Triton TRIT001-US Installation Manual And User's Manual

Pool alarm. fall detector for swimming pool

Advertisement

Quick Links

T
O READ CAREFULLY AND TO KEEP FOR LATER LOOK UP
1
Introduction - Important Safety Precautions ............................................................................................. 2
2
Checking the package .................................................................................................................................... 3
3
Quick Start Guide .......................................................................................................................................... 4
4
Operating principle........................................................................................................................................ 5
5
TRITON™ installation.................................................................................................................................. 9
5.1
Placing the Batteries ............................................................................................................................... 10
5.2
Location choice....................................................................................................................................... 10
5.3
Temporary installation ............................................................................................................................ 11
5.4
Installation Tests ..................................................................................................................................... 11
5.5
Final installation ..................................................................................................................................... 12
6
Recommendations for remote siren installation........................................................................................ 13
7
TRITON™ Operating principle ................................................................................................................. 15
7.1
I want to swim ........................................................................................................................................ 15
7.2
Automatic reset....................................................................................................................................... 16
7.3
Manual reset............................................................................................................................................ 16
7.4
Too much wind ....................................................................................................................................... 16
7.5
Attenuated siren mode ............................................................................................................................ 17
7.6
Password Change mode .......................................................................................................................... 17
7.7
OFF mode ............................................................................................................................................... 17
7.8
Replacing the batteries............................................................................................................................ 18
7.9
I have an issue with my falling detector ................................................................................................. 18
8
FAQ Frequently asked questions................................................................................................................ 20
9
Warranty and after sale services ................................................................................................................ 23
10 Monthly Tests............................................................................................................................................... 24
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Per FCC Part 15.21, any changes or modification not expressly approved by ABTYS could void the user's
authority to operate the equipment.
Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user's authority to operate the
equipment.
FALL DETECTOR FOR SWIMMING POOL
TRITON™ Pool Alarm
TRITON™ Pool Alarm: TRIT001-US
I
NSTALLATION GUIDE AND USER MANUAL
S
YNOPSIS

FCC REGULATION

Installation and user guide- 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRIT001-US and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Triton TRIT001-US

  • Page 1: Table Of Contents

    FALL DETECTOR FOR SWIMMING POOL TRITON™ Pool Alarm TRITON™ Pool Alarm: TRIT001-US NSTALLATION GUIDE AND USER MANUAL O READ CAREFULLY AND TO KEEP FOR LATER LOOK UP YNOPSIS Introduction – Important Safety Precautions ..................... 2 Checking the package ............................ 3 Quick Start Guide ............................
  • Page 2: Introduction - Important Safety Precautions

    1 Introduction – Important Safety Precautions You just bought a swimming pool alarm TRITON™ and we would like to thank you for choosing our products and service. This alarm meets requirements of ASTM standard F2208e1. This user guide will allow you to install your swimming pool alarm and understand the way it works.
  • Page 3: Checking The Package

    1 fixing kit (screws, washers, tapping inserts and joints) for the main unit 1 fixing kit (screws, tapping inserts and washers) for the remote unit. 1 testing sheet for validation of installation. 1 terms of guarantee. Figure 1 : TRITON Pool Alarm Installation and user guide- 3...
  • Page 4: Quick Start Guide

    Wait for the reset of the product in “ALARM” mode during 20mn max. (The LED starts to blink in green). • Immobilize the TRITON alongside the edge of the pool with the supplied fixation kit. Your device is now operational. (cf. §5.4) UTILISATION All the LED indicate independent states.
  • Page 5: Operating Principle

    4 Operating principle How TRITON™ Works? TRITON™ detects and analyses disturbances. It was designed to detect any fall of an 18+ lbs child into your swimming-pool in the following conditions. It alerts you by triggering the powerful siren after a few seconds.
  • Page 6 NEVER LEAVE THE POOL UNATTENDED IN THIS MODE. To reduce your reaction time, TRITON™ includes a remote alarm system with a radio receiver which can be set up near your living room (or other convenient location). This will also sound a siren in case of fall in the pool.
  • Page 7 - From the “OFF” mode: type any key. Mode which allows swimming. The siren won’t trigger ON while you are swimming. TRITON™ could switch automatically to this mode if it detects too much wind, and therefore monitoring can not be INACTIVE guaranteed.
  • Page 8 Default Signage Default Signage LOW BATTERIES (blinks in red quickly) One low tone sound once in a minute (BURP) HARDER DEFAULTS (the device requires maintenance) (all the LEDs are blinking in three different colors) Installation and user guide- 8...
  • Page 9: Triton™ Installation

    • The proper performance of TRITON™ is not correctly achieved if used in parallel with tarpaulins. • WARNING: TRITON™ is kitted up with a powerful siren (more than 100dB). Please be careful and pay attention to your auditory system during the installation in case of triggering.
  • Page 10: Placing The Batteries

    Check that the access to the command keyboard is convenient and easy. Please take the necessary precautions to ensure that the TRITON™ is at more than a meter away from the filtration system (pushback noses, sluice gate, skimmer, and vacuum cleaner plug), waterfall or any equipment which can locally commove the pool.
  • Page 11: Temporary Installation

    IMAGE 3 : Vue test chute point le + éloigné (coin opposé piscine rect.) During these tests, after any fall, it is necessary to wait for the automatic reset of the TRITON™ before making another one. Depending on the wind and quietness of the pool, this reactivation could take more than 10mn.
  • Page 12: Final Installation

    Make a fall test from the furthest point If the fall is detected within 20 seconds, your installation is complete. Wait for the automatic reset of the TRITON™ before leaving the pool side. Fill in the validation test form and send it to the following address : TRITON™...
  • Page 13: Recommendations For Remote Siren Installation

    Operating principle The remote siren is remotely driven by the TRITON™ via radio frequencies. If a fall is detected by TRITON™ in the pool, the TRITON™ siren and the remote siren will trigger simultaneously. It is impossible to stop the sirens from the remote device. It is imperative to go to the pool, check what triggered the sirens, act if necessary and stop the sirens by typing the password.
  • Page 14 Once the location has been chosen and validated, drill 2 holes with the Ø 0.25 in. drill one on top of the other at 3.5in. of distance. To ease the radio link, it is recommended to place the siren as high as possible on your wall.
  • Page 15: Triton™ Operating Principle

    • For the external cleaning of your device, please avoid using high pressure unit, abrasive brush and/or any tool that can stripe or impair your falling detector. • The proper performance of TRITON™ is not correctly achieved if used in parallel with tarpaulins.
  • Page 16: Automatic Reset

    7.2 Automatic reset Your falling detector keeps on checking the agitation state of the pool. As soon as the pool is sufficiently quiet, after a swim or a strong perturbation (strong wind, upriver swimming system …) your falling detector switches automatically to REACTIVATION mode (the LED blinks in green / red).
  • Page 17: Attenuated Siren Mode

    While TRITON is OFF, a human or another safety system should keep watch of the pool, if in use by children! To stop the device, enter the 3444 code followed by your password (1234 initially). TRITON™ validates by the LED blinking once in green and a high tone sound (PIP) will be heard.
  • Page 18: Replacing The Batteries

    (PIP)) or type any key twice again. (Same signals as for the automatic reset). Please ensure that TRITON™ is activated and monitoring out the pool before leaving it. Otherwise, the highest WATCHFULNESS of a responsible grown-up is mandatory.
  • Page 19 In this case, please contact our after-sale service by phone, mail or email: E-mail : infoconso@safeblue.com Address : TRITON™ Pool Alarm Customer Care SafeBlue c/o Gestrust, 2 rue Thalberg Case postale 1507 1211 Geneve 1 - Switzerland To enable us to give you a quick answer, please give us a short description of the problem.
  • Page 20: Faq Frequently Asked Questions

    8 FAQ Frequently asked questions During the installation QI2. When a 18+ lbs (8kg) body falls in the pool during the tests, my siren triggers after 20 s or doesn’t trigger, why? RI2.1. Your pool has dimensions bigger than 20 x 40 feet or a really special shape. One detector isn’t sufficient.
  • Page 21 If the alarm is in off mode, the alarm will not sound. If the alarm is in attenuated mode, the alarm sound will be quieter than usual and may not be heard. The proper performance of TRITON™ is not correctly achieved if used in parallel with tarpaulins. •...
  • Page 22 • Don't leave pool toys and floats in the pool or around. These may attract young children to the water. • Always keep the pool water clear and clean. • Keep a telephone and list of emergency numbers accessible near the pool to call for help in case of emergency, or to answer the phone without leaving children unattended.
  • Page 23: Warranty And After Sale Services

    Warranty replacement or repair will not extend the 2 years period of warranty. If TRITON™ proves to malfunction due to a defect in materials or workmanship during the guarantee period, ABTYS shall either replace or repair the device (during the immobilization period be sure to increase active monitoring of your pool).
  • Page 24: Monthly Tests

    10 Monthly Tests To control the good performance of your TRITON™, it is mandatory to proceed monthly control tests (see page X) and write down the results on the form below: In case of dysfunction, warn your local reseller without waiting and take the necessary decisions regarding your pool access and it security.