Antelope CALF-GUARDS User Manual

Electro muscle stimulation

Advertisement

Quick Links

ANTELOPE.CALF-GUARDS
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CALF-GUARDS and is the answer not in the manual?

Questions and answers

Summary of Contents for Antelope CALF-GUARDS

  • Page 1 ANTELOPE.CALF-GUARDS User Manual...
  • Page 3 ANTELOPE .CALF-GUARDS...
  • Page 4 Table of content 1. Introduction ..............1 2. Operating Instructions .............2 3. ANTELOPE – what is included? ........4 4. Programs ................8 5. Troubleshooting Checklist ..........9 6. Wearing the Textile ............11 7. Warnings and Contraindications ........12 8. Further Safety Instructions ..........15 9. Care and Maintenance ..........17 9.1 Battery Life ..............17...
  • Page 5 10. Disposal ................19 11. Guarantee ..............20 12. Packaging...............22 13. Technical Specifications..........24 14. Contact ................25 Wearable Life Science...
  • Page 7: Introduction

    1. Introduction All ANTELOPE products are electro muscle stimulation (EMS) devices. This highly efficient and effective technology must be used responsibly. Before you can start with your training, please read this manual carefully. EMS is a technology, scientifically proven to enhance sports performance.
  • Page 8: Operating Instructions

    3. Plug the other end of the cable into one of the channels of the ANTELOPE.BOOSTER. 4. Switch on the BOOSTER by holding the [+] button for three seconds. 5. Download and open the ANTELOPE.APP and follow the instructions until you reach the program selection screen.
  • Page 9 6. Tap the settings icon and select your BOOSTER in order to connect your device via Bluetooth. 7. Once connected, the BOOSTER will be highlighted in turquoise in the APP and the LED on the BOOSTER will be blue, not blinking. 8.
  • Page 10: Antelope – What Is Included

    3. ANTELOPE – what is included? ANTELOPE .BOOSTER 2CHANNEL.BOOSTER...
  • Page 11 ANTELOPE .APP Welcome Let‘s Go! Unleash your potential with ANTELOPE! START Wearable Life Science...
  • Page 12 ANTELOPE .CALF-GUARDS...
  • Page 13 ANTELOPE .CABLE Wearable Life Science...
  • Page 14: Programs

    7. Relax 4. Strength 8. Show Your Friends The ANTELOPE.APP offers a number of different stimulation programs for various purposes. Each of these programs offers a unique combination of impulse parameters in order to help you maximize your training and/or regeneration effects.
  • Page 15: Troubleshooting Checklist

    Push the cable into the charger until it clicks into place. • Is your unit connected to the garment properly? Check to ensure that the metal cable heads at the end of the cable are attached to the magnetic buttons on the ANTELOPE .TECHWEAR clothing. Wearable Life Science...
  • Page 16 • Are the electrodes placed correctly? Double check if you are wearing the textile properly. Please consult the wearing the Textile section (p. 11) and follow each point as described.
  • Page 17: Wearing The Textile

    6. Wearing the Textile The ANTELOPE.CALF-GUARDS should be worn as shown in the illustrations. The zipper should be on the front. Wearable Life Science...
  • Page 18: Warnings And Contraindications

    The following points should be taken into account. If one or more of these apply to you, ANTELOPE products are not safe for health reasons, and should not be used: • Pacemaker or other electrical implants •...
  • Page 19 Only use ANTELOPE products when you have fully recovered from your previous workout. Follow our workout instructions and do not work out with ANTELOPE too often. ANTELOPE.TECHWEAR must not be used after surgical interven- tions, childbirth, laser surgery (eyes). Please consult a doctor before training with ANTELOPE after such an intervention.
  • Page 20 These problems will not occur if you closely follow our workout instructions. The following points may indicate serious damage to the muscle tissue (rhabdomyolysis). If you find yourself displaying one of these symptoms, please contact a physician: • Brown urine •...
  • Page 21: Further Safety Instructions

    Please follow the safety instructions. Doing otherwise may cause damage to the device, expiry of your guarantee and injury. • Store ANTELOPE products out of the reach of children. • You must not try to replace the battery pack yourself. Opening the BOOSTER yourself may cause damage and will lead to expiry of your guarantee.
  • Page 22 • Do not use ANTELOPE products in wet conditions such as heavy rain or snow, or while bathing, showering or swimming. • Never put the BOOSTER or the cables into the washing machine. Only the textile including the electrodes is washable.
  • Page 23: Care And Maintenance

    9. Care and Maintenance 9.1 Battery Life • In case you do not intend to use the BOOSTER for a longer period of time, please make sure to charge it at least every six months. • Store your BOOSTER in a cool, dry place. Wearable Life Science...
  • Page 24: Washing Instructions

    9.2 Washing Instructions The textile consists of 54% polyamide, 36% polypropylene and 10% elastane. It is washable WITHOUT the BOOSTER. To ensure maximum durability of the textile please follow these instructions: • The textile is washable in delicate mode (cold water/ at 40°C). •...
  • Page 25: Disposal

    10. Disposal Products carrying the ANTELOPE logo must not be disposed of with your normal household waste. Please bring it to a collection point for the recycling of elec- tronic equipment. Wearable Life Science...
  • Page 26: Guarantee

    11. Guarantee We assure a 24 months’ guarantee on all our ANTELOPE products according to §438 BGB. Furthermore, we offer a one- year warranty on electrodes and BOOSTER. Excluded from the warranty are: • Loss/destruction of the product due to normal wear and tear, fire, water damage, theft, vermin or insect infestation.
  • Page 27 • Faulty installation • Wrong maintenance • Service or modifications of the device by made by yourself Wearable Life Science...
  • Page 28: Packaging

    12. Packaging There are a number of technical markings on your unit. These can be explained as follows: By displaying the CE mark the seller confirms that the product complies with all necessary requirements of the EG regulations. Conformity assessment procedures were completed as well, and the procedure identifica- tion number is given with regards to the CE ID.
  • Page 29 Serial Number Batch Number Store in a dry place Warning for critical information (find it in the manual) Wearable Life Science...
  • Page 30: Technical Specifications

    13. Technical Specifications Parameter Description Model ANTELOPE.CALF-GUARDS Temperature (0-35°C), Storage Conditions Humidity (20 – 85%) Temperature (0-35°C), Operating Conditions Humidity (20 – 65%) Measurements (in mm) 105 x 50 x 18 Weight (in grams) Current Max. 100 mA Frequency 1-150 Hz Impulse Width 50-400 µs...
  • Page 31: Contact

    14. Contact Wearable Life Science GmbH Dr. Kurt Schumacher Str. 30 90402 Nuremberg – Germany Email: info@antelope.club Internet: www.antelope.club Telephone: +49 (0) 69 795 888 95 HRB Nuremberg 30554 – Ust DE2950005 Wearable Life Science...

Table of Contents