Orbit Controls OC502-t Owner's Manual

Handheld calibrator-multimeter

Advertisement

Quick Links

OC502-t_GBM_21311
HANDHELD
CALIBRATOR-MULTIMETER
OC502-t
Owner's Manual
ORBIT CONTROLS AG
Zürcherstrasse 137
CH-8952 Schlieren/ZH
Tel: + 41 44 730 2753
Fax: + 41 44 730 2783
info@orbitcontrols.ch
www.orbitcontrols.ch

Advertisement

Table of Contents
loading

Summary of Contents for Orbit Controls OC502-t

  • Page 1 OC502-t_GBM_21311 HANDHELD CALIBRATOR-MULTIMETER OC502-t Owner’s Manual ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch...
  • Page 3 Remove the Packing List and verify that you have received all equipment, including the following: Orbit Controls Model OC 502-t Handheld Calibrator. Operator's Manual OC 502-t. If you have any questions about the shipment, please call the Orbit Controls Customer Service Department. NOTE When you receive the shipment, inspect the container and equipment for signs of damage.
  • Page 4: Table Of Contents

    INDEX CALIBRATOR-MULTIMETER OC 502-t page 5 FUNCTION OUTPUTS and INPUTS L C D DISPLAY KEYBOARD SPECIFICATIONS CALIBRATOR – FUNCTION SELECTION Setting of the output current 0 - 22mA in steps or ramps Direct setting of the output current between 0 and 22mA Setting of the voltage output 0-14V in steps or ramps Setting of mV Outputs 0–560mV and 0–28mV in steps or ramps Thermocouple output in steps or ramps...
  • Page 5: Calibrator-Multimeter Oc 502-T

    9 hour uninterrupted operation. Back ground light can be switched on. FUNCTIONS OC502-t can be set for following functions by using the keyboard and the digital display: Tara of the analogue outputs, the filter selection, Range selection 0-28mV or 0-560mV background light.
  • Page 6: Outputs And Inputs

    Calibrator Current Source 0 ... 22 mA Current Sink 0 ... 22 mA Voltage Source 0 ... 14 V mV Source 0 … 28.000 mV and 0 … 560.00 mV DIN Thermometers J, K, N, R, S, T, B, E The calibrator functions are settable with three sliding switches: ON-OFF Power ON and OFF...
  • Page 7: Keyboard

    KEYBOARD SPECIFICATIONS CALIBRATOR Outputs + OUT - Current Source Range 0 ... 22mA, max. Load 750 Ohm Accuracy ± (0.05% from Value + 0.1% from Range) Option: 0 … 110mA, see page 16: OC502-V2-100. Current Sink Range 0 ... 22mA @ max. 24VDC Accuracy ±...
  • Page 8 Resolution 0…22.000mA, 0…14.000V, 0…560.00mV, 0…28.000mV, 0.1ºC ± 25ppm/K Tempco Ramps Raising or sinking Ramps with programmable Steps ± 0.1mA, ± 0.05V, ± 2mV, ± 0.1mV, ± 5 ºC or ± 0.5mA, ± 0.25V, ± 10mV, ± 0.5mV, ± 20 ºC Temperature Working: -10 ºC ...
  • Page 9: Calibrator - Function Selection

    CALIBRATOR - FUNCTION SELECTION The calibrator functions are selectable with three sliding switches. The keyboard permits setting of Ramps, Steps or direct Value entry. The Multimeter is active all the time and can be simultaneously used with the calibrator. The function is described in §...
  • Page 10: Direct Setting Of The Output Voltage Value 0-14 V, 0-560Mv, 0-28Mv And T/C

    Direct setting of the output voltage value between 0 and 14 V, 0-560mV, 0-28mV and T/C Sliding switch set to OUT-V. The key Num activates the numeric selection. Enter the required value with the keyboard and press Enter. To erase the entry, use the keys ← and → . Selection of the display function The key MENU selects following operation modes –...
  • Page 11: Multimeter - Function Selection

    MULTIMETER - FUNCTION SELECTION The multimeter is active all the time and can be simultaneously used with the calibrator. The calibrator output and the multimeter inputs have common GND. The upper part of the display shows the values and parameters of the Multimeter: AUTO Autoranging ±...
  • Page 12: Calibration Of Calibrator

    8.1 CALIBRATION of CALIBRATOR OUTPUTS 8.1.1 Current Output 4-20mA Outputs + OUT - with connected mA-Meter. Sliding switch OUT-I. Press 1. The display shows: With the keys Up or Down appears the calibration constant 0. To change it, enter 11 with Up or Down. The whole constant can be set with the keyboard.
  • Page 13: 8.1.3 Voltage Ranges 0-14V, 0-560Mv, 0-28Mv

    8.1.3 Voltage Ranges 0-14V, 0-560mV, 0-28mV Output Terminals + OUT – with external V-Meter connected. Sliding Switch in Position OUT-V. Set the output voltage 2V with Up or Down and store with Enter. Select 10V Range with Menu, set the calibration Constant with Up or Down and store with Enter.
  • Page 14: Voltage Inputs 200V

    8.2.4 Voltage input 200VDC Inputs GND and IN-V supplied from external voltage calibrator 200VDC. Press 5. The display shows: Short the inputs. Press Enter to store the zero input. Press Menu. The display changes to: Apply 200VDC from external calibrator. Press Enter to store the 200V full range input.
  • Page 15: Tara

    TARE The Tare is active in the Multimeter function and can be used for DC-V and DC-I measurements to set the display to zero. Attention has to be paid when the Tare is set. The entire measuring range has to be considered in order not to overrange the meter.
  • Page 16: Handheld Calibrator-Multimeter Oc 502-V2-100

    √ Rechargeable Battery √ Software calibration Orbit Controls Model OC 502-V2-100 is a Calibrator-Multimeter for generation of 0/4 - 110mA in Source and Sink mode and Voltages between 0 to 11V. External voltages ± 2V, ± 20V and ± 200VDC (firm ranges or Autoranging) and currents up to ±100mA can be measured...
  • Page 17: Calibration Certificate

    1.0000 V 10.000 V 100.000 V 50.000 mA 2.0000 V 20.000 V 200.000 V 100.000 mA Technician ........ORBIT CONTROLS AG Zürcherstrasse 137 QC: ....CH-8952 Schlieren/ZH Tel: +41 44 730 2753 Fax: +41 44 730 2783 Date: ……………………………..info@orbitcontrols.ch...
  • Page 18: Warranty Statement

    We will be pleased to answer all your questions not only to this instrument but also to all our calibrators and measuring equipment. Please call our customer service or write to us info@orbitcontrols.ch Thank you. Orbit Controls AG Customer Service Zürcherstrasse 137 Tel: +41 44 730 2753 8952 Schlieren-Zürich...