Download Print this page

Qu-bit Rhythm Manual page 6

4 channel pattern generator

Advertisement

General Functions Overview
1. Clock Input:
External Clock Input
Inserting a clock signal to clock in will externally clock the Rhythm
The number of pulses per quarter note for clock in can be set to 1, 4, 8, or 24
The default setting is 1 Pulse Per Quarter Note (PPQN)
(See Setting Pulses Per Quarter Note (PPQN) for more information)
2. Bank Control Voltage Input:
Unipolar positive control voltage input for bank
Range: 0V – 5V
3. Reset Button:
Button that, when pressed, will move the playback position to the beginning of the pattern
4. Play Button:
Button that, when pressed, will either play or pause the recorded pattern based on the current
state
The tempo display will read PSE when the pattern is paused
Note:
When the play button is pressed, play/pause and mute states are written to non-volatile
memory and will save in between power cycles
5. Pattern Control Voltage Input:
Unipolar positive control voltage input for pattern
Range: 0V – 5V
6. Clock Output:
Tempo output
The number of pulses per quarter note for clock out can be set to 1, 4, 8, or 24
The default setting is 1 Pulse Per Quarter Note (PPQN)
(See Setting Pulses Per Quarter Note (PPQN) for more information)
6

Advertisement

loading