Table of Contents System overview The system consists of a master control panel and various wire/wireless sensors,once any unusual is detected,the alarm control panel will hoot Control panel layout ----------------------------------------------------------- 01~02 Preparation before Use ---------------------------------------------------------03~04 on-site ,meanwhile, it will send SMS to or call the preset phone numbers. complete wireless design makes it easy to setup and install,it is widely used Connect PSTN Land Line ---------------------------------------------------------...
Rear Side Control Panel Layout Tamper Switch Speaker Front Side GSM Network LED Terminals for RFID Tag Reader / SIM Card Slot Clear Wired Sensors Play Voice Memo AC Adapter Jack Landline Jack Power ON/OFF LCD Display Backup Batteries Up/Down Enter Output Wired Siren (≤...
Insert a SIM Card Preparation before Use This step can be ignored if GSM function is not applied. This alarm control panel features a dual communicator of both PSTN and Insert a GSM SIM card into the card slot according to the mark and lock it. GSM alarm system, If there is an alarm, it will auto dial preset phone numbers either though landline or through GSM network.
Disarm Control Panel Operation Input user code (Default: 1234) or admin code (Default: 123456) first Alarm Control then press the [Disarm button, Arm (Away Arm) the system enter s disarm state when Press the [Arm button on the one beep is heard and the disarm control panel, the system enters arm LED Indicator lights on.
Access Control System Voice Memo Press the [Record Voice Memo button for 1 second to record 10 seconds voice The control panel has a RFID reader for message. The circle Play Voice Memo will be flashing to remind you. Users can touch unlocking the electronic door lock by disarming the center of circle to listen to the voice memo.
Page 7
Main Menu Sub menu 1 Sub menu 2 Sub menu 3 Auto arm time 00:00 In the table below,each colummn represents a menu or a sub menu,Each menu or submebu will be displayed on on of the two lines of LCD display.On Auto arm/disarm Auto disarm time 00:00...
Settings sound a beep,and the LCD will show “ Add OK,Remote 01-30 ”.if the remote already has been added before,the control panel will sound 2 beeps and the LCD will show “ already exists ” Before enter into setting menu,please disarm the system first. Type the Admin password and then press “Enter ”...
Page 9
Delete 24 Hour Sensor: Regardless the system is armed or disarmed, when 24 hour sensors are triggered, system will alarm at once. Delete a RFID tag Delay Sensor: In arm mode, when delay sensors are triggered, system will a)Log on setting menu, press ,choose “Accessories”,press [Ente...
3.System settings Timing to Arm (1)Date and Time a)Log on the menu, press , choose “System Settings”, press [Enter] press a)Log on setting menu, ,choose “System setting”, press press , choose “Auto Arm/Disarm”, press [Enter] [Enter]. press , choose “Auto Arm Time”, press [Enter] press , choose “Date and Time”, press...
Page 11
a) Log on the menu, press ,choose “System Settings”, press Admin Code [Enter]. press , choose “Control by phone”, press [Enter] Your admin code enables you to enter setting menu. press , choose “on” to turn on this function ,choose “off” to turn off this function, press [Enter] to confirm...
Page 12
press , choose “Open Door Code”, press [Enter] Wireless siren d)LCD display will show “Input 4 Digits”, then input 4 digits for code, press [Enter]. Wireless siren is connected to control panel through radio. Default Duress Code: 8888)Input the new Door Open Code, press [Enter] Turn On/Off wireless siren 9)Ring times...
Upload Arm/ Disarm Report to CMS Center a)Log on the menu, press , choose “System Settings”, press [Enter] press , choose “Language”,press [Enter] When this function is enabled, all arm/disarm reports will be uploaded c)Choose the language you wish to change to ,press [Enter] to save.
SMS Operation Entry delay time(0-300sec):0 Set Entry/Exit delay time Exit delay time(0-300sec):0 User can send SMS command to control and configure the control panel. Siren volume (0 mute,1High): Set siren alert time Siren ringing time(1-9min):3 Important: Modify disarm password Disarm password(4 digits):8888 1.only the stored phone number can control and configure the control panel.
Send the SMS command to ZONE05:Entry door sensor control panel Download the APP Search keyword “T6 alarm” in APP store or Google Play to down the App. If the operation succeeded, you will get an “OK” replying Change language Send the SMS command to...
Delete/Edit Accssories You can swipe left the added control panel to delete or tap the control panel to edit. Remote control Turn On/Off password The remote control is dainty and delicate, easy to carry. It can be attached to your You can tap the lock button to turn On/Off the password, after that you should key ring, or just put into your pockets or purses.When you are about to exit or entry enter password to logon.
Disarm Door/Window Contact Press the [Disarm button on the remote The window/door sensor can be installed on doors, windows, and any other objects control, the system enters disarm state when that can open and close. The sensor transmits signals to the control panel when a two beeps are heard and the disarm LED on magnet mounted near the sensor is moved away.
Page 18
Test PIR Motion Detector 1. Press the back cover and slide down to r emove the back cover logic control processing technology and intelligent The detector adopts digital 2. Remove the insulating strip. The contact works immediately analysis algorithm, effective resolution of interfering signal and human movement 3.
Page 19
Working Mode Test Testing mode 1. Remove the insulating strip 2. Arm After self-testing, the detector enter Press the buckle to open the back Press the [Arm button on the cover. Remove the insulating strip. remote control. The system is in the testing mode, and detects once After 30-second self -testing, the armed state.
Page 20
Installation 3. Testing Press the test button on the back o f the detector , walk in the detection scope and watch 1. Choose installation place the LED indication to make sur e the detector is working. It is recommended to mount it at the height of 2m from the ground. (For installation notices, please see page 21-22) 4.
Page 21
Installation Notices 3. Avoid facing to glass windows or doors Pay attention to the following during installation: Strong light interferes with detection sensitivity. In addition, complicated 1. Mount the detector to a location close to the entry or exit situations, such as traffic flow, stream of The detector aims at preventing intrusion.
RFID tag Maintenance RFID tag is used to disarm your system or unlock the electronic lock. the control panel The alarm system features unique and brilliant design and craftwork. Please use it with will send a SMS notification to the first stored caution.
Specifications Control Panel Phenomena Cause of Malfunction Troubleshoot Method Open battery compartment, Power Supply Input DC 12V 500mA, 6Wh Power switch is off turn on the power Standby Current < 90mA No response from Contact local main power control panel AC Power failure Alarm Current <...
Wireless Door/Window Contact Disclaimer Power Supply DC 12V (23A Battery x 1 pc) < 35uA Static Current Dear users: < 10mA Alarm Current We have reviewed this manual thoroughly in order that it will be an easy to use guide <...
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Need help?
Do you have a question about the T6 and is the answer not in the manual?
Questions and answers