  • Page 2 Linking up the smoke detectors ..........7 Creating a large group ...............7 Creating single groups ...............7 Maintenance test ................8 Battery ..................8 False alarm ................8 Environmental protection information ........8 Bedienungsanleitung www.mumbi.de/manuals Mode d‘emploi www.mumbi.de/manuals Istruzioni per l’uso www.mumbi.de/manuals Manual de instrucciones www.mumbi.de/manuals...
  • Page 3: Scope Of Delivery

    User manual m-RMF150 - Electronic Smoke Detector Scope of delivery • Smoke detector • 1 x 9 volt battery + 3 x 1.5 AA batteries (per smoke detector) • Assembly set per smoke detector • Instructions Specifications Alarm signal: ≥ 85dB...
  • Page 4: Principles Of An Escape Plan

    • Only test the smoke detector with the TEST–button or use a commercially available test spray. Under no circumstances should you use other materials to generatesmoke for testing, since these can be harmful to your health and cause damage to the smoke detector. •...
  • Page 5: Safety And Maintenance Information

    50cm = Please do not install smoke detec - tors in this area. • Do not install the detectors in rooms with high humidity (shower rooms, baths, kitchens or laundry rooms), rooms with large temperature fluctuations (over 40°C or under –5°C) or where the detectors can be contaminated by vehicle exhaust gases, dust and dirt (garage, furnace room, etc.) →...
  • Page 6: Installation

    These materials attack the surfaces of the devices and their vapours are both harmful to health and are explosive. Do not use any pointed tools, such as screwdrivers, wire brushes, to clean the devices. ➀ ➁ Installation 1. Twist off the assembly plate from the smoke detector. (A) ...
  • Page 7: Linking Up The Smoke Detectors

    Linking up the smoke detectors We recommend performing the registration of all smoke detectors on a table. The following steps must be carried out within 20 seconds. Please read the inst- ructions before performing the individual steps. 6. Take a smoke detector from the group and designate it as the “master”. The remaining detectors are all assigned to be secondary detectors (“slaves”).
  • Page 8: Maintenance Test

    Maintenance test • Test your smoke detectors at least once a month by pressing the test button (C); all the devices will sound the alarm. • Blow the sensors with a commercially available compressed air spray at least once every 6 months to remove dust and dirt. Battery The detector works with one 9V block battery and three 1.5V AA batteries.
  • Page 9 Manufactured for Smartwares Safety & Lighting BV, Broekakkerweg 15, 5126BD Gilze The Netherlands, +49(0)1805010762, www.smartwares.eu Imported for Claus GmbH, Sigsfeldstraße 4, 45141 Essen, www.mumbi.de...