Download Print this page

Yusing YFL03E-230V-10W-PIR User Manual page 2

Led infrared induction floodlight

Advertisement

Delay Settings
Delay time : 10sec~10min ajustable
Knob adjustable angle of 270 °
When the light is on , product will reset delay time
and keep the light on when detected new signal
When the light just off, need a second time to
recover the induction
Induction illumination settings
Induced enviroment illuminance range 10~2000LUX
Knob adjustable angle of 270 °
Induction Distance Settings
Induction distance is 5~8 meters
Knob adjustable angle of 270 °
Diagram Showing
Installation
Find a suitable location to install this product.prepare the mains wiring.
Use the mounting bracket to mark the hole centres for fixing.
Drill holes suitable to accept wall plugs.Insert wall plugs.
Ensure mounting bracket.
Terminate wiring.Pay particular attention to any markings for Repalce all covers.
Fit the floodlight to the mounting bracket with the screws,
Check seals,gaskets and cable gland operation before testing the luminaire.
Turn on power supply and test luminaire.
Wire connection guide
The brown wire is connected with the L wire of city electricity.
The blue one is connected with the N wire of city electricity.
The green/yellow one is connected with the earth wire.
Power Cord type:H05RN-F 3 x 1.0mm2
Brown(L)
Direct Chassis(E)
Blue (N)
TIME
LUX
SENS
Live:Brown or Red
Earth:Green/Yellow
Neutral:Blue or Black
Important Infomation
It is recommend that luminaires installed and fitted by a qualified
electrican ensuring the installation complies to the current building
regulations.these products are designed for connection
to a 100-240V~50/60Hz supply.
Any broken or damaged parts should be replaced as soon as possible.
YUSING will not accept responsibility for any claims arising from a poor
installation.
Impotant User Advice
This Product is Class I and must be Earthed.
Always switch off mains supply before fitting.
Replace any broken or damaged glass as soon as possible.
Ensure all seals are intact and operational after fitting or maintenance.
Do not touch the lamp in use or just after use as there is a risk of being burnt.
Do not cover it with paper or cloth.
Take off from flammable materials.
Do not wash the lamp.
Do not use the lamp where the ambient temperature is over 45°C.
Keeping your eyes with a security distance,the light could cause damage.
This product has no user serviceable parts.
Clean with a damp cloth and dry with a lint free cloth or kitchen towel.
To move or placed, The product must face up To avoid damage to the sensor
Fault and solution method
Low sensitivity induction or doesn't work
Please check there is no barrier in front of the lamp
Please check the induction signal source is in the sensing range
Please check the installation height in the valid range
Please check the working illumination sensor setting is consistent with the
environmental illumination.
When the environment temperature is close to body temperature, detection
sensitivity will be decreased obviously, sometimes resulting in short-term failure
Can off load
Please check whether there is a continuous induction signals in the sensing
range
Please check whether the longest time delay setting
Please check The installation environment whether have infrared interference
Please check whether there is a moving object near the lamp