  • Page 1 BATTERY TESTER INSTRUCTION MANUAL...
  • Page 2 Index Page 1. Introduction......... 2. Safety notes........3. Features..........4. Specifications........5. Instrument layout......... 6. Measurement........7. Maintenance........
  • Page 3: Introduction

    1. Introduction NOTE This meter has been designed and tested according to CE safety requirements for electronic measuring apparatus, IEC / EN 61010-1 and other safety standards. Follow all warnings to ensure safe operation. WARNING READ "SAFETY NOTES" (NEXT PAGE) BEFORE USING THE METER.
  • Page 4: Safety Notes

    2. Safety notes ● Read the following safety information carefully before attempting to operate or service the meter. ● Use the meter only as specified in this manual. Otherwise, the protection provided by the meter may be impaired. ● Rated environmental conditions: (1) Indoor Use.
  • Page 5: Features

    3. Features The battery impedance tester can measure battery impedance and DC voltage at on line. Impedance measure signal used 1kHz AC frequence. Test lead used 4-wire measurement method can reduce contact resister. ● 2000-count LCD ● DC Voltage measurement. ●...
  • Page 6: Specifications

    4. Specifications (All at 23°C±5°C, ≤ 80%R.H) ● DC Voltage Range Resolution Accuracy ± (1% rdg+1dgt) 10mV ± (1% rdg+1dgt) 100V 100mV ± (1% rdg+1dgt) ● Impedance Range Resolution Accuracy 200mΩ 0.1 mΩ ± (3% rdg+3dgt) 2000mΩ 1mΩ ± (3% rdg+3dgt) 20Ω...
  • Page 7: Instrument Layout

    5. Instrument layout (1) Function Switch (2) LCD Display (3) Sense "+" Terminal (4) Source "+" Terminal (5) Sense "-" Terminal (6) Source "-" Terminal (7) HOLD Button...
  • Page 8 (1) Function selection rotary switch The rotary switch selects the function. (2) LCD Display 1999 count LCD with LOW BATTERY indication. (3) Sense "+" Terminal This is the positive input terminal for voltage / ohm measurement. Use the RED test lead to connect.
  • Page 9: Measurement

    7. Measurement ● Battery voltage measurement (1) Insert the RED test lead to Sense (+) and Source (+) terminal and the BLACK test lead to Sense (-) and Source (-) terminal. (2) Rotate function switch to DCV range function. (3) Refer to battery voltage rate and select test range.
  • Page 10: Maintenance

    8. Maintenance ● Battery replacement When low battery warning appears, change new batteries as follows: (1) Disconnect the test leads from the instrument and turn off the power. (2) Unscrew the case and replace with new battery. (3) Close the case and lock the screw. Warning! To avoid electrical shock or damage to the meter, do not get water inside the case.
  • Page 11 ● Cleaning and storage Periodically wipe the case with a damp cloth and detergent. Do not use abrasives or solvents. If the meter is not used for over 60 days, remove the battery for storage. CAT IV - For measurements performed at the source of the low voltage installations.
  • Page 12 -10-...