  • Page 1 0482 CLETEF-786 Infrared Thermometer Instruction Manual...
  • Page 2 Thank you for choosing the Clever Choice Duo Ear & Forehead Thermometer, by Simple Diagnostics. The infrared thermometer CLETEF-786 can be used to read body temperature by measuring the ear or forehead temperature, and is suitable for both adult and children.
  • Page 3: Table Of Contents

    Contents 1. The Advantages of Clever Choice Duo ..........1 2. Necessary Safety Instructions .............. 2 3. Product Design ..................4 4. How to Use Forehead Mode ..............5 5. How to Use Ear Mode ................5 6. Sound and Backlight Information ............7 7.
  • Page 4 Simple Diagnostics Inc. Address: P.O. Box 128 Williston Park, NY 11596, USA Tel (USA): 877-342-2385 Tel (Inter.): 1-954-603-0572 Website: www.SimpleDiagnostics.com Email: Sales@SimpleDiagnostics.com...
  • Page 5: The Advantages Of Clever Choice Duo

    1. The Advantages of Clever Choice Duo communications equipment and the CLETEF-786 Infrared Thermometer. The CLETEF-786 Infrared Thermometer is intended for use in an Dual mode (forehead temperature and ear temperature) electromagnetic environment in which radiated RF disturbances are Thanks to dual mode design, you are free to take body temperature controlled.
  • Page 6: Necessary Safety Instructions

    The device is not a continuous monitoring device. transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the CLETEF-786 Infrared CLETEF-786 is not waterproof. Please do not douse it with water Thermometer is used exceeds the applicable RF compliance level above, the or other liquids.
  • Page 7 The CLETEF-786 Infrared Thermometer is intended for use in the Notes: electromagnetic environment specified below. The customer or the user of the CLETEF-786 Infrared Thermometer should assure that it is used in such ☆ If you using the thermometer for the first time, please pull out the an environment.
  • Page 8: Product Design

    Guidance and manufacturer´s declaration – electromagnetic emission The CLETEF-786 Infrared Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the CLETEF-786 Infrared Thermometer should assure that it is used in such an environment. Emissions...
  • Page 9: How To Use Forehead Mode

    CAUTION: pointer towards the eardrum. ● CLETEF-786 Infrared Thermometer needs special precautions 3. Press and release the Ear button. The temperature will be displayed regarding EMC and needs to be installed and put into service on the screen instantly. You can take another measurement when the according to the EMC information provided for in the backlight is off.
  • Page 10 Hold still and keep calm during measurement. range of 96.8°F to102.2°F (36°C-39°C) for ear canal IR thermometers is If Clever Choice Duo is moved to an area with a different ±0.4°F (±0.2°C) and for skin IR thermometers is ±0.5°F (±0.3°C). Note that for mercury-in-glass and electronic thermometers, the requirement ambient temperature, wait 30 minutes before testing.
  • Page 11: Sound And Backlight Information

    12. Technical specifications 6. Sound and Backlight Information Backligh Range Sounds Meaning Product Name Clever Choice Duo Infrared Thermometer Ear temperature mode Product Model CLETEF-786 0-37.4℃ 32.0℉- a long beep Green Acceptable 99.4℉ Applicable standard ASTM E 1965/EN 12470-5 37.5℃-37.9℃...
  • Page 12: Display And Operation Instructions

    7. Display and Operation Instructions This error occurs Contact us. Screen Operating Instructions when data is Sound and backlight Display Displayed State being read from or written into the Measuring Forehead Temperature "ErC" is displayed. memory, or the Position the thermometer at the temperature center of the forehead above the correction is not...
  • Page 13: Cleaning And Disinfection

    Screen Operating Instructions "Cleaning and Disinfection". Sound and backlight Display Displayed State Store the thermometer in a dry, dust-free, and well-ventilated Accessing Reading Memory place. Ensure that the thermometer is not exposed to sunlight. Ensure that the storage and transportation environments meet In the power-off state, press and hold the Ear button for 3-5 these requirements...
  • Page 14 components and should not be used in the presence of large Screen Operating Instructions Sound and backlight electromagnetic interference, (such as near mobile phones and display Displayed State microwaves) Switching between ºF/ºC Please dispose of the product and batteries in accordance with local regulation requirements.