Do you have a question about the SUPERCIKKI 80 and is the answer not in the manual?
Questions and answers
Summary of Contents for Plasson SUPERCIKKI 80
Page 1
L i v e s t o c k Gas Space Heater SUPERCIKKI 80 Feeding Drinking Climate Housing Installation and Operation Instructions Global Presence - Local Commitment Feeding Drinking Climate Housing...
Page 2
FORBIDDEN = where the action MUST NOT be WARNING = where the work to be carried out carried out requires special care and suitable training FORBIDDEN = where the action MUST NOT be carried out | Gas Space Heater SUPERCIKKI 80...
Page 3
Feeding Drinking Climate GENERAL WARNINGS After removing the packaging check that all the equipment is present and intact. If there is any failure to correspond with order contact the manufactorer agent who sold the equipment.. The equipment must be installed by an accredited company; at the end of work it has to issue to the owner’s machine the Conformity Declaration that the installation has done in accordance with locally and nationally applicable regulations and the instructions given by the manufactorer in this manual.
Page 4
It is forbidden to touch the exhaust flue as it may reach temperatures which are dangerously high to the touch during normal working. It is forbidden to use adapters, multiple sockets and extension cables for the equipment’s electrical connection | Gas Space Heater SUPERCIKKI 80...
Page 5
Feeding Drinking Climate IDENTIFICTION OF THE EQUIPMENT The equipment is identifiable by the Technical Plate bearing its main technical and performance details. If the plate is lost or damaged ask for a duplicate from manufactorer’s technical assistance dept. IDENTIFICATION DATA OF MANUFACTURER WARM AIR HEATER Model Registration n°...
Page 6
As solenoid valve The multifunctional safety and regulatory gas solenoid valve consists of: • A safety solenoid valve • A regulating solenoid valve • A pressure regulator (depending on the country destination) • A gas filter | Gas Space Heater SUPERCIKKI 80...
Page 7
Feeding Drinking Climate Burner assem bly Consisting of: • Gas injector • Cast iron Multigas burner • Ignition electrodes • Flame detection electrode Control and protection equipm ent This is electronic with ionisation flame detection circuits and capacitive discharge ignition. The equipment controls and monitors the working of the equipment, taking care of the following tasks: •...
Page 8
Automatic safety thermostat Flame detection electrode Flow switch Ignition electrodes Manual safety thermostat Gas injector Terminal air diffuser Gas solenoid valve Casing Centrifugal fan Hoisting eyebolts Electric board Fan motor Red light button Device mixer air-gas | Gas Space Heater SUPERCIKKI 80...
Page 9
Feeding Drinking Climate TECHNICAL DATA DESCRIPTION UNIT OF MEAS. DATA Nominal thermal capacity 80,0 kcal/h 68.800 Air flow M 3 /h 2.000 Thermal haed °K ∼ 145 Throw distance Sound pressare level DB(A) Type Electrical supply 230V 50Hz ∼ Power of centrifugal fan motor 0,373 Centrifugal fan motor absorption Condenser capacity...
Page 10
In ther version with selector switch a 3 position changeover switch and a supplementary Cable for centrifugal fan entry cable relay. In ther version with selector switch a 3 position changeover switch and a supplementary relay. | Gas Space Heater SUPERCIKKI 80...
Page 11
Feeding Drinking Climate WIRING DIAGRAM WITHOUT CHANGEOVER SWITCH VERSION Electrical diagram for electrical supply single phase, phase-neutral 230V 50Hz Fase+Neutro+Terra RESET Electrical terminal block Safety fuse 6,3 A (∅5 x 20) delayed for motors ignition Luminous release button Manual reset limit thermostat Electronic control and checking unit Relay centrifugal power fan motor Hot surface ignition electrode...
Page 12
Not included in the delivery, it should be installed by the customer or the fitter. Attention! The electronic unit needs for a correct function an electric supply line with neutral. If this neutral line doesn’t exist, it is necessary to install an insulation transformer. | Gas Space Heater SUPERCIKKI 80...
Page 13
Feeding Drinking Climate Table for version with changeover switch. CMT in position AUTO → IV open (NO ventilation) → The heater is stopped TA open (NO heat request) ↓ IV open (NO ventilation) → The heater starts in heating TA closed (YES heat request) ↓...
Page 15
Feeding Drinking Climate RECEIPT OF PRODUCT The heater is delivered with: • Instruction manual • Warranty certificate • Output air duct Kit • Gas conversion Kit (natural gas or LPG to work with its predisposition) and 4 hoisting eyebolts, which are enclosed in a transparent plastic bag inside the heater.
Page 16
The heater must be located in a free area as shown in the figure below. The space indicated is necessary so that there will be no barriers for the air flow and that normal cleaning and maintenance operations can be carried out. | Gas Space Heater SUPERCIKKI 80...
Page 17
Feeding Drinking Climate INSTALLATION Example of installation inside the room to be heated with complete air recirculation. Suspended heater with chains or steel wire Air heater Hot air intake Hoisting eyebolt Suspension chains – wires (*) (*) not included Heater installed on support brackets 1.
Page 18
Shutter position with no working fan Shutter position with working fan 1. Air heater 2. Support brackets (*) 3. Final air diffuser 4: Output air duct with overpressure air shutter (*) (*) Not included | Gas Space Heater SUPERCIKKI 80...
Page 19
Feeding Drinking Climate Example of installation outside the room, with total or partial internal recirculating: Air inlet completely outside Air inlet partial (inside and outside) Air inlet completely inside 1. Air heater 2. Support brackets (*) 3. Final air diffuser 4.
Page 20
During operation of the heater, the air diffuser should not be touched, since it will reach dangerous temperatures The assembly and the installation of the final warm air diffuser is compulsory, as it avoids the accidental contact with the fan blades | Gas Space Heater SUPERCIKKI 80...
Page 21
Feeding Drinking Climate OUTPUT AIR DUCT WITH OVERPRESSURE AIR SHUTTER (ACCESSORY ON REQUEST) If the heater will be installed outside the room to be heated, it will be necessary to install an air duct through the wall. This air duct is supplied with an air shutter working by gravity which closes the outlet of warm air when the heater is not working.
Page 22
Discard the unwanted piece (pos. 3) c. Install the shortened output air duct with overpressure air shutter (pos. 2) on the warm air heater’s flange (pos. 1) and install the final air diffuser (pos. 4) | Gas Space Heater SUPERCIKKI 80...
Page 23
Feeding Drinking Climate AIR RECIRCULATING UNIT WITH AIR DAMPER (ACCESSORY ON REQUEST) If the heater is to be installed outside of room, to be heated, but it is preferred to recycle the internal air it will be convenient to install the air recirculating unit with damper It has a damper to mix the inside-outside air quantity, that can be set in several steps.
Page 24
View holes from the outside of the wall where the heater is installed Execution hole for supporting brackets installation on the bottom of the heater and output air duct View holes from the outside of the wall where the heater is installed | Gas Space Heater SUPERCIKKI 80...
Page 25
Feeding Drinking Climate GAS LINE CONNECTION Preregulating. The heater is tested and regulated in the factory, so to work with the gas type as indicated on the label, which is positioned near the gas junction. A conversion kit, is also enclosed to change to other gas types present in the Country of destination.
Page 26
1. Warm air heater 2. Electrical cable 3. Electrical cable entry hole 4. Cable grommet It is forbidden to insert electrical cables inside the equipment other than in the positions specifically provided for in this manual. | Gas Space Heater SUPERCIKKI 80...
Page 27
Feeding Drinking Climate Electrical connection To connect up the mains supply, :do as follows: • Open the burner door • Remove electrical panel cover • Pass the cables through the cable channels and cable gummed • Connect up as shown in the diagram •...
Page 28
Country destination. The gas connection must be carried out only by a technical staff who are authorised and competent respecting the rules, being in effect in the different destination countries of the product. | Gas Space Heater SUPERCIKKI 80...
Page 29
Feeding Drinking Climate Here below are tables which explain the configuration, as carried out by the Factory and the operation for changing the gas type. Preregulation in the factory Propane gas G31 Gas conversion kit Natural gas G20 Butane gas G30 I nstruction for gas conversion: From Propane gas G31 to Butane...
Page 30
Loosen the screws , and so remove the burner and the frame carrying the electrodes WARNING! The seal gasket must be checked after each nozzle change.. | Gas Space Heater SUPERCIKKI 80...
Page 31
Feeding Drinking Climate SOLENOID VALVE ADJUSTMENT Setting the pressure regulator of the gas control valve The gas control valve is supplied with a pressure regulator with a working range of 0-30 mbar, to set the correct pressure at the gas injector. It is Inlet pressure measuring point before the pressure used to work with Natural gas G20, if Propane gas regulator...
Page 32
It is prohibited to use liquids to clean internal parts of the equipment. It is prohibited to use liquids to clean internal parts of the equipment. USE COMPRESSED AIR ONLY USE COMPRESSED AIR ONLY USE COMPRESSED AIR ONLY | Gas Space Heater SUPERCIKKI 80...
Page 33
Feeding Drinking Climate PERIODIC MAINTENANCE With interval that must be reduced in case of installation in heavy conditions, but at the end of each cycle, following maintenance and checks have to be done: • Clean accurately, but with compressed air only all the internal walls of the air heater, ignition electrodes and flame detection electrodes, burner, safety flow switch and fan motor.
Page 34
Defective flow switch Replace flow switch Defective fan (motor) Replace fan and/or condenser Check the fuse of electronic Defective electronic equipment control unit Replace the electronic control unit | Gas Space Heater SUPERCIKKI 80...
Page 35
Feeding Drinking Climate FAULT CAUSE SOLUTION The burner stops abnormally Excessive resistance of outlet Check the hot air outlet for and casual air duct obstructions of flow switch Defective flow switch Replace flow switch ...
Page 36
L i v e s t o c k Global Presence – Local Commitment Maagan Michael, D.N. Menashe, 3780500, Israel Tel: +972-73-2413001, Fax: +972-73-2333711 info@plassonlivestock.com | www.plassonlivestock.com Feeding Drinking Climate Housing...
Need help?
Do you have a question about the SUPERCIKKI 80 and is the answer not in the manual?
Questions and answers