MEMORY DELETION ..................... pag 13 DIAGNOSIS MODE ......................pag 14 CARBURATION LEARNING PROCEDURE ..............pag 15 LANDI RENZO S.P.A. reserves the right to make improvements or modifications to its products at any time, at its own judgement and without notice thereof.
When the cursor is in position L []]]]]] R it indicates that the mixture measured by the lambda sensor is LEAN When the cursor is in position L ]]]]]][ R the mixture measured by the lambda sensor is RICH button takes you back to the MAIN MENU page. Pressing the Landi Renzo S.p.A.
FOR CHANGE If in modify value mode you do not want to confirm the figure just varied, pressing the button restores the previous value (fig. 11). 2000 RPM Modify not confirmed by pressing ESC button, fig.11 Programmer tester Mod. V05...
Linear TPS 5-0V: the voltage of 5V indicates throttle closed, 0V the throttle is fully open. SWITCH 0-12V: the voltage of 0V indicates throttle closed, 12V the throttle is fully open. fig.16 SWITCH 12-0V: the voltage of 12V indicates throttle closed, 0V the throttle is fully open. Landi Renzo S.p.A.
INDICATOR SENSOR TYPE fig.17 (fig. 18) LANDI RENZO: select this parameter for all LANDI RENZO sensors, both LPG and CNG. AEB: if an AEB-type LPG sensor is used. O-90W: for LPG indicator sensors that have an internal resistor of 0-90Ω.
By selecting the square wave type of emulation it is possible to set the parameters indicated below (fig. 23); change these parameters only by following the instructions of the LANDI RENZO technical service. HIGH TIME : the time of the signal emulating a rich mixture (fig. 22).
• Check on the road at what TPS value there is irregular carburation and set this value for TPS FOR MAXIMUM OPEN THROTTLE. OPTION ENABLED fig. 27 OPEN THROTTLE POSITION 100 STEPS fig. 28 TPS FOR MAXIMUM OPEN THROTTLE 2.8 V fig. 29 Programmer tester Mod. V05...
The cut-off option must be used only after the central unit has acquired the default position of the linear actuator NOT ENABLED with stepper motor. fig. 33 Landi Renzo S.p.A.
100 steps (fig. 38). Therefore, in the case of resetting, re-enter the parameters that may have been changed and which correspond to the vehicle. 100 STEPS fig. 37 MEMORY DELETION fig. 38 Programmer tester Mod. V05...
If you do not want to complete zeroing the memory of the diagnosis function, press or change “page” with one Diagnosis memory reset page fig. 42 of the direction buttons. SENSOR NOT WORKING Disconnected sensor diagnosis page fig. 43 Landi Renzo S.p.A.
Overlap time (during changeover from petrol to gas) ......... 0.400 sec. Type of TPS (throttle position sensor) ............linear 0-5V Indicator sensor type (gas level) .............. Landi Renzo Lambda sensor type ..................... 0-1V Lambda sensor reading delay ................5 sec.
Page 16
LANDI RENZO S.p.A. via Fratelli Cervi 75/2 42100 Reggio Emilia ITALY Tel. (+39)/0522/382678 -Telex 531050 RELAND - Fax (+39)/0522/382906 E-mail: info@landi.it - Internet Site: http://www.Landi.it SISTEMA QUALITÁ CERTIFICATO Accredited by the Dutch Council for EN 9001/ISO 9001/ BS5750 Certification APPROVED BY BVQI...