Do you have a question about the AHPTZ122IRA and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Comelit AHPTZ122IRA
Page 1
DOME IR PTZ AHD ART. AHPTZ122IRA Please read this manual thoroughly before use and keep it for future reference...
Page 2
WARNINGS AND CAUTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT. CAUTION EXPLANATION OF GRAPHICAL SYMBOLS The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user the presence of non-insulated “dangerous voltage”...
Page 3
PRECAUTIONS: Persons without technical qualifications should not attempt to operate this dome device before reading this manual thoroughly. Remove any power to the dome before attempting any operations or adjustments inside the dome cover to avoid potential damage to the mechanism. ...
Page 4
IMPORTANT SAFEGUARDS 1. Read these instructions before attempting installation or operation of dome device. 2. Keep these instructions for future reference. 3. Heed all warnings and adhere to electrical specifications Follow all instructions. 4. Clean only with non abrasive dry cotton cloth, lint free and approved acrylic cleaners. 5.
1.2 Specification Horizontal Rotation Speed 0.02-480°/s Tilt Rotation Speed 0.02-160°/s Horizontal Rotation Range 360° Tilt Rotation Range 93° Auto Flip Horizontal 180°, Vertical 93° Ratio Speed Support Preset Points Go to Preset Speed 1-64 grades available 360° Scan 1-64 grades setting available A-B Scan User programmable A-B Scan Speed...
1.3 Function Description Multilanguage OSD Menu The language display on screen menu, the available language is English etc.. User can set the function or parameter, or check the related information through the OSD. IR Detection Time Time duration switching from Color to B/W or B/W to Color. It can be set through OSD Focus The auto focus enables the camera to focus automatically to maintain clear image.
Page 10
Day/Night Switch With auto day/night switch function, when the illumination is low the picture will auto switch from day to night mode and when the illumination is high enough the picture will auto switch from night to day mode Ratio Speed Intelligent pan and tilt speed is variable depend on the zoom factor.
2 Installation 2.1 RS485 control The dome support RS-485 communication signal. 2.1.1 AC24V power cable transmission distance and cable requirement In general, the power cable has resistance, there are internal losses when transmitting the voltage, the longer of the cable used, the smaller the wire diameter, the worse loss will suffer.
2.3 Installation of Brackets. 2.3.1 Wall Mounted Fig 1 Installation conditions: Wall mounted dome can be used in the hard wall structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment. The wall can bear at least 4 times the weight of the dome.
2.3.2 Corner Mounted Fig 4 Installation conditions: Corner mounted dome can be used in the hard wall structure with an angle of 90° whose thickness should be enough to install expansion bolt in indoor and outdoor environment. The wall can bear at least 4 times the weight of the dome. Install corner mounted attachment and wall hanging bracket: a.
Fig 6 c. As shown in Fig7, fix the wall hanging bracket with all cables power through it on the corner mounted attachment. Fig 7 2.2.3 Pole Mounted Fig 8 Installation conditions: Pole mounted dome can be used in the hard pole structure in indoor and outdoor environment whose diameter should match the installation size of stainless hose clamps.
a. As shown in Fig 9, use the stainless hose clamps to fix the pole mounted attachment with all cable through it on the pole structure. Fig 9 b. As shown in Fig 10, fix the wall hanging bracket with all cables through it on the pole mounted attachment.
Page 17
should be enough to install expansion bolt in indoor and outdoor environment. The ceiling can bear at least 4 times the weight of the dome. Install the base of ceiling and boom: a. As shown in Fig 12, with the installation holes in the base of ceiling as pattern, draw punched locations in the ceiling and punch to install M6 expansion bolt.
2.4 Connection Connection of RS485 Before connecting, please turn off the power and read carefully the instructions of all connected devices. ( If the camera and the DVR support coaxial control, please ignore this step). Fig 24 3. Function Instruction 3.1 Power Up Action <SYSTEM>...
3.2 Basic Function Dome Running Control joystick or up, down, left and right key in the keyboard. Zoom Press ZOOM- button to make the lens farther and magnify the scene. Press ZOOM+ button to make the lens closer and magnify the scene. Focus Press FOCUS- button , close shot will become clearer while long shot will become fuzzy.
Twice 137 Switch to AHD Twice 138 Switch to TVI Twice 139 Switch to CVI Twice 140 Switch to CVBS Twice 115 Switch to NTSC Twice 116 Switch to PAL Remark : Some special functions probably can’t be effective because of the limit of protocol when the dome controlled by different devices.
4.2 System Information <SYSTEM> <MAIN MENU> <SYSTEM> PROTOCOL PELCO D-P <DOME> DOME ID <CAMERA> COMM 2400.N.8.1 41.8 ℃ <DISPLAY> TEMPERATURE <LANGUAGE> VERSION V863R15122109 <TIMING TASK> EXIT <ALARM> <RESET> EXIT When enter the OSD, it display SYSTEM, you will see: MFG : Max 15 characters displayed on the screen. PROTOCOL : Display the protocol of the dome DOME ID : Display the dome address COMM : Baud rate.
4.3.1 Communication <COMM> <COMM RESET> DEVICE ID 125295 RESET TO DIAL THE CODE CHECK ID 125288 TARGET ID SOFT PROTOCOL AUTO BAUD RATE 2400 <COMM RESET> SAVE EXIT F ig4.3.1.1 Fig.4.3.1.2 DEVICE ID : It is sole and auto generated by system. CHECK ID : To change the TARGET ID, please input the CHECK ID exactly same as the DEVICE ID displays on the screen.
ILLUMINATION ON : Illumination on is 1 to15 grade selectable and default is 3. On the auto IR working mode, if the illumination on level is less than the ambient light, the picture will change to color, the IR illumination will turn off automatically. If the illumination on level is more than the ambient light, the picture will change to black , the IR illumination will turn on automatically.
Fig4.3.4.1 Fig 4.3.4.2 PRESET A : On A-B scan, A point can be any point PRESET B : On A-B scan, B point can be any preset. SCAN SPEED : A-B scan speed is 1 to 64 grade selectable. DWELL TIME : Dwell time between A to B is 2s to 60s selectable. RUNNING : Running the A-B scan.
4.3.7 Park Action <PARK ACTION> <PARK ACTION> PARK MODE PARK TIME <SETTING> PRESET 1: SAVE CALL PRESET 2: BACK DELETE EXIT 4.3.7.1 4.3.7.2 PARK MODE : Park mode includes OFF, Park action, A-B scan, Pan scan, guard tour 01,pattern 1. When park mode is OFF status, the dome doesn’t run park mode.
Remark : The mask size is better than double the target size. If needing to modify mask NO.02, set it again. If needing to stop it, set mask to OFF status. If the module doesn’t support privacy mask, the screen will display the interface as Fig. 4.3.8.3.
BLC : BLC is ON and OFF selectable FREEZE : Video freeze is ON and OFF selectable Remark : Only if those functions are available on the present module, the user can use them. 4.5 Display <DISPLAY> SYSTEM P AND T ZOOM ACTION DOME ID...
4.9 Reset <RESET> <DOME RESTART> <DOME RESTART> CONFIRM: SAVE DATA, <SYS DATA> DOME RESTART <CAM DATA> <PRESET> <SYS DATA> <CAM DATA> CONFIRM: FACTORY DEFAULT CONFIRM: FACTORY DEFAULT CONFIRM : Delete the presets information saved by the dome. 5. Auto Temperature Control This product has built-in fan and heater, which accordingly cool or heat through temperature sensitive circuit inside the dome.
Appendix Ⅰ Anti-lightning, Anti-surge This product is extremely air discharge and lightning protection with TVS tube technology, which can effectively prevent the transient lightning below voltage 6000V, surge and damages caused by other types of pulse signals. However, necessary protective measures should be made in the premise of ensuring electrical safety for outdoor installation according to the actual situation : ...
Appendix Ⅱ Clean Transparent Cover In order to assure a clear image of dome, the under cover of dome should be cleaned regularly. Be careful when cleaning and hold the outer ring of under cover by hands to avoid directly touching with it.
Appendix Ⅳ Exception Handling Issue Possible Reason Solution After power Cable harness is improperly Verify that the orientation of the is applied, connected connector input there is no motion Input power voltage is too low Verify the voltage of the input power (self-test) and no video Power supply is not work...
Copyright Statement This copyright is merely belong to the manufacturer. Without permission, please don’t plagiarize or copy the contents of this book in any form or by any means. The company follows the policy of continuous development. Therefore, the company reserves the right to modify or improve the products described in this manual without notice.
Need help?
Do you have a question about the AHPTZ122IRA and is the answer not in the manual?
Questions and answers