Do you have a question about the IX30-Z-Wave and is the answer not in the manual?
Questions and answers
Summary of Contents for Kaipule IX30-Z-Wave
Page 1
IX30-Z-Wave is a digital micro-control intrusion detector adopting Energy Accumulation Logical Processing & Random Dynamic Time Segmentation Technology. With precise columnar Fresnel lens, IX30-Z-Wave can increase its energy receiving efficiency and sensitivity without false alarm. In conjunction with advanced software technology, it will make an accurate judgment between real intruder &...
Page 2
Optical Lens Data Infrared Area:11+8+6+5(typical) Max. Detection Square:10m*10m/90° RF Frequency: 908.4MHZ Alarm Indicator: LED indicator on <= 1s Mount Bracket: 1 PCS (default) Mounting Height: 2.2~2.7m (87~106 inch) Operating Temperature: -20℃~50℃ Storage Temperature: -20℃~60℃ Anti White Light (Indoor): >6500LUX Dimension: 110*62*47mm (L*W*H) Installation Ⅲ...
Page 3
6. When the detector passed the walking test, please adjust the test mode to normal mode Please don’t invert the detector while installing. Here advice user to have a walk test every week. V. IX30-Z-Wave Operation 1. Add & Remove Add : enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the door sensor...
Page 4
support 2 devices. It will send “NOTIFICATION_REPORT”to the device in Lifeline group when the door sensor is opened / closed, tamper switch is triggered / recovered. When in low battery status, door sensor will send “BATTERY_REPORT” to Lifeline group device periodically. The door sensor will send “DEVICE_RESET_LOCALLY_NOTIFICATION”...
Page 5
If there is any device under Association Group2, the door sensor will send “BASIC SET” command to control those devices when the door sensor is triggered. For example: when the door sensor is triggered, it sends adjustable parameter “BASIC SET” command to a lamp under Group2, you can adjust the lamp’s luminance through the parameters of this command;...
COMMAND_CLASS_BATTERY COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY Commands to Control Other Devices: COMMAND_CLASS_BASIC 8. Cautions Our products have been quite stable in performance, but as the product itself low point transmission capacity and conditional application, it still has limits in usage. Following are the situations that may occur: a) Indoor environmental restrictions, such as co-frequency interference, complicated geographical environment of communication etc...
Need help?
Do you have a question about the IX30-Z-Wave and is the answer not in the manual?
Questions and answers