BEDIENUNGSANLEITUNG
ADC F466-S:
ADC F466-D:
ADDAC F446:
DAC F466-S:
DAC F466-D:
Inhalt / Content
Allgemeine Sicherheitshinweise
Das Erde / Masse Konzept
Anschluss / Steckerbelegung
Bedienungsanleitung
General Safety Instructions
The Earth / Grounding Concept
Connection / Connectors
User´s Manual
Technische Daten / Technical Specifications
PCB Layout / Jumper settings
Konformitätserklärung / Conformity Statement
USER´s MANUAL
ADC F444
ADDAC F446
DAC F466
AVAILABLE MODELS
2-ch Analog-Digital Converter
4-ch Analog-Digital Converter
2/2-ch A/D – D/A Converter
2-ch Digital-Analog Converter
4-ch Digital-Analog Converter
development and
manufacturing of
audio electronic
Seite / Page
2
3
4
6
14
15
16
18
26
27
28
Tel. +49 (0) 7531 73678
Turmstrasse 7a
78467 Konstanz
Fax +49 (0) 7531 74998
www.lake-people.de
GERMANY
Revision 2 IV/2007
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADC F466-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lake People ADC F466-S

  • Page 1 BEDIENUNGSANLEITUNG USER´s MANUAL ADC F444 ADDAC F446 DAC F466 Revision 2 IV/2007 AVAILABLE MODELS ADC F466-S: 2-ch Analog-Digital Converter ADC F466-D: 4-ch Analog-Digital Converter ADDAC F446: 2/2-ch A/D – D/A Converter DAC F466-S: 2-ch Digital-Analog Converter DAC F466-D: 4-ch Digital-Analog Converter...
  • Page 2: Allgemeine Sicherheitshinweise

    Allgemeine Sicherheitshinweise WARNUNG Bitte lesen Sie die folgenden Sicherheitshinweise: Wasser, Flüssigkeiten, Feuchtigkeit: Das Gerät soll nicht in der Nähe von Wasser- oder Flüssigkeitsquellen benutzt werden. Das Gerät soll nicht in Bereichen grosser Feuchtigkeit betrieben werden. Achten Sie darauf, dass das Gerät nicht in Flüssigkeiten fällt, oder dass Flüssigkeiten durch die Gehäuseöffnungen eindringen können.
  • Page 3: Das Erde / Masse Konzept

    Das Erde / Masse Konzept DIGITAL transformer balanced output ANALOG transformer balanced output Ground Lift Jumper: XLR male XLR male G(round) L(ift) C(ase) DIGITAL transformer balanced input ANALOG transformer balanced input Ground Lift Jumper: XLR female XLR female G(round) L(ift) C(ase) DIGITAL unbalanced output ANALOG electronically balanced output...
  • Page 4 Anschluss / Steckerbelegung für digitale Signale DIGITALE SIGNALE Symmetrisches Kabel (Signal) an Trafosymmetrischen Eingang XLR MALE PLUG Shield / Abschirmung = Signalmasse = Pin 1 Hot / + Phase = Pin 2 Cold / - Phase = Pin 3 Das Steckergehäuse sollte nicht mit der COLD Abschirmung des Kabels verbunden werden.
  • Page 5 Anschluss / Steckerbelegung für analoge Signale ANALOGE SIGNALE Symmetrisches Kabel (Signal) an (Trafo)symmetrischen Eingang XLR MALE PLUG Shield / Abschirmung = Signalmasse = Pin 1 Hot / + Phase = Pin 2 Cold / - Phase = Pin 3 Das Steckergehäuse sollte nicht mit der COLD Abschirmung des Kabels verbunden werden.
  • Page 6 ALLGEMEINES DAS GEHÄUSE Der LAKE PEOPLE Wandler F444 / F446 / Das geerdete Gehäuse besteht aus 1 - 2 mm F466 bestehen aus ein oder zwei A/D und/oder starkem Edelstahl. Dies garantiert eine hohe D/A Wandlerbaugruppen höchster Qualität. mechanische Stabilität und Widerstandsfähig- A/D Wandlerbaugruppen verfügen zusätzlich...
  • Page 7 DAS SYNC MODUL (nur bei A/D Wandlern vorhanden) DIE EXTERNEN SYNC EINGÄNGE Ein nicht gültiges Signal oder ein Signal aus- serhalb des Bereichs 28 kHz > Fs > 210 kHz Drei verschiedene Sync-Eingänge befinden wird durch die rote "ERRor" LED angezeigt. sich auf der Rückseite des Gerätes und sind Weil hierbei die interne Taktaufbereitung unter- entsprechend bezeichnet.
  • Page 8 Am externen Sync-Eingang muss einmal für kurze Zeit ein gültiges Signal gelegen haben. Diese Zeitspanne wird benötigt um die externe Frequenz zu detektieren und den internen Oszillator vorzubereiten. Die externe Frequenz muss sich in einem Bereich von +/- 200 Hz um die vorhan- denen interen Frequenzen befinden.
  • Page 9 DAS ANALOG-DIGITAL WANDLER MODUL (wenn vorhanden, 1 oder 2 Module) HINWEIS: DIE AUSSTEUERUNGSANZEIGE Der ADC F444 kann ein oder zwei ADC-Modu- le aufnehmen. Die getätigten Einstellungen am Sie besteht aus jeweils 8 LEDs für den linken Sync-Modul gelten immer für beide ADC´s. und rechten Kanal.
  • Page 10 DAS ANALOG-DIGITAL WANDLER MODUL (wenn vorhanden, 1 oder 2 Module) Das Datenwort (Professional- oder Consumer- DAS DIGITALE AUSGANGSFORMAT format) ist an allen Ausgängen gleich, unabhängig von der Norm oder Bauweise der Das digitale Ausgangsformat (Professional- Anschlüsse. oder Consumer) ist über den "FORMAT" Die Ausgänge befinden sich auf der Rückseite Schalter an der Sync-Einheit einstellbar.
  • Page 11 DAS DIGITAL-ANALOG WANDLER MODUL (wenn vorhanden, 1 oder 2 Module) HINWEIS: Der DAC F466 kann ein oder zwei DIE EINGANGSWAHL DAC Module aufnehmen. Die Module arbeiten völlig autonom, da sie (bis auf die Spannungs- Mit dem "INPUT"-Schalter auf der Front kann versorgung) getrennt aufgebaut sind.
  • Page 12 DAS DIGITAL-ANALOG WANDLER MODUL (wenn vorhanden, 1 oder 2 Module) HINWEIS: KEY-LOCK unsymmetrischem Abschluss Ausgänge darf der Pin 3 nicht kurzgeschlossen Um eine unbeabsichtigte Bedienung zu ver- werden sondern muss offen bleiben. meiden, kann die Tastatur jedes DAC-Moduls Bei unsymmetrischem Abschluss stellt sich ein verriegelt werden.
  • Page 13 DIE OPTION DIE OPTION "DIGITAL OUTPUTS" "RESAMPLING MODUL" Das Resampling Modul ist ein Sample-Rate Konverter. Dieser isoliert die digitalen Nutzda- ten vom eventuell verjitterten und klangver- schlechternden Eingangdatenstrom und fügt sie in einen eigenen Datenstrom mit 94 kHz Sample-Rate ein. Dieser wird aus einem eige- nen Low-Jitter Generator gewonnen.
  • Page 14: General Safety Instructions

    General Safety Instructions WARNING For your protection, please read the following: Water, Liquids, Moisture: This appliance should not be used near water or other sources of liquids. Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings. Power Sources: The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance.
  • Page 15: The Earth / Grounding Concept

    The Earth / Grounding Concept DIGITAL transformer balanced output ANALOG transformer balanced output Ground Lift Jumper: XLR male XLR male G(round) L(ift) C(ase) DIGITAL transformer balanced input ANALOG transformer balanced input Ground Lift Jumper: XLR female XLR female G(round) L(ift) C(ase) DIGITAL unbalanced output ANALOG electronically balanced output...
  • Page 16: Digital Signals

    Connection / Connectors for digital signals DIGITAL SIGNALS Balanced Cable (Signal) to Transformer Balanced Input XLR MALE PLUG Shield = Signal Ground = Pin 1 Hot / + Phase = Pin 2 Cold / - Phase = Pin 3 The case of the connector should not be wired COLD to the shield of the cable.
  • Page 17 Connection / Connectors for Analog Signals ANALOG SIGNALS Balanced Cable (Signal) to (Transformer) Balanced Input XLR MALE PLUG Shield = Signal Ground = Pin 1 Hot / + Phase = Pin 2 Cold / - Phase = Pin 3 The case of the connector should not be wired COLD to the shield of the cable.
  • Page 18: The Power Supply

    GENERAL THE CASE The LAKE PEOPLE converters F444 / F446 / The grounded case is made of 1 - 2 mm thick F466 consists of one or two A/D and/or D/A stainless steel. This provides high mechanical converter modules of highest quality.
  • Page 19 THE SYNC MODULE (only present with A/D converters) THE EXTERNAL SYNC INPUTS A not valid signal or a signal beyond the range of 28 kHz > Fs > 210 kHz is displayed by the The sync inputs are located on the rear panel red “ERRor”...
  • Page 20: The Mute Button

    As soon as the activated external sync is present again, the unit will switch over to it and the dedicated source LED is lit constantly. A reliable shifting is proceeded under the following circumstances: The external sync input must have had a valid sync signal for a short time.
  • Page 21: The Analog Inputs

    THE ANALOG to DIGITAL CONVERTER MODULE (if present, 1 or 2 modules) Hint: INPUT POTENTIOMETERS ADC F444 may contain one or two A/D mo- dules. The settings of the sync module are By means of two independent gain pots for left valid for both SRC modules.
  • Page 22 THE ANALOG to DIGITAL CONVERTER MODULE (if present, 1 or 2 modules) THE DIGITAL OUTPUTS THE DIGITAL OUTPUT FORMAT The A/D part offers two digital outputs – bal- The digital output format - professional or anced and unbalanced. consumer - is selectable with the "FORMAT"- Independent from their design, data words –...
  • Page 23: The Digital Inputs

    THE DIGITAL to ANALOG CONVERTER MODULE (if present, 1 or 2 modules) HINT: INPUT SELECTION DAC F466 may contain one or two D/A modules. The modules may work totally inde- With the “INPUT” button on the frontpanel one pendendly from each other as they only share of two inputs may be selected.
  • Page 24: The Analog Outputs

    THE DIGITAL to ANALOG CONVERTER MODULE (if present, 1 or 2 modules) When the sample rate of the emphasis signal balanced XLR terminals according to AES 14- is different to 44.1 kHz, wrong conversion of 1992 recommendations: higher frequency analog signals has to be 1 = Ground, 2 = (+) Phase, 3 = (-) Phase calculated.
  • Page 25 THE OPTION THE OPTION "DIGITAL OUTPUTS" "RESAMPLING MODUL" Resampling Module basically sampling-rate converter. It isolates the digital PCM data from the incoming data stream which is eventually affected by jitter and so may cause negative audible effects such as higher distortion. It converts the input data to its own data stream with 94 kHz sample-rate, generated by a low jitter clock.
  • Page 26 TECHNICAL DATA ADC F444 / ADDAC F446 / DAC F466 (All measurements A-weighted, 20 Hz... 20 kHz, 48 kHz internal sample rate, referred to digital full scale and +20 dBu analog input/output level) SYNC MODULE External Inputs: 1 x XLR female, transformer balanced, impedance 110 ohms 2 x BNC, unbalanced, impedance 75 ohms / 10 kOhms Sensitivity: 200 mV at Tnom/2...
  • Page 27 PCB LAYOUT AND JUMPER SETTING A/D-MODUL D/A-MODUL SRC Operation CONFIGURATION of GROUND-LIFT JUMPER (optional) optional DIGITAL OUT MODUL Pin 1 from XLR socket connected to internal 1 - 2 SRC OFF Ground-Plane. Modul 1 ex Works setting (ex Works setting) when SRC option is not present Pin 1 from XLR socket...
  • Page 28: Conformity Statement

    (Mitgliedsnummer: DE 26076388) Member No. : DE 26076388 Für diese Erklärung ist der Hersteller verantwortlich: This declaration is given under responsibility of: Lake People electronic GmbH Turmstrasse 7a, D-78467 Konstanz ----------------------------------------------------------------------------- Konstanz 26.09.2014, Fried Reim, Geschäftsführer / CEO development and Turmstrasse 7a Tel.

Table of Contents