Fujitsu teamserver M851i Configuration Manual page 27

Table of Contents

Advertisement

Product
Produt ID
HDD-18GB
GP5-HDH81
HDD-9GB
GP5-HDH93
HDD-4GB
GP5-HDH45
HDD-9GB
GP5-HDH95
HDD-4GB
GP5-HDH46
HDD-9GB
GP5-HDH92
HDD-4GB
GP5-HDH44
HDD-9GB
GP5-HD9G2
HDD-4GB
GP5-HD4G5
HDD-8GB(EIDE)
GP5-HD8E1
HDD-4GB(EIDE)
GP5-HD4E1
HDD-9GB
GP5MHDH9GA
HDD-4GB
GP5MHDH4GA
DAT unit (DDS-3)
GP5UDT301
Tape unit (SLR5)
GP5USL501
DLT unit
GP5UDL201
DLT unit
GP5-DL351
Tape unit (MLR3)
GP5-ML301
TRAVAN NS unit(NS20)
GP5-NS201
Redundant Power Supply Unit GP5UPU131
teamserver Hardware
Models
- - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - -
18.2GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug
for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug
for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
4.5GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug
for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for G8xxi
4.3GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for G8xxi
9.1GB,Ultrawide SCSI,7200rpm,SCA2 80pin,Hotplug for C8xxi
4.3GB,Ultrawide SCSI,7200rpm,SCA2 80pin,Hotplug for C8xxi
9.1GB,Ultrawide SCSI,7200rpm,68pin, Non Hotplug
for C8xxi(Mounted in Non Hotplug bay),C3xxi
4.3GB,Ultrawide SCSI,7200rpm,68pin, Non Hotplug
for C8xxi(Mounted in Non Hotplug bay),C3xxi
EIDE,5400rpm, 8.4GB, for C320i/310i/300i
EIDE,5400rpm, 4.3GB, for C320i/310i/300i
9.1GB,Ultrawide SCSI,7200rpm, Hotplug
Only for Hard Disk Cabinet(GP5MS621S,GP5MS621SA)
4.3GB,Ultrawide SCSI,7200rpm, Hotplug
Only for Hard Disk Cabinet(GP5MS621S,GP5MS621SA)
DDS-3 (12-24GB) *The backup utility can be used with the NTBACKUP for Windows
NT4.0 and ARC serve for Windows NT6.0.(Windows NT3.51 is not supported), The
ARC serve for Windows NT6.0.needs Service Pack 3 or greater. Media is not
included. Only one can be mounted in the lowest 5''bay (G8xxi/C8xxi),SCSI2
SLR5 (4-8GB) Backup utilities: NTBACKUP,SBACKUP,ARCserve for Windows
NT4.0,ARCserve for Netware 6.5 Media is not supplied. SCSI2
DLT4000SE Narrow (20-40GB)
Required S/W :ARCserve for Windows NT6.0 or greater (Windows NT4.0),,
ARCserve Storage Suite 6.5 or greater(BackOffice small BusinessServer 4.0)
*NTBACKUP,SBACKUP can not be used as a backup device. Two bays required and
occupied. Cleaning cartridgex1/Data cartridgex1 is attached. SCSI2
DLT7000SE Wide (35-70GB)
Required S/W :ARCserve for Windows NT6.0 or greater (Windows NT4.0), ARCserve
Storage Suite 6.5 or greater(BackOffice small BusinessServer 4.0)
*NTBACKUP,SBACKUP can not be used as a backup device. Two bays required and
occupied. SCSI Adapter(GP5-125)is required to connect. Cleaning cartridgex1/Data
cartridgex1/Internal SCSI cable(with terminal register)is attached.
MLR3 (25-50GB)
The backup utility can be used with NTBACKUP, ARCserve for WindowsNT J6.5
L20(Windows NT4.0), NTBACKUP, ARCserve Storage. SCSI
Adapter(GP5U121/GP5-125)is required to connect.
TRAVAN NS20 (10-20GB)
The backup utility can be used with NTBACKUP, ARCserve for WindowsNT J6.5
L20(Windows NT4.0), NTBACKUP, ARCserve Storage Suite J6.5
Redundant PSU (450W)
27
Remarks

Advertisement

Table of Contents
loading

Table of Contents