  • Page 1 40016512 NOTICE D’UTILISATION OPERATING INSTRUCTIONS 40016512 GEBRUIKSAANWIJZING BEDIENUNGSANLEITUNG MANUALE DI ISTRUZIONI MANUAL DE INSTRUCCIONES INSTRUKCJA OBSŁUGI...
  • Page 2 5.4 Window open/close detection 5.5 Advanced parameter setting for remote control 6 Heating boost 7 Setting a P1 and/or P2 programme 8 Maintenance and troubleshooting 8.1 Routine maintenance operations 8.2 Troubleshooting 8.3 Replacing batteries 9 Services and guarantee 40016512 11/2017...
  • Page 3: Introduction

    8 years shall not plug in, regulate and clean the appliance or perform user maintenance. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or men- tal capabilities or lack of experience and knowledge if they have 40016512 11/2017...
  • Page 4: Overview Of Your Appliance

    You can set two separate weekly programmes, P1 and P2 with the remote control. Volume 0 IMPORTANT The example shown only concerns a bathtub. For other bathroom fixtures, please consult your installer. IMPORTANT The system must be fitted with an omnipolar circuit- breaker with a minimum contact opening of 3mm. 40016512 11/2017...
  • Page 5 In addition to the arrangement of your installation in the room, its function is also affected by the * See installation manual for value of X temperature setting on the device, and the outdoor temperature. 40016512 11/2017...
  • Page 6 IMPORTANT: The appliance should only be turned on when properly filled with water (failure to N (blue or grey) Neutral comply may invalidate the guarantee). L (brown) Live Pilot wire (black) 40016512 11/2017...
  • Page 7 Then proceed to set the day of the week:   1 Monday 5 Friday 2 Tuesday 6 Saturday boost boost boost 3 Wednesday 7 Sunday 4 Thursday (for example) mode mode mode 40016512 11/2017...
  • Page 8: Warnings

    2) Press again on the LED on the back of the appliance. shedding (pilot Yellow T° override° Error The LED flashes magenta again. You then have one minute to pair your appliance with the wire) remote control. Pairing error / Magenta Pairing underway Appliance not paired 40016512 11/2017...
  • Page 9: Displays

    The standby mode does not affect the functioning of the radiator, and pressing Current time (programme) any key will make the screen light up again. The screen must be on for the pressing of a key to have an effect (e.g. temperature setting, changing a parameter, etc.). 40016512 11/2017...
  • Page 10: Operating Remote Control

    Your appliance operates in eco linked mode by default. Changes of mode ordered by a pilot wire controller (not supplied with your appliance) will not be disabled by this function. The LED on the appliance is on, showing green. mode 40016512 11/2017...
  • Page 11 19°C). If you don't enter a setting, the unlinked Eco temperature will have a default value of 15.5°C. NOTE: You can also set a detailed procedure of these programmes P1 and P2 yourself (see chapter 7). 40016512 11/2017...
  • Page 12 The LED on the appliance will light up with the colour corresponding to the operating mode specified by the control unit (see chapter 4.2). The remote control will cause the icon for the operating mode specified by the control unit to flash. Example: the control unit sends an Eco mode command  40016512 11/2017...
  • Page 13: Calibration Of Temperature Setting

    You measure 19°C in your room, while time for the room temperature to stabilise. the temperature setting on your remote control is 21°C. Press the - key 4 times while in setting 4, until the display shows -2°C (so 21-2=19°C). 40016512 11/2017...
  • Page 14: Advanced Parameter Setting For Remote Control

    Press the output open detection Value 0 (eco temperature unlinked) or 1 (eco temperature Press the After no key has been pressed for one minute, the remote control will automatically temperature linked) quit the advanced parameters and turn off. 40016512 11/2017...
  • Page 15: Heating Boost

    Boost will be triggered in Eco, Comfort, P1 or P2 modes, and will take over the normal operating duration of duration of your appliance. boost boost in steps of boost in boost boost of 15 minutes steps of 15 (total maximum minutes. duration of 120 mode mode minutes). 40016512 11/2017...
  • Page 16 When the set time is reached, mode mode The pro- boost starts. gramme is icon flashes through- activated and out the boost period. on standby. The current boost duration is You can now enable your programmed boost. displayed. mode mode 40016512 11/2017...
  • Page 17: Setting A P1 And/Or P2 Programme

    Note: -)  open settings for boost boost than 2 hours It is mandatory to (120 minutes). programme P2. set the starting time to mode mode enable the automatic boost (see chapter 4). 40016512 11/2017...
  • Page 18 After selecting the operating mode for the final hour of the day, the programming function automatically moves on to the first hour of the next day. mode 40016512 11/2017...
  • Page 19: Routine Maintenance Operations

    An open window detected Turn off the window opening programme. icon flashes) detection function (see chapter 5.5, parameter 1). mode mode boost boost The LED is flashing yellow: Contact your installer. default. 40016512 11/2017...
  • Page 20 Turn on the remote control (e.g.: sending an control and start the pairing process. Eco mode order from the control unit, while the control is set on Comfort). 40016512 11/2017...
  • Page 21: Replacing Batteries

    By disposing of this product correctly, you will help prevent potential negative consequences for the environment and human health. mode Insert the new batteries. Replace the control frame. See chapter 4.1 to reset Standby consumption for the appliance < 0.5W the remote control. 40016512 11/2017...