  • Page 1 OPERATION & INSTRUCTION MANUAL (3kW – 12kW Steam Generator & Control Panel)
  • Page 2: Table Of Contents

    Table of Contents Safety Warnings ………………………………………………………………… Safety Warnings in French ………………………………………………………… Part 1: Steam Generator Installation Update Bulletin ……………………………………………………………. 4 Users Instructions ……………………………………………………………. 5 Choose your type of machine ……………………………………………………………. 5 Choosing a proper location ……………………………………………………………. 5 Steam equipment installation diagram…………………………………………………………. 6 Installation of the pipeline …………………………………………………………….
  • Page 3: Safety Warnings

    WARNING! To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. WARNING! To reduce the risk of injury: a. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving. b.
  • Page 4: Safety Warnings In French

    DANGER! Afin de réduire les risque de blessures, ne jamais autoriser des enfants à utiliser ce appariel, sauf s’ils sont étroitement surveillés, à tout moment DANGER! a) Les cabines où de la vapeur est introduite peuvent comporter des surfaces humides et donc glissantes. La plus grande prudence est de rigueur au moment où...
  • Page 5: Installation Update Bulletin

    This will make the electrical connections easier. Installation of 6KW When using the connection terminal block, the connection can become loose due to expansion and contraction from the heat and the small vibrations caused when the unit is running.
  • Page 6: Users Instructions

    Part 1: Steam Generator User instructions Attention: We are not responsible for the malfunction and damage from improper installation that does not comply with the user’s manual. Make sure the model and the accessories are correct, including the voltage input. Make sure the steam power is matched with the dimensions of the sauna room.
  • Page 7: Steam Equipment Installation Diagram

    Attention: The steam generator (including the controller) are UL approved. Installation drawing of the steam generator A t t e n t i o n : T h e d r a w i n g i s o n l y f o r e x p l a n a t i o n .
  • Page 8: Installation Of The Pipeline

    Steam pipe (3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'') Do not install any valves in the steam pipes. The steam can never be obstructed. Install a brass or copper steam pipe(3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'') as connector between the steam outlet and the steam nozzle.
  • Page 9 Attention: Please consult your distributors of building materials like acrylic, fiber glass or other heat resistant sheet about the installation and position of steam nozzle. It is suggested that MS-103412 heat resistant material is used. n o n - h e a t - r e s i s t a n t m a t e r i a l l i k e a c r y l i c...
  • Page 10: Steam Generator Blueprint

    Blueprint for the steam engine 395mm 142mm 304mm 43mm Steam outlet Safety valve Water inlet Water drainage 72mm Fuse for wire power supply C o n t r o l l e r w i r e Power wire hole and light wire hole Fuse for wire power supply...
  • Page 11 535mm 435mm 234mm Steam o utlet Safety valve Water inlet Water drainag e Fuse for wire power supply C o n t r o l l e r w i r e Po wer wire hole an d light wire hole Fuse for wire power supply Attention: Keep the steam engine clean.
  • Page 12: Electric Requirements

    Type Electricity supply room (m current (A) wire ( A W G) 220-240V / (1PH/2PH) 27.3A 10# or 6.0mm GS08-6kW 208V / (3PH) 16.7A 12# or 4.0mm 380-415V / (3PH) 12# or 2.0mm 220-240V / (1PH/2PH) 8# or 8.0mm GS08-9kW...
  • Page 13: Power Line Assemble Illustration

    Assembly graph for power wire Attention: To avoid the damage to the equipment, do not connect strong electric current to the component directly. WARNING! This graph is for explanation only. For actual installation, refer to national and local electric codes and consult with a professional electrician. Power connection terminal (3-12k W) (6-18k W)
  • Page 14: Wiring Diagram 380-415V (3Ph)

    Wiring Diagram 380-415V (3PH) S u p p l y W a te r L e v e l S e n so r T o C o n t r o l P a n a l R e d ( S h o r t P i n ) B l a c k ( L o n g P i n ) T e r m i n a l B l o c k Y e l l o w ( M i d d l e...
  • Page 15: Wiring Diagram 208V (3Ph)

    Wiring Diagram 208V (3PH) S u p p l y W a t e r L e v e l S e n s o r T o C o n t r o l P a n a l R e d ( S h o r t P i n ) T e r m i n a l B l o c k B l a c k ( L o n g P i n )
  • Page 16: Wiring Diagram 220-240V (1Ph/2Ph)

    Wiring Diagram 220-240V (1PH/2PH) S u p p l y W a t e r L e v e l S e n s o r T o C o n t r o l P a n a l R e d ( S h o r t P i n ) T e r m i n a l B l o c k B l a c k ( L o n g P i n )
  • Page 17: Installation Of The Top Light

    S u p p l y W a t e r L e v e l S e n s o r T o C o n t r o l P a n a l R e d ( S h o r t P i n ) T e r m i n a l B l o c k B l a c k ( L o n g P i n ) Y e l l o w ( M i d d l e...
  • Page 18: Steam Generator Configuration

    Steam Generator Configuration Enclosure Water drain valve Terminal block Insulation bracket Subsidiary water tank Fuse Circuit board Main water tank Ground connector Steam Outlet Heating Element Relay Pressure relief valve 221 F Hi-limit Water level sensor 221 F Hi-limit Water fill valve Transformer - 17 - Rev 4/2015...
  • Page 19: Troubleshooting Guide

    Trouble shooting: Trouble Causes of Trouble Trouble-Shooting Method The fuse is burned. Change the fuse (on the shell The wire connection terminal is loose. 0.8A/250V) The machine does not start when power is Bad Contact in the connection wire Plug-in the wire connection terminal supplied between the controller and the steam Make sure the steam engine and...
  • Page 20: Specification

    Specifications Important: The list below is for reference only. In actual checking and repairing, based on the national and local codes, ask professional service personnel for advice. Power Output 4.5kW 7.5kW 10.5kW 12kW 15kW 18kW Potency Error ±10% ±10% ±10% ±10% ±10% ±10%...
  • Page 21: Part 2: Control Panel

    Part 2: Control Panel Attention: Before installing the controller, make sure the steam generator is shut off otherwise damage may occur. Do not use a controller inconsistent with the steam generator, do not use the controller to operate steam generator of other brand. The instructions include important safety, operation and maintenance information.
  • Page 22: Controller Installation Instruction

    Controller Installation instruction Attention: Before installing the controller, make sure the steam engine is shut off. Step one Determine the installation location of the controller. For installation: 4 -5feet away from the ground. Locate controller on separate wall from steam nozzle. Do not expose yourself to the direct spray of steam.
  • Page 23: Temperature Detector Installation

    Temperature detector installation The position of the temperature sensor should be within 4-5ft above the ground. Try to avoid installing near the steam mouth or the opening side of the steam room door. As shown in Fig.1, drill a small hole (10mm) in the selected position. Apply silicone along the edge of the back of the detector foundation (as shown in Fig.2).
  • Page 24: Operating Instructions

    Operation Instruction: When power supply is applied to the steam box system the RED stand-by light will be illuminated. (see Illustration of the controller panel for location) Pressing the ON/OFF button will start the system. The steam box will fill with water. This will take a few minutes; the water may cycle on and off a few times as the water tank fills.