  • Page 1 PSE-308R/316R/324R Power Source Equipment (AC+DC Input, Gigabit PoE Midspan) USER’S MANUAL...
  • Page 2 User’s Manual PSE-308R/316R/324R Contents 1. Introduction................Features....................Package Contents................. 2. Hardware Description............Physical Dimension................Front Panel.................... LED Indicators..................Rear Panel.................... Power On....................Network Application................RJ-45 Remote Control Port..............3. Software Utility Installation..........4. GUI Management..............Display and Illustration................System Login..................
  • Page 3: Introduction

    User’s Manual PSE-308R/316R/324R 1. Introduction PSE-308R/316R/ 324R (Power Sourcing Equipment ), is an AC+DC input, gigabit PoE Midspan which injects power over data-carrying Ethernet cabling. The PSE-308R/316R/324R, support 8, 16 and 24 ports respectively in a 10/100/1000BaseT Ethernet network, over TIA/EIA-568 Category 5/5e/6 cabling. DC operating power, for data terminal units, is fed over data pairs C (4/5) and D (7/8) of the cabling.
  • Page 4: Package Contents

    This Section mainly describes the hardware of the PSE-308R/316R/324R and gives a physical and functional overview. Physical Dimension PSE-308R/316R/324R physical dimension is: 430mm x 290mm x 44mm (Lx W x H) (1U,19” or 23” Rack mountable) Front Panel Figure 2-1. The Front panel of PSE-308R/316R/324R...
  • Page 5: Led Indicators

    User’s Manual PSE-308R/316R/324R The Front Panel of the PSE-308R/316R/324R consists of 8/16/24 x RJ-45 Ethernet ports (data), 8/16/24 x RJ-45 PoE ports (data + power), 8/16/24 x LED port indicators, one LED power indicator and one RJ-45 remote control port (include one LED).
  • Page 6: Rear Panel

    The AC inlet, DC input terminal and 4 Ventilation fan are located at the rear panel of the PSE-316R/324R, (PSE-308R only 2 fans). The device will work with AC in the range 100-240V AC, 50-60Hz. Or work with DC -56V(-42V~-57V).
  • Page 7: Rj-45 Remote Control Port

    Internet Explorer or Mozila, to set the TCP/IP parameter. Before you use the web interface to set the PoE TCP/IP, verify that PSE-308R/316R/324R is properly installed on your network and PC on the network can access PoE via the web-browser.
  • Page 8 9. Key in ID (user name) and password to enter PoE TCP/IP parameter setting. Default ID and password is admin and system. 10. PSE-308R/316R/324R TCP/IP parameter has 4 pages interface (administrator setting, TCP Mode, UDP Mode and UART). You must change the administrator & TCP...
  • Page 9 User’s Manual PSE-308R/316R/324R 11. Administrator setting: you can assign nickname, IP setting, user name, password and view system information. Nickname: You can assign a name to the device. IP Address: You must assign the IP address reserved by your network. The default IP is 192.168.1.10.
  • Page 10 User’s Manual PSE-308R/316R/324R 12. TCP Mode: You can update the TCP control parameter here. Telnet Server/Client: Set to Server for PoE management operation. Port Number: You can assign port number for TCP/IP operation. The default Port Number is 23. Remote Server IP Address: Unused.
  • Page 11 User’s Manual PSE-308R/316R/324R 13. UDP Mode: This mode is not used in the PoE application.
  • Page 12 Stop Bit: Set to 1 stop bit for PoE operation. Hardware Flow Control: Set to none flow control for PoE operation. When you have finished the set up, click on Update to update your setting. PS: The PSE-308R/316R/324R don’t used in the Telnet terminal.
  • Page 13 User’s Manual PSE-308R/316R/324R 15. When you have configured your set up, you must reset the device to take effect.
  • Page 14: Software Utility Installation

    User’s Manual PSE-308R/316R/324R 3. Software Utility Installation Before you start to remote configure the PD, please install the software utility. Through the software utility, you can easily to control the PD which connects with PoE and view the PD parameter information. The software utility provides GUI interface and it is easy to install.
  • Page 15: Gui Management

    User’s Manual PSE-308R/316R/324R 4. GUI Management Display and Illustration Connect the PSE with a PC through the remote control port. Then, run the software utility (Netclient). You will see the main utility interface below. Tools bar PSE station selection & alarm indicator Display PSE station PSE station name&IP setting...
  • Page 16: System Login

    User’s Manual PSE-308R/316R/324R System Login Run the management software, the system will show the diagram below. Now enter the password, first enter the default setting which is “0000”...
  • Page 17: Modify Password

    User’s Manual PSE-308R/316R/324R Modify Password Click “File” and select “Modify PSW”, you can modify the password, the system permits 3 sets of password.
  • Page 18: Edit Station Tcp/Ip

    User’s Manual PSE-308R/316R/324R Edit Station TCP/IP Click “Setting”, and select “LAN Setting”, or click “LAN Setting” icon, the screen will enter IP Setting window.
  • Page 19 User’s Manual PSE-308R/316R/324R In the IP Setting display window, you can edit the station name, TCP/IP address and port number. Click the Edit icon to modify this parameter. In the Edit window, click the View icon to display TCP/IP parameter.
  • Page 20: Edit Remote Poe Ip

    User’s Manual PSE-308R/316R/324R Edit Remote PoE IP In the IP Setting display window, you can use “PoE IP Setting” icon to start the web-browser. To modify the remote PoE TCP/IP parameter, please reference RJ-45 Remote Control Port of section 2 Hardware Description (page 7).
  • Page 21: Gui Connect All

    User’s Manual PSE-308R/316R/324R GUI Connect All In the main page window, click “GUI” and select “Connect All” command or click “connect all” icon, if the Station Selection window shows the name icon and displays power status(green or red) light, it means that the PSE connection is correct. You can...
  • Page 22 User’s Manual PSE-308R/316R/324R GUI connect example: In the Station Selection window, the LED indicates real time connection of PSE. Green-----this connection and PSE power are normal. Red--------this connection is OK but PSE power is not correct. Orange---this connection is not working..
  • Page 23: Single Station Connect/Disconnect

    User’s Manual PSE-308R/316R/324R Single Station Connect/Disconnect In the IP Setting window, you can click Connect/Disconnect icon to enable/disable single station connection, the LED indicates real time status of TCP/IP. Green-----TCP/IP connection is OK. Red--------TCP/IP connection is not working. Gray-------TCP/IP parameter is not setting.
  • Page 24: Station And Status Window Select

    User’s Manual PSE-308R/316R/324R Station and Status Window Select The PSE management software can monitor 24 PSE simultaneously. In the GUI Disconnect all mode, only the IP Setting display window can be used to set the TCP/IP parameter. In the GUI Connector mode, there two display windows can choose - Port Status &...
  • Page 25: Edit Port Name

    User’s Manual PSE-308R/316R/324R Edit Port Name Click “Setting”, and select “PoE Name” or click the “PoE Name” icon. The screen will enter IP Setting window. You can assign a name to the PSE port individually. In the “Module Select” window, select the suitable port that you require.
  • Page 26: Configuration

    User’s Manual PSE-308R/316R/324R Configuration In the main page window, click “Config”, and select “Setup”, the screen will show the system control panel as below. Set icon: Apply the operation mode to PSE system. Set Enable/Set Disable icon: Change the Board Status window to set enable/disable.
  • Page 27: Factory Setting

    User’s Manual PSE-308R/316R/324R Factory Setting Click “Config”, and select “Factory” or click the “Factory” icon. The screen will show the factory setting control panel as below: then click “Y” for the Factory Setting.
  • Page 28 User’s Manual PSE-308R/316R/324R Factory setting as below: Operation Mode → Auto (Auto, Force & Shutdown) AC Disconnect → On (On & Off) DC Disconnect → Off (On & Off)
  • Page 29: Board Status

    User’s Manual PSE-308R/316R/324R Board Status Click “Config”, and select “GetBoardStatus”, or click “Board STATUS” icon, the screen will show current status of each port.
  • Page 30: Port Status

    User’s Manual PSE-308R/316R/324R Port Status In the main page window, click “StatusDisp”, and select “PortStatus”, or click the “PORT STATUS” icon, the screen will show current status of each port and current power supply status of each module. If all power modules are working normally, the “Sys. Power” will show a green light, if...
  • Page 31: Gui Version

    User’s Manual PSE-308R/316R/324R GUI Version Click “StatusDisp”, and select “GUI Version”, the screen will show the version of the EMS utility...
  • Page 32: Gui Disconnect All

    User’s Manual PSE-308R/316R/324R GUI Disconnect All Click the “GUI”, and select “Disconnect All”, or click the “GUI disconnect all” icon to disconnect the communication between GUI and PSE.
  • Page 33: File Open And Save

    User’s Manual PSE-308R/316R/324R File Open and Save You may click “File” and select “Open”, or click the ”Open file” icon, to open the previous setting file. Click “Save”, or “Save file” icon, to save the current setting.
  • Page 34: Technical Specification

    User’s Manual PSE-308R/316R/324R 5. Technical Specification PARAMETER PSE-308R PSE-316R PSE-324R Data Ports PoE Ports Pass through Data Rates 10/100/1000Mbps Console Port 1× RJ45 console interface for management Per port DC 48V@350mA 16.8W(Maximum) Output power Pair4/5(+),Pair7/8(-) Power consumption 134W 268W 403W...