Safety Notes --- Important Safety Notes Thank You for Choosing Our Weather-proof Vehicle PTZ Camera! When you open the box: 1. Check that the packing and the contents are not visibly damaged. Contact the retailer immediately if any parts are either missing or damaged. 2.
Page 5
Safety Notes --- Important Table of Contents SAFETY NOTES ..................3 TABLE OF CONTENTS ................5 ABOUT THE PRODUCT ................1 ......................1 EATURES .....................1 ACKING ......................2 UNCTIONS ....................3 ECHNICAL PREPARATION ....................4 ..................5 IP SWITCH SETTINGS ..................7 NITIAL POWER ON TEST ..............8 HECK NSTALLATION NVIRONMENT ....................8 ACKAGE...
Page 7
Safety Notes --- Important The following important notes must be followed carefully to run the camera and respective accessories in total safety. The camera and relative accessories are called video system in this section. Before installing the camera, please read this manual carefully; when installing please follow instructions of installation indicated in this manual.
Page 9
About The Product About The Product The network rugged PTZ camera is designed for mobile video surveillance, marine, security and etc, it consists of a network PTZ camera, powerful lighting system, and high precision mechanical part. Features 1/2.8 inch Progressive Scan CMOS, 20x optical zoom; ...
Page 10
About The Product Functions Soft Address Camera address can be changed via calling specific presets. Baud Rate and Protocol Self-adaptive Camera can detect Pelco D and Pelco P protocols and 2400bps, 4800bps, 9600bps and 19200bps baud rate automatically. Set Camera Address, Baud Rate and Protocol Every camera needs to have its own address, baud rate and protocol, the camera only responses to the commands sent with the same settings, please refer to DIP settings for more information about setting address, baud rate and protocol.
About The Product Focus control System defaults Auto Focus mode, that is, the lens and camera will automatically adjust the focus to get the best image. Focus can also be controlled manually from the controller if required. Press Focus Near or Focus Far key to manually focus.
Page 12
About The Product Auto Cruise The preset position is programmed to be recalled in sequence. Auto Scan Make the camera scan continuously starting from current position. Random Scan Make the camera scan from current position, pause at specific positions. Frame Scan Make the camera scan between two set positions.
About The Product Technical Data Camera Image Sensor 1/2.8 inch Progressive Scan CMOS, 2.13megapixel Effective Pixel 1920(H) x 1080(V) Video Format 1080P/30, 1080P/25, 720P/60, 720P/50, 720P/30, 720P/25 SD video NTSC / PAL (optional) Min. Illumination Color: 0.0013Lux; B/W: 0.0008Lux White Balance Auto Focus Auto/Manual...
Preparation OSD Language English Comm. Interface RS-485 Address 0-255 SD Video CVBS 1.0V[p-p] / 75Ω, PAL or NTSC Output(Optional) Network 10M/100M Interface Protocol PELCO-P/PELCO-D(self-adaptive) Baud Rate 2400/4800/9600/19200bps(self-adaptive) Power Supply DC10.8-28V Power MIN:9W Consumption Max:20W Work -30℃~+65℃ Temperature IP Protection IP66 Other Protection Standard: Φ136(mm)×185(mm) Dimension...
About The Product Dip switch settings Before operating the camera, set the camera address, protocol, baud rate. The switches to configure the address settings are located on back panel of the camera. Pic. 1 show the switches on back panel. Default setting is address 1, baud rate 9600bps, protocol Pelco D. Pic.
Page 16
Preparation Camera Address ….. ….. ….. ….. ….. ….. ….. ….. ….. [Note] The camera shall be rebooted after the switches are programmed.
Operation Settings Initial power on test To ensure the camera works well after installation, please power on it for an initial test with the following steps: Connect the camera with correct power supply; Connect control cable, video cable; ...
Installation Please refer to the following code to check the failures: Failure of pan initialization FAIL TILT FAIL Failure of tilt initialization CAM FAIL Failure of block camera initialization P/T FAIL Failure of pan and tilt initializations T/Z FAIL Failure of tilt and block camera initializations Failure of pan, tilt and block camera P/T/Z FAIL initializations...
Installation Dimensions There are three installation methods: fixed, wall and magnetic mount. Fixed Installation Pic. 1 Dimensions: Fixed Installation Wall Installation Pic. 3 Dimensions: Wall Mount Installation...
Installation Installation Fixed Mounts Take the PTZ camera out of packing and fix it to the target place as per the installation dimensions with correct screws. Wall Mounts: According to diameter and position of the 4 installation holes (As shown below) on the bracket, drill 4 holes on the wall and fix the bracket onto the wall by using 4 screws which should be prepared by yourself.
Menu Settings 3) Below picture shows the final effect after installed. Connections Connect the cable with the right pins as per following pictures. Pin definition of the 10-pin aviation plug Pin Number Definition Pin Number Definition 485+ Power- 485- Power+ Audio Output Audio- Audio Input...
Installation Menu Settings Menu Configuration <VIDEO> FORMAT 1080p25, 1080p30, 720P50,720P60,720p25, 720p30 Refer to WIDE DYNAMIC ON, OFF, AUTO Page 15 1, 2, 3, 4, 5, OFF FOCUS MANUAL , AUTO FREEZE ON, OFF DIGI ZOOM ON, OFF EXPOSURE… <PAN TILT> LIGHT ON, OFF DAY/NIGHT...
Page 24
Menu Settings <SYSTEM> ADDRESS 0~255 Refer to page PROTOCOL PELCO-D/P BAUD RATE 9600 VIDEO FORMAT 1080p30 MOUNT MODE STAND DISPLAY INFO ON, OFF SOFTWARE VER V1.0.0 <REBOOT> Refer to page 22 < RESTORE FACTORY DEFAULTS> Refer to page 23...
Menu Settings Menu Settings Menu Explanation Main Menu Settings Call preset 95 to enter menu. ❶ <MENU> VIDEO PAN TILT ❷ SYSTEM REBOOT RESTORE FACTORY DEFAULTS ❶ Men It displays currently selected menu options. ❷ Menu Operations It displays options under current menu. Navigate up or down to choose option, the mark ...
Page 26
Menu Settings Options Available Values Explanation If HD video format is set at 1080p30 or 720p30 or 720P60, 1080p25, 1080p30, relative SD video output is NTSC. FORMAT 720p25, 720p30 If HD video format is set at 1080p25 or 720p25 or 720p50, relative SD video output is PAL.
Menu Settings Menu EXPOSURE Settings <EXPOSURE> MODE FULL AUTO SLOW SHT.LIMIT Settings Options Available Values Explanation FULL AUTO MANUAL MODE Switch among exposure modes. SHUTTER PRI IRIS PRI) FULL AUTO: Gain, Shutter Speed and Iris value are adjusted automatically accordingly to working environment.
Menu Settings IRIS PRI: Gain and shutter speed value are adjusted automatically according to working environment; Iris value is adjustable manually. IRIS Values: F14, F11, F9.6, F8, F6.8, F5.6, F4.8, F4, F3.4, F2.8, F2.4, F2, F1.6, CLOSE。 PAN TILT PAN/TILT is used to change pan/tilt/zoom value; available options are shown as below: <PAN TILT>...
Menu Settings Menu PAN/TILT Set camera’s Pan / Tilt speeds. 1, 2, 3 Settings SPEED AUTO FLIP ON, OFF Set auto flip On or Off. When camera is kept idle for a PARK… specific period, it will performance Settings the park action. PRESET <PRESET>...
Menu Settings <PRESET EDIT> CLICK IRIS OPEN CONFIRM CLICK IRIS CLOSE CANCEL DELETE Operations Under <PRESET> menu, navigate up or down to choose <DELETE>,use Right control arrow to get into <DELETE> menu, choose <YES>, press Iris Open to delete preset or Iris Close to cancel operation.
Menu Settings Menu FRAME SCAN Settings <FRAME SCAN> -INTERVAL/S EDIT DELETE Settings Options Available Values Explanation INTERVAL/S 4~13S Set interval of frame scan EDIT YES, NO Edit presets of current frame scan DELETE YES, NO Delete current frame scan EDIT Operations Under <FRAME SCAN>...
Menu Settings <SYSTEM> ADDRESS PROTOCOL PELCO-D/P BAUD RATE 9600 FORMAT 1080P30 MOUNT MODE STAND DISPLAY INFO SOFTWARE VER V1.0.0 Options Available Values Explanations Suggested call presets change camera’s address, new ADDRESS 0~255 address will take into effect after camera is rebooted. Displays current protocol, camera supports Pelco P/D protocols, and PROTOCOL...
Menu Settings Menu Settings <REBOOT> CONFIRM REBOOT CLICK IRIS OPEN CANCEL REBOOT CLICK IRIS CLOSE Settings RESTORE FACTORY DEFAULTS Under main menu, navigate up or down to choose < RESTORE FACTORY DEFAULTS>, press Iris Open to get into the menu shown as below: <...
Trouble Shooting Special Control Commands The camera can be programmed and operated using various quick control commands listed as below. Preset Number Function Default Value Manual switch between color mode and mono mode Auto switch between color mode (with IR off) and mono √...
Operation Menu Operation Settings As the baud rate and protocol are self-adaptive, the PTZ cameras may not response for seconds on power up. It is recognizing the commands and adapting the setting. Settings Auto Mode (For IR Version Only): Default IR mode is auto. Auto mode can also be activated via calling preset 22. At this mode, the commands of preset 30, 31 are disabled.
Trouble Shooting Pic. 7: Image Freeze Soft Address The camera address can be changed via presets 62 and 63. The new address will take effect after the camera is rebooted.
Operation Menu Trouble Shooting Settings Problems Possible Causes Solutions Power supply failure Replace power supply No action when powered Wrong connection of the Settings Check & reconnect the cables power Mechanical failure Repair Abnormal self-test with Camera inclined Reinstall the camera motor noise Inadequate power supply Replace the power supply...