Böning AHD 1200 Operation Manual

Böning AHD 1200 Operation Manual

Embedded pc

Advertisement

Inhaltsverzeichnis
AHD 1200
Embedded PC
Operation Manual
Read this manual before beginning any work!
Dok-ID: PaJ-1045 V1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AHD 1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Böning AHD 1200

  • Page 1 Inhaltsverzeichnis AHD 1200 Embedded PC Operation Manual Read this manual before beginning any work! Dok-ID: PaJ-1045 V1...
  • Page 2 © Böning Automationstechnologie GmbH & Co. KG Am Steenöver 4 D-27777 Ganderkesee Tel.: +49 (0) 4221 9475-0 Fax: +49 (0) 4221 9475-21 /-22 E-Mail: info@boening.com Internet: www.boening.com...
  • Page 3 Mechanical Structure ........... 13 Device Electronics ............14 Interfaces ..............14 Electronic Data Processing .......... 15 Configuration..............16 Technical Information ............17 Technical Data AHD 1200 ........... 17 Name Plate ..............18 Dimensions ..............19 4.3.1 Device Dimensions ........19 4.3.2 Drill Holes .............
  • Page 4 AHD 1200 Embedded PC Inhaltsverzeichnis 6.2.3 Cooling ............30 6.2.4 Updating the Firmware .........31 6.2.5 Transferring the Configuration ......31 Initial Startup ..............32 Operation ................33 Power On ..............33 Selecting the Video Source ..........33 Power Off ..............34 Maintenance ................35 Errors ..................36 Safety ................36 Error Correction ............37...
  • Page 5: General Information

    AHD 1200 Embedded PC General Information Change History for Operation Manual AHD 1200 Date Version Reason for Change Page Author 11/19/2012 AHD_1200_DOK_en_V1_20121119 New Creation Entire Patzke, Jens Document (PaJ)
  • Page 6: General Information

    AHD 1200 Embedded PC General Information 1 General Information 1.1 About this Manual Read this operation manual carefully before beginning any work! It is part of the product and must be kept in the prod- uct’s immediate vicinity, so that it is always available to the personnel.
  • Page 7: Limitation Of Liability

    AHD 1200 Embedded PC General Information CAUTION! … indicates a potentially hazardous situation that can result in minor or light injury, if not avoided. CAUTION! … indicates a potentially hazardous situation that can result in equipment damage, if not avoided.
  • Page 8: Copyright

    AHD 1200 Embedded PC General Information 1.4 Copyright This operation manual is a confidential document. It is intended solely for those persons working with the product. It is not permit- ted to hand this manual over to third parties without the manufac- turer’s prior written permission.
  • Page 9: Safety

    AHD 1200 Embedded PC Safety 2 Safety This chapter provides an overview of all important safety aspects for optimal protection of the personnel as well as safe and error- free operation. Noncompliance with the handling and safety instructions listed in this manual can cause significant hazards.
  • Page 10: Personnel Requirements

    AHD 1200 Embedded PC Safety 2.2 Personnel Requirements 2.2.1 Qualifications WARNING! Risk of injury from insufficient qualifications! Improper use can lead to significant Personnel in- jury and equipment damage. Therefore: – Only allow qualified personnel to perform any work. This manual lists the following qualifications for various areas of activity.
  • Page 11: Unauthorized Persons

    – Interrupt all work as long as unauthorized per- sons remain in the work area. 2.3 Intended Use AHD 1200 has been designed and constructed exclusively for the purpose described in this manual. AHD 1200 adapts various device types by external manufactur- ers to the Böning ship alarm, monitoring, and control system.
  • Page 12 AHD 1200 Embedded PC Safety WARNING! Danger from improper operation of the product! Product failure or malfunctions can lead to Person- nel injury or equipment damage in the overall sys- tem. Therefore: – Although the product itself is not especially dan- gerous, the effects of failures or malfunctions on the overall system must be considered.
  • Page 13: Structure And Function

    Structure and Function 3 Structure and Function 3.1 General Function The Embedded PC AHD 1200 is integrated into the vessel’s moni- toring and control system and adapts device types by external manufacturers into a Böning ship alarm, monitoring, and control system.
  • Page 14: Device Electronics

    AHD 1200 Embedded PC Structure and Function 3.3 Device Electronics The Embedded PC AHD 1200’s central unit is a 1.6 GH dual core microprocessor that reads all incoming data and requests in the supported protocols, providing all required information via a redun- dant CAN bus in the ship system.
  • Page 15: Electronic Data Processing

    The five relay outputs are primarily used for switching external alarm indicators. 3.5 Electronic Data Processing The Embedded PC AHD 1200 reads the ship data via the vessel’s CAN bus, processes them, and makes them available via the CAN bus to other devices, such as displays.
  • Page 16: Configuration

    AHD 1200 Embedded PC Structure and Function special functions to use the AHD 1200 for monitoring and control- ling ships. Furthermore, control devices (receiver), interfaces, and relay out- puts, are configured in the configuration. TIP! More information for configuring the AHD 1200 with...
  • Page 17: Technical Information

    AHD 1200 Embedded PC Technical Information 4 Technical Information 4.1 Technical Data AHD 1200 Description Value/Unit/Type General Data Dimensions, W x H x D 400 x 320 x 112mm Panel Cutout, W x H 354 x 292mm Req. Installation Depth min.
  • Page 18: Name Plate

    In Progress RMRS, RINA, CRS 4.2 Name Plate The Embedded PC AHD 1200’s name plate is located on the de- vice front and contains the following information:  Model designation of the unit (in the top section of the cover plate) ...
  • Page 19: Dimensions

    AHD 1200 Embedded PC Technical Information 4.3 Dimensions 4.3.1 Device Dimensions...
  • Page 20: Drill Holes

    AHD 1200 Embedded PC Technical Information 4.3.2 Drill Holes...
  • Page 21: Connections

    Pin 3: RxD, data reception for the AHD 1200 Sig.5: GND: Ground When connecting a GPS receiver or another device, pin TxD is connected to the AHD 1200’s pin RxD, and the device’s ground is connected to the AHD 1200’s “Ground” pin. Opto-IN Four optocoupler inputs, intended for accepting acknowledge- ments.
  • Page 22 AHD 1200 Embedded PC Technical Information The assignment allows for switching to ground or Vcc. Five relay outputs for controlling alarm indicators. Relay-Out The pins are assigned as follows: The relay outputs’ function is determined via configuration with AHD-DeviceConfig. 6 CAN plugs are used for connection to the vessel’s CAN bus sys- tem.
  • Page 23: Transport, Packaging And Storage

    AHD 1200 Embedded PC Transport, Packaging and Storage 5 Transport, Packaging and Storage 5.1 Transport Safety Instructions Improper Transport CAUTION! Equipment damage from improper transport! Improper transport can cause significant equipment damage. Therefore: – Use caution when unloading the packages dur-...
  • Page 24 AHD 1200 Embedded PC Transport, Packaging and Storage Handling the Packaging Materials The packaging materials must be disposed according to current legal regulations and local ordinances. CAUTION! Environmental damages from incorrect dispos- Packaging materials are valuable raw materials and can often be reused or meaningfully processed and recycled.
  • Page 25: Installation And Initial Startup

    AHD 1200 Embedded PC Installation and Initial Startup 6 Installation and Initial Startup 6.1 Safety  Personnel Installation and initial startup may only be performed by special- ly trained professionals.  Only electricians may work on the electrical system. Basic Information...
  • Page 26: Installation

    The product is not connected to the supply voltage and switch- ed off-circuit. Installation Install the AHD 1200 properly in the intended installation loca- tion according to technical specifications or project drawings. Wire all of the unit’s inputs and outputs according to technical...
  • Page 27 AHD 1200 Embedded PC Installation and Initial Startup TIP! On delivery, the AHD 1200 is configured as speci- fied in the project configuration. This includes the integration of the ship’s devices captured by the AHD 1200, the data processing, and the graphic rendering of ship data and control ele- ments on the displays.
  • Page 28: Installation

    AHD 1200 Embedded PC Installation and Initial Startup 6.2.1 Installation CAUTION! Mechanical tension during installation can impair the device’s tightness and lead to equipment dam- age. Ensure that the device is installed on even surfaces or in even panel cutouts without tilting.
  • Page 29: Ground

    6.2.2 Ground CAUTION! Equipment damage and system errors from missing ground! If the AHD 1200 is not grounded, equipment dam- age and system errors may occur. Therefore: Ground the device during installation! When grounding the device, only use the des-...
  • Page 30: Cooling

    AHD 1200 Embedded PC Installation and Initial Startup 6.2.3 Cooling CAUTION! Equipment damage from improper cooling! Improper cooling of the AHD 1200 can lead to equipment damage and system errors. Therefore: – Only install the devices in housings/panels with air vents.
  • Page 31: Updating The Firmware

    AHD 1200 Embedded PC Installation and Initial Startup 6.2.4 Updating the Firmware TIP! Generally, this step is not necessary with factory side configured devices. In some cases, the device firmware must be updated prior to start- ing up the device. For this, contact the manufacturer for further in- formation.
  • Page 32: Initial Startup

    The AHD 1200 and all connected external devices are not con- nected to the power supply or have been wired off-circuit. 1. Establish the 24 V DC power supply for the AHD 1200 accord- ing to technical specifications or project drawings.
  • Page 33: Operation

    The Embedded PC AHD 1200 does not include its own switch for powering the device on and off. The AHD 1200 is powered on by switching on its power supply in the corresponding distribution box. Upon successful startup, the Windows XP Embedded start screen, or another visualization set up in the configuration, is shown on a display connected to the AHD 1200.
  • Page 34: Power Off

    The Embedded PC AHD 1200 does not include its own switch for powering the device on and off. The AHD 1200 is powered off by switching off its power supply in the corresponding distribution box. The PC does not require a special shutdown procedure. The de-...
  • Page 35: Maintenance

    AHD 1200 Embedded PC Maintenance 8 Maintenance TIP! Generally, the Embedded PC AHD 1200 is main- tenance free. Maintenance of the units is limited merely to exter- nal cleansing and inspection. Only use solvent-free, nonabrasive detergents for cleaning. CAUTION! Risk of injury from dangerous voltages and...
  • Page 36: Errors

    AHD 1200 Embedded PC Errors 9 Errors The following table describes errors that can occur when operating the AHD 1200, including information about causes, error recogni- tion, and error correction. 9.1 Safety  Personnel Some work may only be performed by specially trained profes- sionals or the manufacturer.
  • Page 37: Error Correction

    AHD 1200 Embedded PC Errors In Case of Error: As a rule: Determine the cause of the error. Immediately inform a responsible party on-site. Depending on the error type, have an authorized specialist correct it, or correct it on your own.
  • Page 38: Disassembly

    AHD 1200 Embedded PC Disassembly 10 Disassembly After the device has reached its end of life, it must be disassem- bled and disposed in an environmentally safe manner. 10.1 Safety  Personnel Only a specially trained professional may perform the disas- sembly.
  • Page 39: Disposal

    AHD 1200 Embedded PC Disassembly 10.3 Disposal In the absence of a return or disposal agreement, recycle the dis- assembled components:  Scrap metals.  Recycle plastic components.  Dispose the other components according to their material properties. CAUTION! Environmental damages from improper dispos-...
  • Page 40: Index

    AHD 1200 Embedded PC Index 11 Index Name Plate ............18 About this Manual ..........6 AHD Display Designer ........16 Operation ............33 AHD-DeviceConfig ..........16 Power Off ............34 Power On ............33 Configuration............16 Selecting the Video Source ......33 Cooling ...............
  • Page 41: List Of Abbreviations

    AHD 1200 Embedded PC List of Abbreviations 12 List of Abbreviations ABS – American Bureau of Shipping PLC: Programmable Logic Controller BV – Bureau Veritas RINA – Registro Italiano Navale RMRS – Russian Maritime Register of Shipping CAN – Controller Area Network CRS –...
  • Page 42 Devices, System Installation, Monitoring and Control Technology, Ship Automation Böning Automationstechnologie GmbH & Co. KG Am Steenöver 4 D-27777 Ganderkesee E-Mail: info@boening.com Internet: www.boening.com Texts and illustrations not binding. We reserve the right to make changes due to technical improvements.

Table of Contents