Ltd #406.407,408 Sun-il technopia, 440 Sangdaewon-Dong, Joongwon-Gu, Sungnam City, Kyunggi-Do, KOREA...
Need help?
Do you have a question about the 777 and is the answer not in the manual?
Questions and answers
Why 2 months bafter switching off kyk Gen 2 for renovation there is no signal on the indicator screen after turning on power