  • Page 1 OPERATION MANUAL GPS&GPRS CAR ALARM GT3200ST...
  • Page 2 1.2 Report Setup GT3200ST must be initialized by PC setup program in order to make communication with the remote server /call center. There are seven main sections that allow users to program the device, (1) User detail (Device ID, server IP, and port, SMS number, GPRS APN…) (2) In-built Geofence definition (up to 5 circular, 5...
  • Page 3 User can deactivate the self-Geofence at any time by pressing the button again. If the GPS cannot be located when the Immediate Geofence function is been executed, GT3200ST will used the last known position as the origin of the circular Geofence zone to perform the protection.
  • Page 4 For long periods of inactivity user have the options to set the unit in sleep mode this will enable the unit to save electric power. GT3200ST Can go to sleep mode when ACC goes off, Shock-sensor not be trigger for 5minuts and this feature is configurable. “GPS” can be power off. User can setup the automatically wakeup time during the sleep mode to ensure the device is working.
  • Page 5 During the sleep mode, if any of the inputs are triggered, the system will wake up and send relevant reports to the server. The input triggers for waking the device up are selectable. When ACC is on, the system will back to working mode and stay connected to the TCP/UDP server in GPRS network.
  • Page 6 1. SMS send/receive 2. phone call 3. main unit information display Handset (Optional) 4. Immediate Geofence activate/deactivate 5. Help report sending 6. Duty on/off report 7. Emergency release Initialize the unit and program the device, including Network APN, server IP address, PC-setup user message, report control, and Geogence setting, etc …...
  • Page 7 Anytime the unit can call out and pick up phone call as well. to dial the number directly through the keypad. After dialing the telephone number, press button once or button〝Ⅰ〞of two button valet switch once dial out. If the dialing is successful, HAND FREE will ring, each time the button is pressed, the HANDFREE will chirp once as indication.
  • Page 8: Status Indicator

    (6) Enter code learn mode or exit. ACC on and then press the button (the LED will be temporally stay off) and release it when the LED flashes 4 times. After releasing it, the horn will chirp three times to indicate system entered code learn mode; Turn ACC off to exit code learn mode and there is no sound for indication.
  • Page 9: Main Interface

    B. Version No. Checking The below interface will last until correct UNIT Version No. is checked. (You should run this program before turn on power of UNIT) C. MAIN INTERFACE 1. [User detail:]...
  • Page 10 If the SIM card is password protected, user can input the “SIM PIN” window to set password of SIM Card. IMEI: Any operate with ‘request or request all’ t after GPRS power on, the module series number will display automatically, otherwise it displayed with space. Set UNIT ID and UNIT password of for the device.
  • Page 11 UNIT can save 6000 reports (6000-1) recently; Click ‘Export’ button can export them with Excel or Text format. “Initialize ” button: clear all data in UNIT. Request All: read out the whole existing setting from GT3200ST. Request: read out the setting in the current page. Apply: transfer the setting to GT3200ST in the current pages.
  • Page 12 2. [Geofence:]...
  • Page 13 Four Circular Geofence and one self-geofence: Circular Geofence must set origin and radius: Origin format :N2446.5321E12120.4231; N2446.5321 is latitude, E12120.4231 is longitude. Radius from 0.1 km to 1000km. User can set the reports send or local or ignore: Send: report will send out immediately if generation Local: report will save if generation, it will send out by local network Ignore: cancel reports.
  • Page 14 20 point Geo-fence areas can be set. When UNIT is out of these predefined zones, a report will be generated.
  • Page 15 3. [Local report]: Automatic report can be configured in this section. To activate the function(s), please select “√” in checkbox and fill in data in the textbox.
  • Page 16 The reports will be summarized as (1) Intelligent report Parameters: On/Off, Report time when moving, Report time when stop, and threshold speed. Report when speed less than a preset value (refer the following 1.5 Km/Hr), and it will send stop report after a preset time (refer the following 120Sec).
  • Page 17 (6) AD detect report (AD2) [on/off] SEND REPORT IF ADC2 LESS THAN [min voltage] V for [debounce time] SEC, RESEND PER [resend time] SEC [on/off] SEND REPORT IF ADC2 MORE THAN [max voltage] V for [debounce time] SEC, RESEND PER [resend time] SEC [on/off] SEND REPORT IF ADC2 GO UP [up voltage] V for [debounce time] SEC [on/off] SEND REPORT IF ADC2 GO DOWN [down voltage] V for [debounce time] SEC...
  • Page 18 You can select the crash report to be sent or not, while crash sensor over a preset value.(The crash sensor must be fit up, or the report still be ignored even if you select the item.) Otherwise the report will be ignored. (13) Tilt report Parameters: on/off, and degree If ACC off, then crash-sensor will work (if the Tangent angle sensor connected).
  • Page 19 Special command for SMS mode: If the GT3200ST is not in the GPRS online status, user can send command &&Y02 or &&Y04 to ask unit to connect to server. This command can be sent from any device via SMS;...
  • Page 20 All the roam reports configured are same as Local report. Send: report will send out immediately if generation Local: report will save if generation, it will send out by local network Ignore: cancel reports.
  • Page 21 ACC ON to ACC OFF distance is 5km. Sleep mode (when ACC OFF) (1) GT3200ST can go to sleep mode when ACC goes off and crash-sensor (and optional shock sensor) not be trigger for 5minuts. In sleep mode, GPS will be disabled.
  • Page 22 6. [Roam Alarm REPORT setup] In roam alarm mode, use can set all the alarm reports send or local or ignore: Send: report will send out immediately if generation Local: report will save if generation, it will send out by local network Ignore: cancel reports.
  • Page 23 To send report in local SMS, compressing N reports to a SMS and then send out.(N: the digit between 1~5) To send report in roam SMS, compressing N reports to a SMS and then send out.(N: the digit between 1~5) APPENDIX 1 GT3200ST SPECIFICATIONS Physical Parameters Enclosure dimensions 130*80*25mm Weight...
  • Page 24 Electrical DC Supply voltage 12V or 24V DC Tolerance voltage 9V-36V Current (GPRS online) 60mA Current (GPRS transmission) 80mA Current (Peak) 120mA Current (Sleep) 25mA (GPS off) Internal Battery Battery type Ni-Mh 4.8V Battery capacity 80 mA/H Charge type Built-in charge circuit GPRS* Data provided by SIMCOM Frequency Range (MHz) Support 4-frequency 850/900/1800/1900...
  • Page 25 Storage -40℃ to +85℃ Humidity Non-condensing Input voltage 3.0 to 3.6 VDC Current draw Average acquisition 36mA (typical) Tracking 31mA (typical) Antenna supply via VANT Voltage range Up to 5.2V Max. allowed current 4 50mA Communication GPRS \SMS\RS232\RF (with optional build in alarm) Environmental Operating Temperature -20°C to +55°C...
  • Page 26 OPTIONAL TEMP SENSOR HANDSET OPTIONAL CRASH SENSOR HANDFREE OPTIONAL CRASH SENSOR PC SETUP OPTIONAL EXTERNAL RF ANT RESET GT3200ST GREEN LED: GPS INDICATOR YELLOW LED: GSM INDICATOR RED LED: POWER INDICATOR GPS ANT GSM ANT VALET SWITCH 5A FUSE OPTIONAL...
  • Page 27 15.21 Federal Communications Commission (FCC) Statement You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 15.105(b) Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.
  • Page 28 FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.