Lily Tech ZL-220A Instruction Manual

Advertisement

Quick Links

1. Features

ZL-220A is an electronic thermostat for cooling. The device is ideally fitted to refrigeration equipment for cold
storage.

2. Main Function

Temperature measurement
Temperature display
Temperature calibration
Blustering when system warning
Sensor problem warning
Defrost control: Periodical defrosting, temperature and time combined criteria, dropping water, and

3. Main Specification

Temperature Sensor:
Setting Range:
Display Range:
Working Temperature:
Storage Temperature:
Humidity:
Power Supply:
Terminal Wire:
Load Current:
Protection Degree:

4. Operation Instruction

4.1 Display Indication

4.1.1 Panel LED Indication

LED
MAX TEMP
MIN TEMP
COOL
suzhoulilytech@hotmail.com
Z
L
-
2
2
0
A
E
Z
L
-
2
2
0
A
E
I
n
s
t
r
I
n
s
t
r
NTC
-40~120℃
-50~130℃
-10~45℃
-30~70℃
5~85%RH (without dewing)
185 ~ 245VAC 50/60HZ
<= 2 * 1.5mm
3A 250Vac(Resistive load)
IP30
On
Set max temperature
Set min temperature
Compressor on
l
e
c
t
r
o
n
i
c
T
l
e
c
t
r
o
n
i
c
T
u
c
t
i
o
n
M
a
u
c
t
i
o
n
M
a
2
2
or 1 * 2.5mm
Off
Set max temperature
(to be set)
Set min temperature (to
be set)
Compressor off
www.suzhoulily.com.cn
Suzhou Lily Tech. Co., Ltd.
h
e
r
m
o
s
t
a
t
h
e
r
m
o
s
t
a
t
n
u
a
l
n
u
a
l
Blinking
Delay protecting now
Page 1, Total pages 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZL-220A and is the answer not in the manual?

Questions and answers

Summary of Contents for Lily Tech ZL-220A

  • Page 1 Suzhou Lily Tech. Co., Ltd. 1. Features ZL-220A is an electronic thermostat for cooling. The device is ideally fitted to refrigeration equipment for cold storage. 2. Main Function ● Temperature measurement ● Temperature display ● Temperature calibration ● Compressor delay protection ●...
  • Page 2 Suzhou Lily Tech. Co., Ltd. DEFROST Defrosting now Dropping water ends Dropping water now 4.1.2 Panel Digit Indication Three red digits display the measured temperature and warning code. Warning Code: Display Code Warning Information Room sensor open circuit Room sensor short circuit...
  • Page 3 Suzhou Lily Tech. Co., Ltd. Defrosting﹙end﹚time 1~180min Defrosting end temperature 0.5~50℃ Dropping water time 0~180min Over temperature warning delay time 0~180 hour 0: Disable after defrost ends 0: Disable Defrost when the device starts 1:Enable Defrost delay time when the device start 0: Disable 0~180min...
  • Page 4 Suzhou Lily Tech. Co., Ltd. temperature (U32)) meets, the defrosting stops. 5.4.2 Manual Forced Defrosting ● When in non-defrosting stage, press and hole 【 ▲】 for 7 seconds, the system starts forced defrosting. When in defrosting stage, press and hole 【▲】 for 7 seconds, the defrosting stops.
  • Page 5: Electrical Connection

    Suzhou Lily Tech. Co., Ltd. ● Under strong electrical and magnetic fields such as under a powerful antenna, or near a huge power motor. ● Ambient temperature changes greatly or quickly, such as before the door of a cold room.

Table of Contents